High Frequency
High Frequency operating at 3–30 MHz.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
High-Frequency Switch
VCH-604
-
High-Frequency Switch VCH-604 is designed for switching high-frequency (1 – 100 MHz) and pulse TTL signals. VCH-604 contains two groups of channels; each group has 25 inputs and 2 outputs. VCH-604 can be controlled from PC via GPIB and RS-232 interfaces or directly from front panel.
-
Product
High-Frequency Signal Amplifier
VCH-605
-
High-frequency signal amplifier VCH-605 is designed to amplify and multiply sinusoidal signals with a frequency of 1-100 MHz.
-
Product
RF/High Frequency Probes
-
Everbeing is proud to distribute GGB Industries line of PicoProbes for customers everyday RF probing needs. The popular model 40A has been serving the needs of many high frequency researchers in the sub-40 GHz range. For more information on their products, visit www.ggb.com. If a product they sell is not shown here, we are still able to acquire for you. Please contact us for more details.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
High Frequency Retrofits and Relocations
-
Our services also include upgrades of existing HF chambers to meet new program requirements, absorber installations, and relocations of chambers from one site to another.
-
Product
High-Frequency Test Coil
-
West Coast Custom Designs, LLC
is most commonly used by the neon industry for detecting leaks in a pumping system; the spark generated by the coil via the solid tip, will enter the tube through the leak and become bright white at the point at which it enters.
-
Product
1231a Very High Frequency Distribution
-
Precise Time and Frequency, Inc.
The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.
-
Product
High-Frequency Amplifiers
-
Tabor’s line of High-Frequency Amplifiers allows for a better, more advanced utilization of the already available digital outputs on some of Tabor’s arbitrary waveform generators.
-
Product
High Frequency Clock Divider Board
-
Alliance Support Partners, Inc.
Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.
-
Product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
-
High Frequency Cartridge for HFP Series Probes
-
Product
High Frequency Coaxial Analytical Probes
-
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
Product
High-Frequency Signal Relays
-
Panasonic Industrial Devices Sales Company of America
Panasonic offers a variety of Signal Relays that can switch high-frequency signals. These products are ideal for applications including radio frequency switching, test and measurement, communication and more.
-
Product
High Frequency (RF) Testing
-
C.C.P. Contact Probes Co., LTD.
CCP designs high frequency testing probes, coaxial probe sockets and pressurized conductive rubber sockets.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Digital Quad-channel High-Frequency Lock-In Amplifier -
eLockIn 205
-
Being the top model eLockIn series, the eLockIn205/2 offers a very fast TCP/IP connection, ultra-fast DAC outputs of the measured signals and all signals supplied at BNC connectors.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
High-Frequency Generator
ZET 7191
-
The ZET 7191 is a high-frequency generator on the CAN bus intended for generating high-frequency signals of any shape. The shape of the generated signals may be of two types: sinusoidal and radio impulse.
-
Product
LXI High Frequency Matrices
-
Pickering's LXI high frequency (HF) matrix modules are suitable for switching frequencies up to 50MHz. They have an impedance of 50 and uses SMB signal connectors or with a larger case size is uses BNC connectors. This HF matrix is designed to provide a simple and scalable bidirectional matrix for radio frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems.
-
Product
High Frequency Noise Simulator
SKS-H04GA
-
Shanghai Sanki Electronic Industries Co., Ltd.
The high-frequency noise simulation generator is an EMC test instrument that reproduces high-frequency noise with a fast rise time when the switch is turned on/off. Since the pulse rise time is less than 1ns and contains wide bandwidth noise, it is very suitable for reproducing malfunctions. The line noise entering the power line and the induced noise entering the communication line can be reproduced, and the performance evaluation of the malfunction and function degradation of electronic products can be performed.
-
Product
General Purpose Pressure Sensors For High Frequency
-
PCB® Series 113B dynamic pressure sensors set the standard for extremely fast, micro-second response with a wide amplitude and frequency range. These characteristics allow them to excel in high-frequency applications, where minimum sensor diameter is required.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76