Discharge
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Capacitive Discharge Testers
-
For IEC Testing of residual voltage after plug disconnect. The CDT-240 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results. Scope output for viewing decay waveform. Presets for EN 61010, EN 60065, EN 60950, EN 60601-1 and EN60335. Recommendations for Pluggable Type B equipment. NIST calibration supplied; A2LA calibration available. 16A option for testing large equipment.
-
Product
Battery Charger-Dischargers & Monitors
-
It is a compact and multi-functional unit with three major functions: battery charger, battery discharger and battery activator. These three functions could be used individually or comprehensively to facilitate your daily work for battery maintenance. JUNXY single battery regenerator could be applied for different cell voltages, such as 2V, 6V & 12V single cell battery regenerator, while JUNXY battery string regenerator covers 24V, 48V, 110V, 220V battery strings with different charge/discharge current selectable.
-
Product
2 Channel Charge-Discharge Module 6 V, 100 A
BT2205A
Charge-Discharge Module
The BT2205A is a 2 channel charge-discharge module 6 V, ± 100 A, 437.5 W for module Li-ion cell formation and lifetime cycling solution.
-
Product
Three-Pole Lighting And Surge Arrestor
PIVM12,5-275/3+0 Vseries
-
PIVM12,5-275/3+0 Vseries is a three-pole lightning and surge arrester Type 1+2 according to EN 61643-11 and IEC 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building. The use of the lightning current arresters PIVM12,5-275/3+0 Vseries is mainly in the power supply lines, which are operated as TN-C system. The main use of PIVM12,5-275/3+0 Vseries arrester is in structures of LPL III – IV according to EN 62305 ed.2. The marking M specifies a type of construction with removable module.
-
Product
Electrical Safety Multi-Analyzer
TOS9300 Series
-
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
16 Channel, 12-Bit Analog Input PCI Card
PCI-AI12-16A
-
Model PCI-AI12-16 is a multifunction, high-speed, analog-to-digital converter board for use in PCI-Bus computers. It accepts up to 16 single-ended or eight differential inputs. The board uses a low-noise, multilayer printed circuit board. Inputs are protected against overvoltage conditions up to ±35 volts and typically survive static discharges beyond 4000 volts.
-
Product
Miniature, Battery Powered, Stand Alone Pressure and Temperature Data Logger
PRTemp101A
-
The PRTemp101 is a miniature, battery powered, stand alone pressure and temperature data logger. This is an all-in-one compact, portable, easy to use device that will measure and record data for up to 8,191 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged.
-
Product
Load Banks
BD Series
-
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
Product
Measuring & Analysis Equipment
-
Quality management for semiconductor manufacturing processes and liquid crystal panel manufacturing processes, which require nano-order precision. Oxygen analyzers used in firing furnaces and N2 reflow ovens.Water quality meters used to monitor the water quality of plant discharge and the pure water used in semiconductor manufacturing processes.Our measuring and analysis equipment is used in a wide range of fields.
-
Product
Cable Identifiers
-
*Identifies matching phase on long deenergized and discharged conductors*50VDC test voltage enables identification of up to 5,000 foot-long conductors*Compact, lightweight and easy-to-use solution*Versatile for overhead and underground applications
-
Product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
-
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
Product
PD Monitoring systems
TECHIMP PD Hub™
-
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
Product
Analyzers
BA500 Series
-
The BA500 analyzers are high performance battery analyzers with charge and discharge capabilities. The analyzers connect to your computer via USB and the BA500WIN software program is used to control the analyzer and battery under test. This system has a fast data collection system allowing you to collect and view as much data as required. Once you collect this data you can graph, analyze & save it.
-
Product
Battery Load Banks
-
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
Product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
-
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
Product
Corona Effect Camera
CoroCAM 7
-
The CoroCAM 7 corona effect camera is a camera used to visualize and locate corona and electric arc discharges. This camera shares the same ultraviolet imaging system as coroCAM 6D, but additionally combines it with a high-performance visible camera and viewfinder. This camera is used for high voltage inspections.
-
Product
Industrial Battery Tester
-
The Industrial Battery Tester (IBT) has been designed for testing traction batteries or batteries for stationary applications. It can also be used for testing other types of batteries. The IBT performs charging and discharging in accordance with the programmed test schedule. Parameters are constant current, constant voltage, constant resistance and constant power.
