Filter Results By:
Products
Applications
Manufacturers
2-wire
resistance measurement method.
-
product
2-Wire Bus Buffers
Renesas' 2-wire bus buffers are designed to improve data transmission speed on SMBus or similar 2-wire serial bus interfaces.
-
product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
PXI Switch - 24-CH 2-Wire Multiplexer Module
PXI-7921
ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix Topology Without Column Protection Resistors
782385-09
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Interface
RAR-PCIE
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Digital Power Recorder
MPR-601W-02
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
Modbus Register Converter
Model 2390
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
product
PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module
780587-29
128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays
M9101A
The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.
-
product
External Temperature for PT100 Probe
TGP-4104
This data logger uses an external PT100 probe to record high temperatures. Probes are available to measure up to 300 and 600C. These are listed in the 'You will also need' section. The PT100 probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
External Temperature for 3-wire PT1000 Probe
TGP-4204
PT1000 probes are available with this logger that will record down to -200C, making them suitable for cryogenic applications. The probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
product
Interface
RCEI-530
Available in a range of configurations to match your needs, the RCEI-530 provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols. The RCEI-530 supports maximum data throughput on all channels while providing onboard message scheduling, label filtering, multiple buffering options, time-tagging, error detection and avionics-level I/O discretes, with support for either 33 MHz or 66 MHz PCI interfaces.
-
product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.
-
product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
product
Interface Technology ProLine
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation Amplifier for DC voltage and current measurement with galvanic isolation, active and passive standard signal isolation amplifier, supply isolation amplifier for supplying 2-wire sensors, transmitter for temperature and AC signals, isolating amplifiers for high voltages and shunt applications. T
-
product
TB-2676, Ribbon, 100 V, PXI Module Multiplexer Terminal Block
779535-01
Ribbon, 100 V, PXI Module Multiplexer Terminal Block - The TB-2676 features ribbon cable headers that help you access all channels of the PXI-2576 Multiplexer Switch Module. You can use the TB-2676 to configure the 16 banks of 4x1 2-wire multiplexers included with the PXI-2576.
-
product
Door Contact Sensor
ENVIROMUX-M-DCS
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
product
LVDT/RVDT Simulation Board
75DL1
The 75DL1 is a cPCI LVDT/RVDT Simulation Board that provides eight 2-wire or four 4-wire transformer isolated programmable outputs. It provides wrap-around self-test, PXI compatibility, optional Excitation Supply, and is available for Military or Commercial applications.
-
product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
product
Isolated RS-485
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.
-
product
RS232 / RS485 / RS422 Isolators/ Isolated Converters
From 3-wire to 7-wire RS232 isolators, 2-wire RS485 to 4-wire RS422 / RS485 isolators, and USB isolators to USB / RS232 / RS485 / RS422 optically-isolated converters, CommFront has all the industrial-grade optical-isolation devices to protect your assets from the unexpected. If off-the-shelf product does not provide enough security for you, we can even tailor-make the devices, which are customizable right down to the nuts and bolts.
-
product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
product
SPMI Protocol Analyzer and Exerciser
PGY-SPMI-EX-PD
Prodigy Technovations Pvt. Ltd.
SPMI Protocol Analyzer (PGY-SPMI-EX-PD) is the Protocol Analyzer with multiple features to capture and debug communication between host and design under test. SPMI (System Power Management Interface) is a MIPI (Mobile Industry Processor Interface) standard with 2-wire synchronous serial, bidirectional interface that connects the integrated Power Controller(PC) of a System on- Chip (SoC) processor system with one or more Power Management Integrated Circuits (PMIC) voltage regulation systems.
-
product
RS-485 and RS-422 Transceivers
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.





























