Transformer Turns Ratio
measures a transformer's number of primary winding turns to it's secondary turns.
See Also: Winding, Transformer Turns Ratio Testers
-
product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
product
Multiplexer For Transformer Testing
MUX-R
Raytech Multiplexer MUX R is designed to drastically reduce cabling time and increase test performance. It is made to be used with Raytech Winding Resistance and Turns Ratio Meters. Any MUX R configuration can be easily controlled by a Winding Resistance Meter touch panel or by remote.
-
product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
product
Current Transformer
ST-3RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 20~300
-
product
Separating Transformers
Is a transformer in which the primary and secondary windings are galvanically/electri- cally separated with basic insulation. Isolating transformer: A separating transformer with a protective partition between the primary and secondary windings.
-
product
DELTA™ III 3-zone Flow Ratio Controller
The DELTA™ III Flow Ratio Controller divides and controls mixed process gas flows to three chambers or zones within a process chamber at proportions specified by the user to optimize process uniformity and repeatability. Available with EtherCAT® or DeviceNet™ communications, this device provides the latest in gas flow ratio measurement and control technology.
-
product
Current Transformer
ST-30CT
Standard Electric Works Co., Ltd
● 30/5A - 150/5A● 2-3V A● Class 1● Insulation 600V
-
product
Series Precision Fixed-Ratio Current Transformers
PMT25100
Power Measurement Technologies Inc.
Precision two-stage toroidal current transformers find application as the reference in determining the accuracy of instrumentation current transformers.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
Current Transformers
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
product
Automatic Transformer Test System
TH2829CX
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 20 ■ Frequency: 20Hz-1MHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
product
Instrumentation Transformers
RR manufactures Transformer for Oil Test Set / Oil BDV Set. These are available in→ 25-0-25 KV→ 30-0-30 KV→ 40-0-40 KV→ 50-0-50 KV→ 60-0-60KV→ Higher ranges availableThese transformers are available in various models to suit various needs and budgets. We Specialize in manufacturing LOW WEIGHT TRANSFORMERS for AUTOMATIC OIL TEST SET MICROPROCESORS.
-
product
Transformer DC Winding Resistance Tester
HTZZ-50A / 246
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm
OSA201C
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.
-
product
Power Transformer Testing
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime.
-
product
Instrument Transformer Testing
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
product
10-channel turn-to-turn Insulation Scanner
TH28831
Changzhou Tonghui Electronic Co., Ltd.
Work together with TH2883, expand single channel to 10-channel
-
product
Transformer Oil Gas Analysis
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
product
Uniload Voltage Transformer Test Set
2J6
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.
-
product
Current Transformers Test Set
Supreme Instrument Laboratories
The basic unit is sensitive magnetic comparator and also it incorporates electronic null detector to facilitate the balance. The reference Current 5A. or IA. obtained from Standard Current Transformer and in comparison to that the vector length and phase displacement is measured. The ratio error in percentage and phase displacement in minutes are directly compared and indicated on dials.
-
product
Compact Prewired Current Transformers
Contrel Elettronica s.r.l. Company
Current transformers are essential components designed for use with the broad range of energy monitoring products.
-
product
Isolation Transformers
Osborne’s Isolation Transformers are used to step-up, step-down and isolate voltages in single phase circuits. Isolation may be used to provide output circuit immunity from voltage spikes and noise (both common-mode and transverse-mode) present on the input system. The isolation can allow separate grounds on both the input and output sides of the transformer. Osborne also designs with a range of electrostatic shielding to provide several levels of noise immunity.
-
product
Automatic Winding Turns Tester
This tester has the advantage of high accuracy and efficiency, limited influence due to the form and size of the coil to be analyzed, and fast & easy operation thanks to the precision sensor and microprocessor that adopt the patent know-how developed by the manufacture. This tester, when in operation, does not need any further adjustment and calibration. Just connecting the clip leads to each terminal lug of the coil winding, then the tester instantly shows the exact number of the winding turns on the digital display. Unlike other similar devices, input the data of standard coil to test against is unnecessary. In this way, this tester greatly upgrades the inspection and analyzing efficiency.
-
product
Transformer DC Winding Resistance Tester
HTZZ-10A / 235
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Multiple Gas Transformer DGA
MINITRANS
Based on the same core technology as the highly successful TRANSFIX the MINITRANS is a lower cost alternative, monitoring three key gases: Hydrogen, Acetylene and Carbon Monoxide (in ppm) plus moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect a wide range of developing faults including arcing.
-
product
Transformer Test Equipment
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
product
Burn Down Transformer
ATG 2
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
product
Relaying Current Transformer Analyser
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).





























