Temperature Calibration Baths
-
Product
Calibration Baths
-
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
-
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
-
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
784788-01
-
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
7-Meter Laser Head Cable
10882B
-
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Thermistor Temperature Probe
E2308A
-
The Keysight E2308A is a general purpose temperature probe. The thermistor (5 k ohm at 25 degrees C) is encapsulated in a stainless steel case and typically used for liquid temperature measurements.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
-
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
-
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
-
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
-
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
-
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Air Temperature Probe
U1183A
-
Measure dryer, transport pipe, and surrounding air temperature within the range of -50°C to 800°C.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
-
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
-
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Thermocouple (J-Type) And Temperature Probe Adapter
U1185A
-
The U1185A consists of a thermocouple bead (J-type) and a mini connector to dual banana plugs.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
-
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Industrial Surface Temperature Probe
U1182A
-
Measure still surface temperatures within -50°C to 400°C; works with handheld clamp meters, DMMs, scopes, and calibrators.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
-
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
-
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
1 Mm Calibration Kit
85059B
-
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
-
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
-
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
-
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
USB-TC01, 1-Channel Temperature Input Device
781314-01
-
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
-
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit





























