Earth Continuity
Verifies ground is present.
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
product
TEST BOX
6280 TB
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
product
Multifunction Earth Tester
MT-100
Multifunction earth tester for measuring earth resistance, continuity of protective conductors’, with touch-screen display and integrated Wi-Fi
-
product
Earth Resistance & Resistivity Meter (for 50Hz mains)
MRU-120
* earth resistance measurment with 3-pole,4-pole method, * earth resistance measurement without disconnecting measured earths (using clamp), * continuity of equipotential bondings and protecting conductors * two clamps earth resistance measurement without auxiliary test probs, * earth resistivity measurement,
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.
-
product
PAT and Installation Verification Unit
PowerCheck 1557
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
product
Multifunction Meter for Electrical Installations
AMPI-530
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
product
Multifunction Electrical Installation Meter
AMPI-520
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
Earth Leakage Relay
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
product
PAT Check Box
369A910
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
product
Earth and Resistivity Testers
Earth tester offering selective earth, soil resistivity, earth coupling and continuity measurements
-
product
Earth Bond Test Set
EC-12
The Earth bond test is a basic safety test prescribed in many standards to test samples for the integrity of earthing continuity throughout the sample.
-
product
True RMS Digital Insulation Multimeter
Model KM 877
Kusam Electrical Industries Limited
• VFD V & Hz readings.• Paper White Backlight LCD Display• Record MAX / MIN readings.• Display Hold Function.• Dual Digital Display.• PI & DAR Function.• Autoranging.• Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values.• LOCK-Test mode for Insulation Resistance & Earth Continuity Test.• BeepJack ™ audible & visible input warning.• Remote Probe for insulation Resistance & Earth Continuity Test.• Functions : DC/AC Voltage , VFD AC Voltage, Insulation Resisitance, Resistance, Earth Continuity Test, Hz Line Level Frequency
-
product
Manual PAT Testers
If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.
-
product
Voltage & Continuity
A voltage continuity tester is another way to determine if a circuit breaker needs to be replaced.
-
product
Earth Testers
Kyoritsu Electrical Instruments Works, Ltd.
Earth Ground Testing. Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
product
Earth Leakage
Earth leakage is when the current flowing in a system finds an alternative return path other than active and neutral conductors.
-
product
Measuring Earth Resistance
OSP-510
Additional equipment to measure the earth resistance and soil resistivity AD-510.
-
product
Earth Testers
Sanwa Electric Instrument Co., Ltd
Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
product
Generator & Earthing Series
Kvtester Electronics Technology Co.,Ltd
AC Impedance Tester is the newly developed enhanced impedance tester on the basis of improving and perfecting the old model product. The instrument has three new functions: equipped with rotating mouse to achieve easier operation; display and print AC impedance characteristic curves; achieve data download and editing the test report with PC online. This instrument adopts the most advanced high-speed microprocessor with more powerful function and better performance. It is well established for its high reliability, simple operations, high accuracy and lightweight. Currently the instrument is in leading position in china.
-
product
Continuous delivery Analytics
Dynatrace tracks every build moving through your delivery pipeline, every operations deployment, all user behavior, and impact on your supporting infrastructure. Through analytics and artificial intelligence you can start building what users want, remove what’s not needed, and optimize the remaining system to be lean, agile, and innovative.
-
product
Continuous Water Analyzers
The ability to continuously and accurately measure water quality is a key requirement in many processes. Our trusted range of water analysis solutions provide real-time data on process conditions that can be used to improve efficiency, tighten performance and safeguard quality.
-
product
Continuous Testing
Continuous testing is the practice of embedding quality through every phase of the software delivery lifecycle - from planning to production. The goal is to ensure that testing continuously reduces risk and improves application quality.
-
product
Enterprise-Level Continuous Validation
TrustZero
Backed by continuous monitoring, TrustZero is a cloud-based tool that provides enterprise-level continuous validation for PACS. It works in conjunction with CertiPath’s popular TrustMonitor™ credential validation platform, which performs 24/7 Continuous Diagnostics and Mitigation (CDM) for the PKI trust fabric. Whether an organization has one PACS or several, TrustZero provides a single network location to respond to all validation queries for all credentials within a trust federation. When paired with TrustMonitor Enterprise, it can provide this same validation for credentials issued by local trust CAs for intranets, internal networks, VPNs, non-person entities, Internet of Things (IoT) devices, and other items that are issued certificates from private CAs.
-
product
Continuity Tester
69133
Quickly reveals shorts or broken circuits in all types of electrical devices and controls.Tests for continuity of circuit with power off.Bulb in handle glows when circuit is complete (bulb included).Pointed 3-3/4'' (95 mm) probe gets right to the problem.Deluxe 4'' (102 mm) long handle with removable nylon cap holds replaceable bulb and battery.36'' (914 mm) test lead with alligator clip.Uses one AAA battery (not included).Replacement bulb (Cat. No. 69131)
-
product
Earth Ground Testers
TES Electrical Electronic Corp.
Capable of measuring earth voltage. Data hold function. Auto power off function. The timer operates automatically about 10 minutes with the "test button switch are pressed to keep the tester power on.
-
product
Continuous Testing Platform
BlazeMeter
BlazeMeter was designed and built by engineers who are passionate about open source. From mobile to mainframe, IDE or UI, bring teams together in a single platform with shared visibility, tests, and reports.
-
product
Multifunction Earth Tester
MT-200
Multifunction earth tester for measuring earth resistance, protective conductors’ continuity, insulation up to 1000V, with touch-screen display and integrated Wi-Fi
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.