Correlators
-
Product
ARINC 429 Test And Simulation USB Module
USB-429
-
*4, 8 or 16 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*Sorting according to SDI field*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
PCI-6284 , 32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device
779110-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6284 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Intel Atom® Processor-Based Ultra Compact Embedded Platform
MXE-200 Series
Embedded Platform
ADLINK's new Matrix MXE-200 series Ultra Compact Embedded Platform, based on the Intel Atom® SoC processor E3845/E3826, With superior-class construction meeting a wide variety of specific industrial needs, the MXE-200 series offers the most reliable Ultra Compact Embedded Platform for use in harsh environments, compliant with industrial grade EMI/EMS (EN61000-6-4,61000-6-2), protecting customer assets and reducing TCO. Opposing conventional correlations between size and computing power, the MXE-200 series features large-scale performance in an ultra-compact package.
-
Product
PCIe Gen3 4K Compact, High Speed Camera for Testing
CB120MG-CM-X8G3
-
4K, compact, high speed camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Corrosion Analysis
Resipod
-
Resipod is a fully integrated 4-point Wenner probe, designed to measure the electrical resistivity of concrete in a completely non-destructive test. It is the most accurate instrument available, extremely fast and stable and packaged in a robust, waterproof housing designed to operate in a demanding site environment. The Resipod is the successor of the classic CNS Farnell Resistivity Meter.Surface resistivity measurement provides extremely useful information about the state of a concrete structure. Not only has it been proven to be directly linked to the likelihood of corrosion and the corrosion rate, recent studies have shown that there is a direct correlation between resistivity and chloride diffusion rate and even to determination of early compressive strength. This makes it one of the most versatile NDT methods for concrete.
-
Product
PXI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779123-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Carbon Compound Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
Product
Test Services
-
Our services cover all aspects of test, from test plan generation; to hardware and software development; to validation, correlation, ramp and production. Our experts have deep experience in digital, memory, mixed-signal and RF applications. We also specialize in secured applications that require personalization/root of trust during backend production.
-
Product
Temperature Controlled Microscope Stage
-
Linkham Scientific Instruments
Specialists in temperature controlled microscopy, Linkam Scientific Instruments, announce the launch of their Optical DSC450 which enables simultaneous visualization of thermal processes for improved materials characterisation. The Optical DSC450 enables the user to measure glass transitions and melting behaviour of a wide range of substances whilst accurately controlling temperature from -196 °C to 450 °C. The atmosphere of the stage can also be purged with gas as required by the user. A new feature which will increase the characterisation capabilities of the DSC system is to combine it with imaging capability. The new LINK Digital Imaging module enables additional information to be obtained by correlating optical changes such as colour with temperature. The new TASC analysis tool takes this further. TASC (Thermal Analysis by Surface Characterisation) is a new image analysis capability which enables structural changes in samples to be tracked and quantified optically. It has the unique ability to measure local transition temperatures allowing different points on a sample to be identified. The new DSC system is great tool to use in research and quality control to measure quantitative values for glass transitions, melting peaks and sample purity and, when combined with TASC, even sample homogeneity.
-
Product
NI-9423, 24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module
779009-01
Digital Module
24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9423 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels, can accept up to 30 V discrete logic levels, and has an LED that indicates the status. The NI‑9423 offers isolation between the input and output banks from channel to earth ground. The NI‑9423 is a correlated digital module, so it can perform correlated measurements, triggering, and sychronization when installed in a CompactDAQ chassis.
-
Product
SPSR-2030 (200-3000nm) Super Pure Spectral Radiation Scanning Analyzer
SPSR-2030
-
Hangzhou Everfine Photo-E-Info Co., LTD
SPSR-2030 adopts double-monochromator design, which can realize super-pure&fine full-spectrum scanning ( 200-3000nm), the test parameters including but not limited to spectral power distribution, peak wavelength, dominant wavelength, CCT (correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, and etc.
