Conversion
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
product
Scalar Mixer/Converter Measurements
S93082B
The S93082B scalar mixer/converter measurements enables the highest accuracy for scalar conversion–loss/gain measurements with a simple set-up and calibration
-
product
PMC Analog Out Board
MS 1821
*Bus Interface:- 32 Bit PCI Bus with PMC Interface*Speed of operation up to 66MHz*Spartan-3AN FPGA based design*32 channel single ended analog Output*Unipolar or bipolar voltage output*Programmable output voltage: 0-5V, 0-10V, 0-10.8V, ±5V, ±10V, ±10.8V and is capable of driving up to +/-20mA*16 bit Resolution*Conversion time 10usec typ*Over current protection*Driver interface for Windows2000/XP/VISTA and LINUX OS*Self Test future
-
product
LilyPad Temperature Sensor
Detecting temperature changes has never been easier. The MCP9700 is a small thermistor type temperature sensor. This sensor will output 0.5V at 0 degrees C, 0.75V at 25 C, and 10mV per degree C. Doing an analog to digital conversion on the signal line will allow you to establish the local ambient temperature. Detect physical touch based on body heat and ambient conditions with this small sensor.
-
product
Automotive Conveyor Control
Convey-O-Track
Computer Conversions Corporation
Computer Conversions' Convey-o-Trak Series are standalone precision Conveyor Drive Positioners, designed specifically for assembly-line applications. They serve as a reliable means of precisely positioning conveyors in a truly closed loop system that can be either: exactly job/product rate synchronized position (Line Setters), or, absolute position synchronized to any adjacent conveyor (Synchronizers).
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Cable Tester, HDMI Cable, Handheld, Height 102mm, Width 95mm, Depth 27mm
72-13550
*HDMI cable tester with LED status display*Tests for normal/short/open/crossover circuit*Scan/full display testing modes conversion*Single key operation*Manual/auto power off (after 10 minute inactivity)*Low battery indication < 7.2V*HDMI/HDMI-mini interface*9V battery (6F22)*12-month limited warranty *view Terms & Conditions for details
-
product
1 GHz 60 V Common Mode Differential Probe
DL10-HCM
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
product
Robotics and Machine Vision Standards
Accuracy in machine vision systems is critical to achieving strategic goals regarding quality, efficiency, and consistency. Use our ACCUplace product lines to calibrate vision systems’ distortion, placement/alignment, or other field parameters in systems used for guidance, identification, gauging, and inspection. Using our specialized ACCUedge® technology, our Robotic and Machine Vision Standards are manufactured with line-edge quality that is second to none in the industry, providing the precision needed to calibrate almost any system. Should you need to alter feature patterns, size, or substrate to fit your needs, fill out our Optical Components and Standards form to start the conversation.
-
product
4-CH 10/12-Bit 20 MS/s Simultaneous-Sampling Analog Input Cards
PCI-9812
ADLINK’s PCI-9812 and PCI-9810 are 4-CH, 10 or 12-bit, 20 MS/s simultaneous-sampling analog input cards. The high-speed analog input channels are single-ended, with hardware programmable input ranges of ±1 V, ±5 V and input impedances of 50 Ω, 1.25 k Ω and 15 M Ω. The onboard 32 k-sample A/D FIFO can buffer so data throughput is less than 100 Mbytes/s, the FIFO performs as the temporary A/D sample buffer, and as a rule of thumb, no data loss will occur. When four channels operate at 20 MS/s simultaneously, each sample generates two bytes, resulting in 160 Mbyes/s (4 channels * 20 M * 2 bytes) throughput, which exceeds the peak 132 Mbyte/s bandwidth of PCI bus. To avoid data loss, the 32 k-sample FIFO is the limitation of sample count. In addition to the onboard 40 MHz time base, users are able to supply the external time base in either sine wave or digital forms. The PCI-9810 and PCI-9812 also feature external digital trigger and programmable analog trigger, thus the conversion start point of multiple cards can be synchronized to external events. The trigger modes include software-trigger, pre-trigger, post-trigger, middle-trigger and delay trigger, further expands the capabilities of these high-speed devices. ADLINK"s PCI-9812 and PCI-9810 deliver cost-effective and reliable data acquisition capabilities and are ideal for vibration testing, image digitizing, ultrasonic measurement, biomedical research, ATE and other high-end industrial, scientific, and military applications.
-
product
Optical Access
CXR offers a choice of conversion and optical transport Ethernet or TDM streams, and CWDM optical multiplexing.
-
product
GPIB-RS232, Instrument Control Device
779732-10
The GPIB‑RS232 is an IEEE 488 controller device for computers with an RS232 port. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS232 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS232 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488 and RS232 standards, as well as interpret and execute high-level commands from the serial port, including RS232‑to‑GPIB and GPIB‑to‑RS232 protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
product
Mezzanine System Carrier
MMS8010 / MMS8011
The Abaco ECM 3U VPX carrier supports up to six Abaco Systems Electrical Conversion Modules (ECMs) in a VITA 46 VPX form factor. Each ECM site connects 32 single-ended 3.3 V signals to the FPGA. The specific ECM board installed on a site converts the FPGA signals to 16 I/O signals, for a total of 96 I/O signals across the six ECM sites.
-
product
Portable Winding Resistance Tester
1. Handheld winding resistance meter2. Conversion function for standard temperature resistance.3. 500 test data can be saved and download by flash disk.4. Temperature testing function.
-
product
Transducers
A device that enables conversion between two different forms of energy thanks to its inherent properties.
-
product
Precision Low Power FGA™ Voltage References
ISL60002
The ISL60002 FGA™ voltage references are very high precision analog voltage references fabricated on Renesas' proprietary Floating Gate Analog technology and feature low supply voltage operation at ultra-low 350nA operating current. Additionally, the ISL60002 family features guaranteed initial accuracy as low as ±1.0mV and 20ppm/°C temperature coefficient. The initial accuracy and temperature stability performance of the ISL60002 family, plus the low supply voltage and 350nA power consumption, eliminates the need to compromise thermal stability for reduced power consumption making it an ideal companion to high resolution, low power data conversion systems.
-
product
Precision Voltage to Current Converter
64-VCC
The 64-VCC precisely converts voltage to current. The unit can be placed in-line with a data acquisition system to achieve outstanding conversion accuracy for precise movements in valves or motors. The unit includes a unique current feedback measurement output to precisely monitor actual current in critical applications.
-
product
Portable Hardness Tester
Sinowon Innovation Metrology Manufacture Ltd.
◆ Metal shell, nice appearance design.◆ Available to save 2000 groups test results.◆ Support hardness conversion among HRC, HRA, HRB, HV, HB, etc, can convert 2 different scales simultaneously.◆ 4” LCD to display hardness result, conversion results, Max, Min,Mean value;◆ Support blue tooth printer, with RS232 to connect computer for software running;◆ Can test all kinds of metal which more than 5kg;◆ Indicating error ±5HLD, conform standard ASTM A956;◆ Support 7 types of impact devices.
-
product
Automated Test Systems
Chroma Systems Solutions, Inc.
From power conversion to battery to electrical safety, our test systems will maximize your time, improve your validation process, and increase your throughput.
-
product
2 to 8 Channel Anti-Alias Low-Pass Filter Card
AAF-1
The AAF-1 is a multi-channel anti-alias low-pass filter board designed for front-end signal conditioning in PC-based or stand-alone 12-bit A/D conversion systems.
-
product
Analog I/O module with 32/16 multiplexed analog input channels
IO102
Fast 16-bit analog module with 32/16 multiplexed analog input channels and 4 analog output channels. This I/O module offers lower input sampling and conversion times than the IO101 and therefore leads to smaller overall driver latency time. It is similarly priced as the IO101 but comes with 4 analog outputs instead of 8.
-
product
AC Resonant Test System for Cable
HTXZ / 130
Wuhan Huatian Electric Power Automation Co., Ltd.
Portable frequency conversion resonance voltage test device for domestic cables.
-
product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
product
Quad 250Msps, 16-bit ADC FMC
ADF-Q25
This FPGA Mezzanine Card (FMC) converts four channels of up to 900 MHz analog input bandwidth at 250 Msps and 16-bit resolution. Based on the VITA 57 specification, the ADF-Q25 enables direct coupling of unparalleled analog-digital conversion capability with the VME/VXS/AMC/VPX/PCI-E carrier board of your choice. DEG engineers have designed this product and associated HDL firmware to work with both Altera and AMD FPGAs.
-
product
ARINC 818 to HDMI Converter
The ARINC 818 to HDMI converter is a rugged standalone module available in half-length PCIe form factor used for ARINC 818 to HDMI conversion, HDMI to ARINC 818 conversion, 2x ARINC 818 Switch as well as ARINC 818 Duplicator/Splitter. It is a video Converter module designed with Kintex-7 FPGA, using an Analog device Video Encoder, and Decoder to provide video interfacing requirements.
-
product
Solar Analyzers
Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power
-
product
Milliohm Meter
16502
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
product
Optical Extended CAN Bus Jumper
EOFL-C
Optical Extended CAN Bus Jumper, using fault tolerant to optical conversion to extend the range, can extend up to 5 kilometers subsea.Qualified repeater housing protected on each side by highly reliable glass to metal sealed penetrators.
-
product
Sample And Hold Converters
A critical part of most data acquisition systems, Renesas offers several sample and hold amplifiers for general purpose and military and defense applications that include precision data acquisition systems, synchronous sampling, wide bandwidth analog-to-digital (A/D) conversion, auto-zero circuits, digital-to-analog (D/A) converter deglitching, peak detection, and high-speed DC restore.
-
product
Autocorrelator
Our autocorrelator is designed for those who do not require the sophisticated pulse characterization provided by our FROG Scan systems. Mesa Photonics' autocorrelators are built around the same advanced servo motor used in our FROG Scan systems and can be upgraded later to a complete FROG Scan or FROG Scan Ultra by purchasing a conversion kit. The servo motor precision corresponds to 1 fs temporal steps.





























