RS232
A standard interface for serial binary data interchange defining voltage levels for logical one and logical zero, standard transmission speed and connector types.
See Also: Serial Communications, I2C, RS422, RS485
-
Product
ULI-211E - Heavy Industrial RS-232/422/485 (Terminal Block) To Multimode Fiber (ST Connector). Panel Mount Metal Chassis
BB-FOSTCDRI-PH-MT
Terminal Block
Converts serial data signals to multi- or single-mode fiber2 KV, 3-way isolation (input, output, power circuits)Data rate: 9.6 to 115.2 kbps (bit-wise enable)-40 to +85°C wide operating temperatureIP30 metal panel mount case (DIN rail adaptable)FCC, CE, IEC-61850-3, IEEE 1613, UL C1/D2Note: 2 units required to extend data via fiber optic connection (see datasheet)10-48 VDC power source required (not included, sold separately)
-
Product
2-Port RS-232/422/485 Serial Device Server
EKI-1522
-
Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancyProvides COM port redirection (Virtual COM), TCP and UDP operation modesSupports up to 921.6 kbps, and any baud rate settingAllows a max. of 5 hosts to access one serial portAllows a max. of 16 hosts to be accessed as TCP client modeBuilt-in 15 KV ESD protection for all serial signalsProvides rich configuration methods including Windows utility, Telnet console, and Web BrowserSupports 32-bit/64-bit Windows 2000/XP/Vista/7/8/8.1/10, Windows Server2003/2008/2012/2016, and LinuxAutomatic RS-485 data flow controlSupports line to line 2 KV, line to ground 4 KV surge protection
-
Product
High Power Programmable AC Source with Transients
61510
-
Chroma Systems Solutions, Inc.
Power Rating:61511: 12KVA61512: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation
-
Product
4-Port Non-Isolated RS-232, M.2 B Key(2242, USB), DB37 Cable
PCM-34D4R2
-
Meets Advantech iDoor Technology StandardM.2 2242 B Key compliant (USB 2.0)Speeds up to 921.6 kbps for extremely fast data transmissionSupports any baud rate setting (200 bps ~ 921.6 kbps)The PCM-34D2Rx (2-ports) supports Isolated ProtectionCompatible with embedded automation PC UNO-1/2/3/4 seriesCompliant with FCC/CE Class A CertificationOperation temperature 0~60 degree support
-
Product
Isolated USB To RS-232 Converter
ADAM-4562
Digital / Analog Converter
Power from the USB portHot swap function supportedIsolation protection 3000 VDC providedAutomatic RS-485 data flow controlTransmission speed up to 115.2 kbps
-
Product
Annunciator
Series 90B
-
Dual independent communication ports (RS-232/485 and Ethernet) are available to transmit alarms to other devices. The Series 90B can receive alarms using communication ports, eliminating the need to connect digital inputs and associated wiring. The Series 90B supports Modbus, DNP and ASCII protocols.
-
Product
UV Fluorescence Sulfur Dioxide Analyzer
Model T100
-
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
Product
1-Port RS-232/422/485 Serial Device Server
EKI-1521
-
Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancyProvides COM port redirection (Virtual COM), TCP and UDP operation modesSupports up to 921.6 kbps, and any baud rate settingAllows a max. of 5 hosts to access one serial portAllows a max. of 16 hosts to be accessed as TCP client modeBuilt-in 15 KV ESD protection for all serial signalsProvides rich configuration methods including Windows utility, Telnet console, and Web BrowserSupports 32-bit/64-bit Windows 2000/XP/Vista/7/8/8.1/10, Windows Server2003/2008/2012/2016, and LinuxAutomatic RS-485 data flow controlSupports line to line 2 KV, line to ground 4 KV surge protection