Cross Correlator
-
Product
Digital Image Correlation (DIC) Measurement System
EduDIC
-
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
Product
Real-time and Direct Correlative Nanoscopy
LabRAM Soleil Nano
-
Fully integrated system based on our OmegaScope scanning probe microscope and LabRAM Soleil Raman microscope. LabRAM Soleil Nano offers unprecedented capabilities for direct co-localized AFM-Raman and photoluminescence measurements. AFM imaging modes (topographic, electrical, mechanical, etc.) and Raman acquisition can be performed either sequentially or simultaneously at the same location of the sample surface. Optical nano-resolution is also achievable with Tip-Enhanced Raman Spectroscopy and Photoluminescence (TERS/ TEPL). LabRAM Soleil Nano is compatible with the environmental chamber for AFM and Raman measurements in controlled atmosphere and at low temperatures.
-
Product
Cross Browser Testing
-
Automate your tests on more than 800 instantly available browser / OS combinations (even beta versions) without the time, expense or hassle of managing infrastructure.
-
Product
Cross Needle Meter. 1.8 - 60/144/440
MFJ-864
-
This new MFJ Cross Needle SWR/Wattmeter covers HF thru VHF 1.8 - 60MHz, 144 MHz and 440 Mhz bands. It features separate HF and VHF / UHF directional couplers, each with its own SO-239 connectors. This lets you connect your HF and VHF/UHF transceivers at the same time.
-
Product
Digital Image Correlation System for Complete 3D Warpage, Thermal Expansion, and Strain Analysis of Materials and Components in the Heating and Cooling Phase
Q-400 TCT
-
The Q-400 TCT system is designed for complete three-dimensional and highly sensitive warpage, thermal expansion measurement and strain analysis of materials and components in the heating and cooling phase. Areas from 50 mm x 70 mm down to 2 mm x 3 mm can be investigated. Measurements can be done from room temperature up to 300°C and down to -40°C. The system is specially suited for thermal expansion measurement of electronic components and is frequently used in the development and testing of complex anisotropic materials, components, and structures in electronic applications.
-
Product
Cross Browser Testing
-
Today’s proliferation of devices and browsers means your user or customer base is highly fragmented and no assumptions can be made about the platforms being used. Through cross browser testing, also known as compatibility testing, Digivante helps you to uncover issues that might block conversion before your users do.
-
Product
Radar Cross Section (RCS) Measurement and Evaluation System
XRC
-
KEYCOM develops various radars for versatile applications based on its knowledge and expertise on millimeter wave and microwave technologies. KEYCOM’s product line of radars includes Radar Test Systems (RTS) to evaluate distance accuracy or output, Radar Alignment Systems (RAS) to help you adjust the alignment of radars, and Radar Cross Section (RCS) measurement systems to measure RCS of such radar targets as aircraft, ships and automobiles.
-
Product
High-Speed Digital Image Correlation System
Q-450
-
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
Product
Crossing Control Bypass Switch
XCBS-DL
-
The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.
-
Product
ABex High Voltage Matrix Module with 12x4 Cross Points
ABex AM-305 HV-Matrix
Matrix Switch Module
The ABex AM-305 is a 12×4 channel high voltage switching matrix module for the Konrad ABex System. The matrix module is designed to switch voltages up to 1000 V with a current of up to 1 A.
-
Product
Crossing Type Panel Meter
ST-70W II
-
Standard Electric Works Co., Ltd
● Sensitivity Full Scale : 100 uA DC● Internal Resistance : 1100 ohm● Accuracy : Class 2.5● Case and Composition : Acrylic resin front and ABS resin case.● Color:Black case, white scale plate or yellow.● Dimension:70(L) × 70(W) × 30(D)mm● Pointer Shape:Knife or Tube-type, color in black or red.
-
Product
Cross Cut Adhesion Tester
1540
-
The Elcometer 1540 Cross Cut Adhesion Tester is a simple instrument for quickly determining the coating adhesion of a large variety of paints up to 50µm (2 mils) thickness.
-
Product
Slides (Ball & Crossed Roller)
-
Del-Tron’s linear ball slides and linear crossed roller slides offer engineers and designers the flexibility to choose the right linear slide technology for their application. Our ball slides and crossed roller slides offer several levels of precision ranging from a straight line accuracy of 0.0005” per inch of travel in our standard precision ball slides to 0.0000040” per inch of travel straight line accuracy in our high precision ball slides and crossed roller slides.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Cross Hatch Adhesion Tester
1542
-
The Elcometer 1542 Cross Hatch Adhesion Tester is ideal for measuring the cross hatch adhesion of coatings up to 250µm (9.8mils) on flat surfaces and test panels.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
-
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
Product
In-Situ Cross- Stack Laser Analyzer
-
LS25 is an in-situ analyzer for non-contact measurement of the concentration of gases. The measuring principle of the LS25 is based on the principle of single line spectroscopy (Tunable diode laser absorption spectroscopy, TDLAS). A single cross-sensitivity-free absorption line of the gas to be measured is selected in the near infrared range. A single-mode diode laser operating at room temperature scans the respective absorption line. By using an opposite receiver, the absorption caused by the sample gas is measured and from this the concentration is calculated. An automatic correction for pressure and temperature changes is possible. In addition, the transmission is displayed respectively output as a signal for preventive maintenance.
-
Product
Cross Platform Data Collection and Analysis Software
PARKvue
-
SPARKvue makes data collection, analysis, and sharing quick and easy on every platform. Compatible with all of PASCO’s wireless and PASPORT sensors, students can quickly set up their lab, or use a built-in Quick Start Lab and begin collecting data immediately. SPARKvue is for all sciences and grade levels. However, if you’re an advanced user looking for more capabilities such as video analysis, advanced statistics and calculations, and greater customization of data displays on a PC or Mac®, then check out our PASCO Capstone™ software.
-
Product
Cross Hole Energizer P/S
CHE
-
Specially designed for small-scale cross-hole surveys, this compact hammer can be used to generate both P and S waves.The hammer can be downloaded using the steel cable and clamped to the requested depth by a pneumatic clamping system manually controlled by a lever from the surface; simply pushing up the steel cable to execute the first shot, the trigger installed on the energizer will start the acquisition for the “P/S”. After that you will have to drop the mass to make the acquisition with inverse polarity.
-
Product
Correlative Microscopy
-
Our modular software platforms enable you to acquire, process and analyze images in multiple dimensions and over various timepoints
-
Product
Collaborative Correlative Microscopy
nanoGPS navYX
-
Correlative microscopy is the combination of multiple modalities performed on the same sample. The results produced emphasize the strengths of each modality while offsetting their individual limitations.nanoGPS navYX™ is an open solution which makes SEM-Raman correlative microscopy seamless regardless of the electron and optical microscopes used. Simply stick the Coordinates Transfer System to the sample!
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
-
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
ABex Matrix Module with 86x4 or 43x8 Cross Points
ABex TM-404 Matrix
Matrix Switch Module
The ABex TM-404 is a 86×4 matrix designed as a universal connection between the test points and the measuring instrument. This can be done locally or via the ABex. The ABex TM-404 can be configured as a matrix with 4 or 8 busses. The internal matrix busses can be switched to the analog bus. The back connector allows to connect the TM-404 to the front of a Konrad PXI-501 ICT card to build a very compact ICT instrument. In addition, this combination can be used as an ABex system controller
-
Product
Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300M
-
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.



























