Filter Results By:
Products
Applications
Manufacturers
Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
EcoTestr™ pH 2+ Pocket pH Meter
This new addition to the Oakton EcoTestr product line features updates to make measuring water quality easier and faster. The display is larger with a better viewing angle, has indicators for battery life, readiness, and calibration, and shows both the parameter and temperature readings at the same time. To enhance field use, the cap was redesigned to be leakproof and can be attached to the top of the meter when not being used—no more lost caps! The cap features a fill line, so you know how much sample you need for an accurate reading when using the cap as a sample cup. It is also wider, providing a base to keep the meter upright for hands-free measurements. The keypad now has a fourth key to simplify menu navigation while keeping convenient one-touch calibration. The new housing is compatible with lanyards to prevent losing or dropping, but is still waterproof and floats just in case.
-
product
Bench Ion/pH/mV Meter with ATC prob
CyberScan Ion 510
Low Cost Plus High Performance - offers laboratory-quality readings for a very economical cost :: Multi-Point Push-Button Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA and NIST pH buffer standards for quick calibration with no calibration mistakes
-
product
Carbon Dioxide Meters
A carbon dioxide meter warns optically or acoustically when the carbon dioxide content is critical. Depending on the model, the carbon dioxide meter supports the function of switching relays when an adjusted value is exceeded. This function can help with the automatic conditioning of rooms. The auto calibration function of the carbon dioxide meter makes an easy calibration possible.The carbon dioxide meter supports the function of data storage and further data transfer of measuring results to a computer. Therefore, it is possible to take long-term measurements in order to capture the carbon dioxide content of a specific place for a longer period. Also, you can find a carbon dioxide meter for fixed installations. These can be applied individually or connected to a gas warning system.
-
product
Calibration With Traceability
SKF Condition Monitoring Center
SKF Quality Technology has an established global calibration network for waviness, form and vibration measurements. The QT vibration calibration system complies with the international DANAK and DPLA standards.
-
product
Compact, High-resolution Thermographic Camera
Ceres T 1280 Series
The Ceres T 1280 series is based upon the Dione 1280 OEM thermal imaging core with 1280×1024 pixels and 12 µm pixel pitch and NETD of less than 50 mK. The camera offers superior on-board thermographic performance (accuracy, stability) in the temperature range up to 400 °C.The Ceres T 1280 camera outputs full frame images at 60 Hz via either a CameraLink or at 45 Hz via GigE Vision interface – all GenICam compliant.The compact size and excellent thermographic stability and accuracy, and GenICam compliant interfacing allow for easy integration in demanding industrial thermography applications.The camera offers one standard option of lens and thermal calibration pack.Benefits & Features• Compact and high-resolution• Superior on-board thermographic performance (stability, accuracy)• GenICam compliant• Uncooled operation
-
product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
Software
Measurements International Ltd.
Compatible with All MIL Bridges, Calibration at Fixed-Point Cells, Calibration by Comparison, Automatic Self-Heating Correction, Easy Measurement Setup, Detailed Data Analysis.
-
product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
product
Rack Mount Thermometer Hygrometer
H3531R
Sensor H3531R is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Calibration Devices For Spring Impact Hammer
CX-TF06A
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
product
0-20 mAmp External Sensor
DT139
This MicroLog external sensor can sample any device or transmitter, producing a linear current between 0-20 mAmp. The 0-20 mAmp can be converted to the correct measured units by using Microlab¹s calibration option.
-
product
2-Port 6.5 GHz Analyzer
M5065
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.
-
product
Meter with Electrode
TDS 6+
Automatic or Manual Calibration - for quick, easy calibration; use automatic mode with preset calibration points at most popular values or manually set values in the manual mode for more flexibility
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Torque Tester
TorqueLab® LTT-Series
The torque analyzer is designed for calibrating tools, joint testing, auditing and measuring torque. Torque tools go out of calibration with use. To maintain consistent accuracy, torque tools must be checked periodically for wear or defective parts. A power or hand torque tool is a measuring tool that must be properly calibrated and maintained.
-
product
Machine Capability
NC-Checker
Metrology Software Products Ltd
We fine-tune your machine tools with automated diagnostics and precise calibration. We leave you with our NC-Checker software so you can benchmark the accuracy of your machine to assess its ongoing capability.
-
product
Temperature Calibration
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
product
infra-red turbidity bench meter (NTU) with calibration kit
CyberScan TB 1000
The CyberScan TB1000 series turbidity meters (employing the Nephelometric non-ratio or NTU principle) are designed to meet stringent requirements of today's scientists. TB1000 series meet the performance criteria specified by USEPA method 180.1 for NTU measurement and ISO 7027 (IR version). Ideal for beverage production, drinking water, waste water treatment, petrochemical and electroplating applications.
-
product
Accelerometer Simulator
MTN/8302
The MTN/8302 is a battery-powered unit designed to simulate a constant current type accelerometer. It enables test and calibration of vibration monitoring equipment such as the Monitran MTN/6000 series.
-
product
Calibration Kit
N611
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
product
4-CH Analog Output Module
HSL-AO4-U
The HSL-AO4 offers four analog output channels with a high drive capacity based on the HSL bus. The HSL-AO4 also features 16-bit resolution and offset/gain calibration to minimize the power-on 0-voltage drift to meet precise analog output requirements.
-
product
Radon Professional Monitoring
Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.
-
product
ADAS Tools
This 12.7-inch wireless touchscreen tablet comes replete with all the functionality expected in an advanced diagnostic and service tablet including the ability read and erase codes, view Freeze Frame and view and graph Live Data, perform Active Tests and perform coding and adaptions, plus it includes ADAS calibration and Wheel Alignment software.
-
product
Process Ozone Monitor
Model 465M
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a NEMA 4X wall mount enclosure.
-
product
Waterproof pH Tester
pH54
The Milwaukee Waterproof pH54 Tester is one of our most accurate low cost, rugged and reliable pH testers in the market featuring the ability to easily replace the probe providing for years of carefree use. It's simple 2 point manual calibration is simple-to-use. Ideal for use in aquariums, hydroponics, horticulture, education and many other applications.
-
product
Technology of Global Market Leader
AeroFIS
Aerodata is the only manufacturer of Flight Inspection Systems with an in-house aircraft integration capability and can therefore assume full responsibility for the integrated performance of the aircraft and flight inspection equipment. As a European manufacturer with international recognition, we can provide unique capabilities for the supply of advanced flight calibration equipment with special consideration of compliance with both European (EASA) and US (FAA) regulations, equipment compatibility with neighboring countries, and highest levels of product support.
-
product
Rack Mount Recorders
DTX-9R
DataMAX DTX-9R is a state-of-the-art Windows 2000 based analog instrumentation recorder designed to replace traditional tape based data recorders. Using the latest technology, DataMAX DTX-9R eliminates the time consuming methods of the past with a single precision instrument that will replace a tape recorder, data acquisition system, and monitoring scopes. From calibration to analysis a test can now be run in a fraction of the time, with far greater accuracy than was possible with traditional analog recorders.
-
product
1.533 Μm Frequency-Locked Laser
Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.
-
product
Calibration Test Pumps
High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.
-
product
Load Cell Indicator
9820
Bipolar, 5-digit display featuring 2000Hz high-bandwidth, +/-10V analog output, front-panel shunt calibration and tare, peak and valley monitoring. Sensor connection is via a removable screw-terminal connector.