Four-wire
-
Product
Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)
HR-480
-
HR-480 industrial residual chlorine meter takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.The sensor(RS-1) combined with uses a galvanic method with no drive section, making it highly maintainable, and producing stable measurements over a long period.
-
Product
Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)
HE-480C
-
HE-480C connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. This is a highly functional model, with high-performance temperature compensation, and is applicable to a wide range of tasks, from managing pure water for use with semiconductors, to managing the quality of boiler water.
-
Product
Electrical Testing
-
Innovative Testing Solutions, Inc.
Our specialty is Direct Current automotive components. We perform product validation and design verification testing on both electrical components and systems. Also, we perform warranty investigation testing and failure analysis. We have voltage capabilities to 300 volts and current capabilities to 1000 amperes. Both two-wire and four-wire resistance measurements are supported from NanoOhms to GigaOhms.
-
Product
Panel-mount Type ORP Meter (Four-Wire Transmission)
HO-480
-
The HO-480 industrial ORP meter is an ORP converter for measuring the oxidation-reduction potential of all types of solvent.Being combined with a lead-free sensor, it makes measurements in a way that is kind to the environment.
-
Product
Field-installation Type Turbidity Meter (Four-Wire Transmission, For Wide Range)
HU-200TB-W
-
HU-200TB-W is a turbidity meter developed to continuously measure turbidity in processes with large turbidity changes, such as water intake and sedimentation tanks in water supply plants. It employs transmission 90-degree scattered light method and is ideal for monitoring changes in processes with large turbidity changes from low range (10 degrees) to high range (2000 degrees). An electric wiper cleaning can be installed as an option, and long-term stable measurement is possible by periodic cleaning.
-
Product
Octal Four-wire Multiplexer
SIM925
-
Stanford Research Systems, Inc.
The SIM925 is an eight input channel, four-wire multiplexer for low-level signal applications. Kelvin-lead measurements are supported with optional buffering of the two sense leads
-
Product
Resistance Measurement
-
PROMET 100 / 200 / 600 high-accuracy, precision ohm meters deliver an adjustable test current up to 600 A which is independent of the supply voltage. They utilize the four-wire resistance measurement method, enabling them to meet extremely stringent accuracy requirements when determining resistance values in the micro-ohm range.State-of-the-art power electronics coupled with a robust design guarantee maximum reliability, even when used as portable devices in switching stations or industrial environments.The modern operating concept, an interface to the test systems of the ACTAS product line and an optional remote control unit make these micro-ohm meters flexible and versatile.
-
Product
Short Circuit Locator
A694
-
The A694 is a short circuit locator designed for fault location in metallic cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A694 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 0.1 ohm and less than 40 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
Product
Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)
HD-200FL
-
Optical dissolved oxygen sensor with no electrolyte replacement and rugged membrane.Highly intelligent, including automatic recognition of membrane properties when replacing the sensor cap.The HD-200FL is an optical (fluorescent) dissolved oxygen meter suitable for monitoring aeration tanks used for sewage treatment, effluent treatment, and other processes. Compared to conventional membrane polarographic type sensors, there is no need for electrolyte (internal fluid) replacement or warming, up. Characteristics of optical sensors are utilized to realize unequaled, improvement in ease of maintenance and reduction in running costs. Moreover, it features enhanced user-friendliness, with sensor caps that have built-in memory and a membrane replacement notification function.
-
Product
Electronic Resistance Store
MPS2
-
The MPS2 module is a mezzanine module designed to form DC resistance in two channels with a four-wire measurement circuit. MPS2 is installed on the mezzanine carrier - the NMU module and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NMU module. The NMU module together with the mezzanines installed on it forms a VXI module of the size C-1 and is used to create information measuring VXI systems.
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
-
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
Product
Resistance Meter
MT16-4L
-
М-module МТ16-4Л is a mezzanine module (hereinafter referred to as a mezzanine), designed to measure the resistance of resistive sensors using a four-wire measurement circuit in sixteen channels (sixteen-channel digitizer). М-module МТ16-4Л is installed on the mezzanine carrier - module НМ-М and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NM-M module. The NM-M module, together with the mezzanines installed on it, forms a VXI module of the C-1 size and is used to create information measuring VXI systems.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Industrial Time sharing Proportional Control)
HP-480TP
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.HP-480TP is a pH meter with a time sharing proportional control function, making it ideal for tasks such as interval processing in any type of control process.
-
Product
Short Circuit Locator for Power Cables
A910
-
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
Product
RS-232 to RS-422/RS-485 Interface Converter
Model 9365
-
FEATURES: DIN Rail Mountable; User Selectable RS-422 or RS-485; User Selectable Two- or Four-wire RS-485; DataSpy® LCD Display; Intelligent Control of RS-485 Transmitter and Receiver; DTE/DCE Compatible; Data Rates Up to 115.2 kbp.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Digital Multimeters
-
*5½-digit resolution to 8½-digit resolution DMMs*6ppm basic voltage measurement accuracy on the 8½-digit DMM for calibration laboratories*Fast, 1 Msample/s sampling speed to capture complex, low level current profiles from IoT devices or other wireless devices*Sensitivity of 1 µΩ and 1 pA to test low power devices for research, design, and manufacturing test*A wide range of measurement functions such as DC and AC volts, DC and AC current, two- and four-wire Ohms, continuity, frequency, period, RTD, thermistor, and thermocouple temperatures, diode test, and capacitance*Numerous interface options including LAN/LXI, USB-TMC, GPIB, and RS-232 for data acquisition and automated testing*Intelligence to execute tests and create customized measurements with minimal PC interaction*Measurement expansion up to ten channels
-
Product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
-
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
SparkFun Load Sensor Combinator
-
The SparkFun Load Sensor Combinator is a bare PCB that combines four load sensors into a standard four-wire Wheatstone bridge configuration. If you open up an electronic bathroom scale, you’ll find a large rat's nest of wires. The Load Sensor Combinator was created to combine the 12 wires found in a bathroom scale into the standard four-wire Wheatstone bridge configuration.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Pulse Proportional Control)
HP-480PL
-
HP-480PL industrial pH meter is a pH meter with a pulse proportional control function, which can drive a pulse pump directly.It connects pH sensor and measures pH and temperature in the sample water.As the HP-480PL has a high injection resolution per pulse, it can be used to control a pulse pump as part of a system for processing involving fine control of pH values, for example controlling the pH values of microscopic or small samples.
-
Product
4-Wire Universal Cable/Harness Tester
LX-850
-
Shenzhen Lian Xin Technology Co., Ltd.
Starting up conducts self-diagnosis and self-correction·The system can scan and direct automatically.·The system provides advanced instant open-circuit, short-circuit, continuity test, can test the wire break·It can function as unilateral, standard, multi-segment and spot test of wire·The maximum test voltage is AC1000V / DC1500V·The system adopts the advanced four-wire measurement, and the minimum measurable range is 1mΩ.·The maximum test spot is 256.·640×480 full Chinese/English large color display .·All varieties of linearity and safety tests are available.·Fully programmable continuous test is available.
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)
HR-200RT
-
HR-200RT is connected to a residual chlorine sensor (RA-30), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents.Stable measurement over a long period was realized by physical polishing cleaning using beads.