-
Product
PCIe Digital I/O Board, 64 Optically Isolated I/O Channels, 24V
APCIE-1564
-
32 digital inputs, 24 V, isolated16 interruptible inputs32 digital outputs, 24 V, isolated, 10 to 36 V, 500 mA/channelOptical isolation 1000 VWatchdog for resetting the outputs to "0" (when Power-On)Protection against fast transients, overvoltage, electrostatic discharge and high-frequency EMIInputs: voltage reversal, input filtersOutputs protected against short circuitOvertemperature and overvoltage protectionDiagnostic report in case of short circuits, overtemperature, voltage drop ...24 V power outputs with protection diodesShutdown logic when the external supply voltage drops below 5 V
-
Product
Automotive & Industrial Cycle Testing System
CV
-
The CV is Bitrode's economical cycle life test equipment for the network based line of battery laboratory equipment. Designed to work with VisuaLCN Lab Client software, the CV provides standard or fully customized charge, discharge and rest cycles for automotive and industrial batteries. The Model CV is also useful for reserve capacity and charge acceptance testing with recharge.
-
Product
PCIe Digital I/O Board, 16 Optically Isolated I/O Channels, 24V
APCIE-1516
-
8 digital inputs, 24 V, isolated15 interruptible inputs8 digital outputs, 24 V, isolated, 10 to 36 V, 500 mA/channelOptical isolation 1000 VWatchdog for resetting the outputs to "0" (when Power-On)Protection against fast transients, overvoltage, electrostatic discharge and high-frequency EMIInputs: voltage reversal, input filtersOutputs protected against short circuitOvertemperature and overvoltage protectionDiagnostic report in case of short circuits, overtemperature, voltage drop ...24 V power outputs with protection diodesShutdown logic when the external supply voltage drops below 5 V
-
Product
Field Strength Meters
FIM-22 And FIM-41
-
The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.
-
Product
Partial-discharge Detection System
GDYT Series
-
GDYT series include partial discharge power frequency testing transformer(YDTW),partial discharge detector(GDJF2008),Isolation filter frequency doubling power device(GDSF-81G) and power frequency withstand voltage control table(GDYD table).It widely used in electrical manufacturing,power operation departments, research institutes and universities.
-
Product
Battery Discharge and Charge Tester
-
HD Power Test Equipment Co.ltd
Battery Discharge Charge Tester is mainly used for the charge test of the lead-acid battery of the backup power supply in the telecommunications, mobile, substation, railway transportation and pertrochemical industry power DC industries. It can proceed the discharge and charge for the batteries to extend the lift-time.
-
Product
Digital (1kV below) Insulation Tester
1161 IN
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Waterproof design, protection class : IP54.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function● BS 16 edition.
-
Product
RiverRay ADCP
-
Teledyne Marine RD Instruments
Go straight to work collecting highly accurate stream and river discharge data with the RiverRay Acoustic Doppler Current Profiler (ADCP).
-
Product
Advanced Data Acquisition And Control System
ADACS
-
This high-speed damage-control system was built around Arc Fault Detect and Continuous Thermal Monitoring (AFD/CTM) from the Johns Hopkins Applied Physics Laboratory. When AFD/CTM detects dangerous arc faults — powerful discharges of electricity between conductors — the ADACS system immediately cuts power to the affected circuit before it can damage equipment or injure nearby personnel. Altogether, the system prevents loss of life, preserves countless repair dollars and assures continuous readiness.
-
Product
Static Grounding for Process Plant & Equipment
Earth-Rite MULTIPOINT II
-
The Earth-Rite® MULTIPOINT II is a unique multi-channel static grounding system that can monitor the simultaneous grounding of up to eight (8) individual pieces of equipment at risk of discharging electrostatic sparks.
-
Product
Electrostatic Products
-
We offer electrostatic measurement instruments for electrostatic discharge (ESD) and high-performance applications. Select from our reliable electrostatic sensors and detectors, voltmeters, charge plate monitors, and surface resistance/resistivity meters.
-
Product
DC Electronic Load
EE30141A
-
The EE30141A DC Electronic Load / Works @ 0.0 Volts Input & real time I/O control. attach the electronic load block to a heat- sink and your up and running. used them with D to A's, A to D's, Pots, PLC's to control the current. These Electronic Loads can be used for both Discharge & Charging Batteries & Devices