-
Product
ARINC 429 Test And Simulation PMC Module
PMC-429
PMC Module
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Sorting according to SDI field*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
Dynamic Calibration for ROSS Streak Cameras
DynaCal
-
The DynaCal Optical Calibration Module (OCM) is designed exclusively for the Sydor ROSS Streak Camera to ensure accuracy, both over time and in situ, so you can be confident that the data from your shot is certified to be correlated to the calibration of your camera. The beauty of in situ calibration is that the cost of removing and resetting the camera is avoided—and so is the risk of the replacement of the camera and shifting or disturbing the sensitive nature of streak camera results. Only in situ calibration will reveal the real world effects of EMR, gravity, electronic noise and more when they distort your camera results.
-
Product
Phase Noise Analyzer
NXA-6
-
This new NXA-6 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 6 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
TEM Lamella Preparation And Volume Imaging Under Cryogenic Conditions
ZEISS Correlative Cryo Workflow
-
ZEISS Correlative Cryo Workflow connects widefield, laser scanning, and focused ion beam scanning electron microscopy in a seamless and easy-to-use procedure. The solution provides hardware and software optimized for the needs of correlative cryogenic workflows, from localization of fluorescent macromolecules to high-contrast volume imaging and on-grid lamella thinning for cryo electron tomography.
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
PXI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Hybrid, Multifunction I/O
779639-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Dielectric Loss Tangent and Transmission Attenuation Measurement System
RTS03
-
RTS03 measures relative permittivity (dielectric constant), dielectric loss tangent in the frequency range between 5GHz and 26.5GHz based on a correlation between measurement frequency and transmission attenuation as the microwave passes through the flat plane sample.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196D
Test Fixture
The 16196D surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results – reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement – now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
VIS/NIR Sensor
AF26
-
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
Product
Measuring Wheel
B20-S
-
Simple and light Measuring Wheel B20-s can measure up to 10,000m at 10cm graduation.The counter is indicated in 5 digits and has reset button. When we use Leak Noise Correlator LC-2500, we need to input the between pick-up sensors.
-
Product
Geiger Counters
-
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
Product
ENA-X Vector Network Analyzer
E5081A
Vector Network Analyzer
Our spectral correlation technique directly analyzes the modulated input and output signals in the frequency domain on the network analyzer. Current solutions on the market require a network and spectrum analyzer to characterize components fully. With the new ENA-X, you can ensure test accuracy and repeatability with a single test setup using full vector correction at the DUT plane. Avoid manually reconfiguring setups or automating complex switch-based systems — verify device performance faster and with less error potential with the ENA-X network analyzer.
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
Motor Test for Stepping Motors
-
*Stable measurement: Since it uses Prony braking, this model provides stable measurement unaffected by moments of inertia and no coupling loss. In addition, the resulting measurements allow data correlation via the traditional double-balance method.*Precision measurement method: This model’s judgment of synchronization loss achieves high stability using algorithms developed by Sugawara Laboratories. Measurement mode can be chosen based on step angle. For pull-in torque, startup can be measured consistently from the holding state. Allows measurement at 1-Hz resolution.*Broad measurement range: This model offers a range of seven available measurement heads, from 0.5 N to 50 N, allowing use for high-precision measurements. Through selection and use of pulleys, this model can also be used to measure small motors of 0.5 mN·m or less or 500 mN·m motors. Pulley diameters and other settings are easily configured using a personal computer running Windows®. Note: Any of the seven available heads may be attached to a single measurement component.*High-visibility measurement data: Motor characteristics are easily ascertained on automatically plotted performance graphs. Measurement data can be overlaid up to four times. In addition, the cursor can be used to read accurate values from measurement points. Hard copies of data displayed on-screen can be printed from a personal computer.*Can be controlled using standard personal computers: Allows control of measurement operations and display and storage of data from a standard personal computer running Windows®. Data is stored in CSV-format files for compatibility with other software applications.
-
Product
NI-9411, ±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module
779005-01
Digital Module
±5 V to 24 V, 6 Differential/Single-Ended Channels, 500 ns C Series Digital Module - The NI‑9411 works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and devices. The NI‑9411 is a correlated digital module, so it can perform correlated measurements, triggering, and synchronization when installed in a CompactDAQ chassis.