Resistance
that which keeps current from flowing freely.
See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Multi-purpose Textile Flammability Tester
TESTEX Testing Equipment Systems Ltd.
Multi-purpose Textile Flammability Tester, to determine the flammability resistance of textile fabrics and for the flammability test of toys and toy material. Multi-purpose Textile Flammability Tester complies with ISO 6940 (1995&2004) / 6941 (1995&2003), ISO 15025, EN71-2, etc. Please contact us for more information about flammability test method.
-
product
Battery Electrical System Analyser
We invented the “Resistance method” which uses a series of shorting pulse to measure the voltage drop in order to calculate the plate’s internal resistance. Unlike other patented “Conductance method” which generates an AC pulse across the battery terminal to measure impedance.
-
product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25T-6.5
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Environmental Control System (ECS) Tester
H301
The H301 Environmental Control System (ECS) Tester measures and displays parameters required to test and troubleshoot aircraft heating and air conditioning systems. These parameters include temperatures, pressures, AC and DC voltages, DC currents, and resistances.
-
product
PXI/PXIe High Density Precision Resistor Module, 9-Channel
40-297A-035
The 40-297A-035 (PXI) and the 42-297A-035 (PXIe) are 9-channel programmable resistors with a range of 2 Ω to 102 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
Concrete Surface Resistivity
Surf
Giatec Surf™ is a laboratory test device for rapid, easy and accurate measurement of the surface electrical resistivity of concrete based on the four-probe (Wenner-Array) technique. The Surf™ patented technology automatically measures resistivity around the concrete specimen using four channels of 4-probe array (located at 90° from each other). The PC software generates the required reports according to the standard specifications.
-
product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25H79-8
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25I40-8
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25T1-6.5
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
P2262A General Purpose Probes
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
PXI/PXIe High Density Precision Resistor Module
42-297A-133
The 40-297A-133 (PXI) and the 42-297A-133 (PXIe) are 4-channel programmable resistors with a range of 2 Ω to 52.4 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
200 A HIGH-CURRENT MICRO-OHMMETER
MPK-203x
The MPK-203x high-current micro-ohmmeter is a portable, microprocessor-controlled instrument. Has optimized filters and protections for measurements in electrical substations. Can be used to accurately measure very low contact resistances of high voltage circuit-breakers and switches, busbars, etc., with test currents up to 200A. It employs the 4 terminals-method (U/I measuring principle) to avoid errors caused by test leads and their contact resistances.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
PXI Dual 16x8 Matrix, 1 Pole Switching
40-532-021
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Pressure Cooling Elements
Rugged cooling elements with corrosion resistance that allow your pressure measurement devices to operate accurately at high pressure and temperature conditions.
-
product
Test System
ITC57300
The ITC57300 Dynamic Parametric Test System mainframe accepts Test Heads that perform nondestructive transient measurements on semiconductor devices such as Insulated Gate Bipolar Transistors (IGBT), power MOSFETs, diodes, and other bipolar devices(requires additional optional bias power supplies and custom personality boards). Included in the mainframe are all test equipment and software necessary to analyze and perform resistive and inductive switching time, switching losses, gate charge, Trr/Qrr, and other transient tests.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
AC-DC High Voltage Power Supplies
These modular High Voltage supplies may be used as constant voltage or constant current sources. They may be remotely programmed by means of either voltage or resistance, and have provisions for remote monitoring and output inhibiting. All control and monitoring connections are on a pluggable terminal block that functions as a connector, providing wiring convenience and permitting easy and rapid connect/disconnect. Outputs are arc/short circuit protected.
-
product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Alarms
IP66 Series
Teledyne Gas & Flame Detection
The IP66 Series of Models A-IP66, V-IP66 and AV1-IP66 consist of an audible sounder (A), a visual beacon (V) or a combination of the two (AV1).All of these options come in impact resistant plastic housings that are rated to IP66 for dust and water ingress protection.The visual warning beacon comes in field interchangeable lens colors of amber, blue, clear, green, red, yellow and magenta.
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25I40-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
CALIBRATOR Multi Function Calibrator
MC140
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
product
CT PT Tester
HTCT-300 / 357
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement of current voltage transformer excitation characteristics, excitation parameters, turns ratio, polarity coil resistance, etc.
-
product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3H-1
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
LOOP/RCD Testers
It can measure trip-out current, trip-out time, on-line voltage, loop resistance and frequency etc. It’s ideal tool for electrical inspection and repair.Comply with IEC/EN 61010-1 1000V CAT III, 600V CAT IV safety standards.Max common mode voltage: 600V AC RMS.
-
product
PXI High Density Precision Resistor Module, 6-Channel, 3.5Ω to 102kΩ
40-298-040
The 40-298-040 is a high density programmable resistor module with 6 channels which can be set between 3.5Ω and 102kΩ with 0.125Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
product
Ground-Fault Detectors for Ungrounded Systems
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.





























