Potential Transformer
a type of intrument transformer enabling secondary connected metering.
-
product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
product
Testing of Voltage Measuring Transformers
In this category you will find components for high-voltage testing as well as for testing electronic or conventional voltage measuring transformers.
-
product
Automatic Transformer Test System
TH2829AX
Changzhou Tonghui Electronic Co., Ltd.
*Number of Test PIN: 20*Frequency: 20Hz-200Hz, Resolution: 0.5mHz*Signal Level: 50mV-2Vms (Option 2nv-10Vms)*Test Speed: max 13ms
-
product
Transformer Turns Ratio Tester
CX-BY
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
product
Transformer DC Winding Resistance Tester
HTZZ-100A / 248
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
Current Transformers & Bushings
Measurements International Ltd.
AC Current Transformer, Reference Standard for the Calibration of Precision CTs, Currents as high as 10,000 A, Portable with carrying handle for smaller CTs, Wheels on heavier CTs, Passive or Electronically Aided Compensation.
-
product
Current Transformers
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
product
Transformer Turns Ratio Tester
CXBC-901
Shenzhen Chuangxin Instruments Co., Ltd.
Transformer Turns Ration Tester is applied to measure the voltage ratio and group testing of the three or single phase transformer. All the test results could be printed by the micro printer or saved in the tester.
-
product
Software For Transformer Measuring Lite
T-Base Lite
T-Base Lite is intended for users preferring simplicity over complexity of the Pro version. It is limited to the basic functions of USB interface, data import, data export, synchronization, and automatic firmware updates. Data can be exported in many popular data formats such as Excel, Word, text, .csv, .xml, Crystal reports, and .html. Measurements can be saved as archive files and imported into the database of the T-Base Pro version.
-
product
Transformer Performance Tester
6691
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
product
Transformer Testing
Haomai Electric Power Automation Co.,Ltd.
1)Test Standard:IEC60076 & IEEE C57.12.90 2)Voltage ratio measurement of transformer 3)Turns ratio measurement of transformer 4)Group vector measurement of transformer
-
product
Transformer Short Circuit Impedance Tester
JYW6300
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
product
Current Transformer
LTTJ
Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs
-
product
Current Transformer Field Test Set
1043
The Catalog 1043 Current Transformer Field Test Set is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the Customer's service and while the load is on.
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
Transformer Testing And Monitoring
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
product
Transformer Loss Measuring Bridge
MLS 7100
The MLS 7100 transformer loss measuring bridge was especially designed to greatly simplify the determination of transformer core and copper losses – an ideal choice when working on site. The measuring bridge features open circuit as well as short circuit measuring. Many transformers can be directly connected to the MLS 7100 without needing further transducers.
-
product
Current And Voltage Transformer Test Set
iCT1
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
product
Transformer Oil Acidity Testing Kit
NMC Brand Transformer Oil Acidity Testing Kit used to measure the Acidic content of Transformer Oil
-
product
TRANSFORMER WINDING RESISTANCE METER
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
-
product
Transformer Rated Pre-Wired Meter Enclosures
TESCO Transformer-Rated Pre-Wired Meter Enclosures are built with the TESCO tradition of quality and durability. TESCO enclosures are designed for use in commercial and industrial metering installations where voltage ratings of 480 and above are required. The enclosures are available with ringless, single piece or two piece covers and can be pre-wired between the test switch and socket to meet your exact specifications.
-
product
Low Frequency RF Impendence Transformers
0 kHz to 3 MHz 100W - 4000W 1 input, up to 7 outputs Step-Up / Step-Down Transformers Impedance matching outputs from 1.2 Ohms to 2500 Ohms Compact Design Compatible with T&C''s Class A 10 kHz - 20 MHz LF Generators & Amps Compatible with Class B 20 kHz - 6 MHz LF Generators & Amps
-
product
AC Test Transformer
Shanghai Guantu Technology Co., Ltd.
How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.
-
product
Fully Automatic Transformer Turns Ratio Tester
DY100
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
product
BDV Transformer Oil Test Sets
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.
-
product
Zeta Streaming Potential
ZETA-check
Particle interface potentials like the oscillating zeta streaming potential measured in the ZETA-check, represent the level of electrostatic repulsion between particles. The potential is generated by ionic end groups on particles and macro-molecules, respectively. With ZETA-check, the state of the actual charge of dispersions and macromolecular solutions is obtained within seconds. Solutions and dispersions from 0.3 nm up to 100 µm particle size qualify for measurement.
-
product
GDGS Transformer Power Factor And Tan Delta Tester
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester