Counting
-
Product
Online UV Analyzers
-
Accurately monitor performance of UV filtration systems with online UV analyzers. Our online UV analyzers use UV254 technology to provide accurate water quality tests. Help ensure safe municipal wastewater with trusted wastewater UV analyzers you can count on.
-
Product
Handheld Digital Multimeter, Compact, 3999 Count, True RMS, Auto Range, 4.75 Digits
72-9380A
-
A premium, compact hand-held digital multimeter that boasts a 39999 count display and an optically isolated USB interface.
-
Product
Bench Digital Multimeters
-
High accuracy Bench HMM with Interface4000 counts LCD display with 42-segment bargraph, backlit and unity annunciators.AC/DC powered allows carrying to the site built in storage compartment for accessories True RMS AC current/voltage measurement
-
Product
OEM Count Input0 to 255n
TGPR-1200
-
A count input data logger that is supplied uncased so that it can be built into custom applications. Common applications include flow rate and quantity monitoring.You can find more information on Tinytag count data loggers in this application note:
-
Product
PXI Very High Density Versatile 2 Amp Multiplexer
40-612A-002
-
The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128
-
Product
Multi-Channel Analyzer
-
The MCA1K is a compact multi channel analyzer (MCA) for processing gaussian inputsIt is capable of sorting input pulses from shaping amplifiers into 512 discrete bins.Each Bin can record up to 16M counts before an overflow event occurs.
-
Product
PXI-2546, 2.7 GHz, 50 Ω, Dual 4x1 PXI RF Multiplexer Switch Module
778572-46
-
2.7 GHz, 50 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2546 is an RF signal multiplexer switch module. The multibank architecture of the PXI‑2546 makes it ideal for test systems that require parallel operations such as RF stimulus-response testing. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
PXI-2799, 40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module
782359-01
-
40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2799 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2799 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
24 Channel Isolated Counter / Totalizer & 16 Channel Pulse Simulator
DP-cPCI-5004
-
DP-cPCI-5004, Isolated Pulse Simulator / Counter / Totalizer module is an integrated module for pulse output, pulse measurement and event counting. The module has 16 isolated channels of pulse output at desired frequency. The 16 channels are divided into three groups . The first two groups have four differential and one single ended channels each.
-
Product
PXI/PXIe Very High Density Multiplexer, 24-Channel, 8-Pole
42-675B-002-24/8
-
The 40-675B-002-24/8 (PXI) and the 42-675B-002-24/8 (PXIe) are 24-channel, 8-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
Bench Multimeter 21000 Counts
VA81/VA80
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Key Features: 21,000/51,000 count display Large VFD dual-display with high brightness True RMS AC voltage and current meas.
-
Product
PXI/PXIe Very High Density Multiplexer, 198-Channel, 1-Pole
40-675B-002-198/1
-
The 40-675B-002-198/1 (PXI) and the 42-675B-002-198/1 (PXIe) are 198-channel, 1-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
PXI 3A Power MUX BRIC, 10-Channel, 24-Pole
40-571-105
-
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
Electronic Dosimeters & Readers
-
Readers operate using software packages installed on computer (PC) and communicate with DMC 3000 dosimeter and DMC 2000 and SOR families in hands-free data exchange mode. the LDM 320 reader is used as an interface to activate a dosimeter (to switch into counting mode) or to deactivate it (to switch into pause mode). When used with the included* DMCUser software, it functions as an interface to read and write the internal data of the DMC 3000, SOR and DMC 2000 dosimeters.
-
Product
Charge Sensitive Preamplifier-Discriminator
A101
-
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
Product
PCI High Density Potentiometer Card 4-Channel, 16-Bit, 0 To 65k Ohm
50-296A-121-4/16
-
The 50-296A series are Programmable Potentiometer versions of the 50-295A Programmable Resistor cards with up to 9-channels of 8-bit resolution resistor chains in a single PCI slot. The flexible architecture allows the card to also be supplied as 12-bit, 16-bit or 24-bit resolution versions for applications requiring finer resolution, greater resistance range or higher channel count. The card is ideal for simulating the sensors for control and management systems under test, allowing the user to verify system response in design verification or manufacturing test applications.
-
Product
PXI 3A Power MUX BRIC, 24-Channel, 12-Pole
40-571-306
-
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXIe-2524 , 128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module
780587-24
-
128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module —The PXIe‑2524 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 1‑wire multiplexer configurations: 16 bank 8x1, octal 16x1, quad 32x1, dual 64x1, and 128x1. The PXIe‑2524 also features onboard relay counting for relay monitoring.
-
Product
PCI High Density Resistor Card 3-Channel, 24-Bit, 0 To 16M Ohm
50-295A-021-3/24
-
The 50-295A is a Programmable Resistor card with up to 18-channels of 8-bit resolution resistor chains in a single PCI slot. The flexible architecture allows the card to also be supplied as 12-bit, 16-bit or 24-bit resolution versions for applications requiring finer resolution, greater resistance range or higher channel count. The card is ideal for simulating the sensors for control and management systems under test, allowing the user to verify system response in design verification or manufacturing test applications.
-
Product
Compact Manual Ranging 600V Multimeter
DL9204
-
Compact manual ranging digital multimeter with 2000 count LCD display. Full protection on all ranges, safety category to CAT 111 600 V. Functions include battery and diode test.
-
Product
PXIe Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Single Channel Mode
42-611B-002
-
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available.They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC. They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
PXI BRIC8 FIBO Matrix Dual 120x4 3pin brkout
40-592A-106
-
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
Product
Leaking Current Meter
7610B
-
Peaceful Thriving Enterprise Co Ltd
This is a stable, low power consumption, and high accuracy 3 1/2 digits (2000 counts) leaking current tester for automobile. Leaking current for automobile is generally as small as milliamps, which is hard to measure by clamp meter. By plug this meter with the fuse box, user is able to measure leaking current as small as 1 mA.
-
Product
PXI Potentiometer Module 4x12 Bit, 0 Ohm to 4K Ohm
40-296-121-4/12
-
The 40-295 is a Programmable Resistor module with up to 18 channels of 8-bit resolution resistor chains in a single 3U PXI module. The flexible architecture allows these modules to also be supplied as 12, 16 or 24-bit resolution versions for applications requiring finer resolution, greater resistance range or higher channel count.
-
Product
LXI WTB Adaptor, Thru line
60-982-001
-
The 60-982 provides a effective method of adapting trigger signals from bench instruments to the LXI Wired Trigger Bus signalling standard. The 60-982 converts M-LVDS signals on the WTB to Low Voltage TTL signals and converts Low Voltage TTL signals to M-LVDS. All 8 channels of the LXI WTB are supported in a single adaptor. Each channel of the WTB can be configured either manually or through a digital I/O to be Disabled, Driven or in Wired OR mode. The interface is fully compatible with the LXI WTB standard and counts as one node on the bus.
-
Product
PoE Ethernet I/O Module w/ 3-axis Encoder/Counter Inputs
PET-7083
-
A great device, that works well for building automation, factory, and machine automation, remote maintenance, testing, and diagnosis, the PET-7083 is a 3-axis high speed encoder/counter module. Its each axis can be individually configured for Quadrant, Pulse/Direction or CW/CCW counting modes. The maximum input rate for Quadrant counting mode is 1 MHz, and for Pulse/Direction, CW/CCW counting modes is 4 MHz. The encoder/counter module is equipped a FRAM to retain the counter value after it is powered off. FRAM is a nonvolatile memory that can hold written data even after it is powered off. The data retention can be 10 years. And the feature can be configured as enabled or disabled.
-
Product
Mechanical Counter
SP101/102 Series
-
The SP-101/102 Series is a heavy duty totalizer. It has a double sided shaft for stability. Available in Revolution or Rotary type movements. Input shaft direction is choice between top going or top coming. Count speed range from 300 ~ 3000 rpm. It is a available in 4 or 5 digits with a large digit size of 6.0 x 4.0mm. Resetting of count value is done easily with the front push button reset.
-
Product
USB-6361, 16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
782255-01
-
16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6361 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6361 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
-
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PCI High Density Resistor Card 18-Channel, 8 Bit, 0 To 255 Ohm
50-295A-121-18/8
-
The 50-295A is a Programmable Resistor card with up to 18-channels of 8-bit resolution resistor chains in a single PCI slot. The flexible architecture allows the card to also be supplied as 12-bit, 16-bit or 24-bit resolution versions for applications requiring finer resolution, greater resistance range or higher channel count. The card is ideal for simulating the sensors for control and management systems under test, allowing the user to verify system response in design verification or manufacturing test applications.




























