-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1L-10
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
In-Circuit Tester Integration
The benefits of boundary-scan are noticed in all phases of a product life cycle. By coupling the power of Corelis boundary-scan tools with an In-Circuit Tester (ICT), a complete, integrated solution is available that offers the best advantages of both technologies.Boundary-scan operates as the perfect companion to ICT. Boundary-scan is capable of testing areas of printed circuit board assemblies that are difficult to access due to physical space constraints and loss of physical access, which is often due to fine pitch components such as Ball Grid Array (BGA) devices. Conversely, the ICT is able to check the non-boundary-scan compatible portion of the unit under test (UUT) such as analog.
-
product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74T135-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Consumer Battery Test Equipments
Guangdong Bell Experiment Equipment Co.,Ltd
Many electronic products are around our daily life nowadays, smart phones, tablet, wearable devices, laptop, home robot, etc. The rechargeable battery, mainly Lithium-ion battery are widely adopted in such products. There is greater demand of battery safety testing from both of battery and product manufacturers. They should make sure the battery is qualified before delivering to customers.
-
product
Alternate 2.65 (75.00) - 6.50 (184.00) Bead Probe
BTP-25HF-6.5
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
microDXP
The microDXP is a complete, low power compact digital spectroscopy card design for a wide range of handheld, benchtop and other embedded applications, lowering cost and speeding time-to-market. Its small size allows for very compact assemblies and its low power consumption assures thermal stability and extended battery life.
-
product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72I-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
DL Linear Actuators
Del-Tron's DL series linear lead screw actuators and ball screw actuators offer the benefits of a space-saving design, fast and simple assembly, long life, and a competitive price. The rigid enclosed aluminum box structure provides a compact envelope that incorporates the linear bearing and drive mechanism. Integrating all components into a single unit that includes the motor adaptor saves assembly time and eliminates the need to source additional parts. DL series linear actuators are offered in travel lengths up to 410 millimeters.
-
product
EMCCD Cameras
iXon Life
With the iXon EMCCD cameras, Andor have delivered a dedicated, truly high-end, yet accessible ultrasensitive scientific camera platform, designed specifically to drive the absolute best from EMCCD technology across all critical performance specs and parameters. Andor’s new iXon Life EMCCD platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. Perfect for single molecule detection and live cell microscopy with minimized phototoxicity or photobleaching, but at a price more normally associated with back-illuminated sCMOS cameras.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1T-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Linear Gauge Sensors
GS Series
All the GS series Digital Linear Gauges are upgraded. The GS-1700/1800 series is a compact and cost effective basic type. The GS-6700/6800 series is a vibration resistant type which provides better performance of vibration resistance 1.5 times in strength compared to the basic type. The GS-4700/4800 pursuits heavy-duty performance required in production site. Long stroke type the GS-5050/5100 series has wide measurement range (stroke) at 50 mm or 100 mm. Using ball bearing mechanisms in these all models greatly increases bearing life.
-
product
Digital (1kV up) H.V. Insulation Tester
4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L18-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Dual 16x2 1-Pole High-Density PXI Matrix Module
40-520-501
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1T-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Trace Oxygen Analyzers
Alpha Omega Instruments trace oxygen analyzers and transmitters incorporate an advanced electrochemical sensor that provides exceptional life, accuracy, and stability. Alpha Omega Instruments electrochemical sensors provide as much as three times the life of conventional “fuel cell” type sensors. And, if you are looking to measure from parts per billion to 100%, Alpha Omega Instruments offers a high-performance zirconium oxide oxygen sensor.
-
product
PXI Dual 16x8 Matrix, 2 Pole Switching
40-532-022
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
product
PC104 Single Board Computers
ADLINK products include the most rugged offerings in the industry, Single Board Computers (SBC) in popular compact form factors for embedded applications, and rugged systems with field-proven reliability, durability, and performance. PC/104 family products provide unmatched fanless operation over temperature extremes, resistance to shock and vibration, conformal coating, embedded BIOS, and a long product life reputation. The products continue to distinguish itself as an Extreme Rugged product for a multitude of applications. Mini-ITX embedded boards support the latest processors to deliver a high performance and space-saving platform for a wide array of embedded computing applications.
-
product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Inverted Light Microscopes
Inverted microscopes from Leica Microsystems are designed to meet the rigorous demands of life science as well as material science and industrial applications.
-
product
Endurance Tester
Premier's Endurance Tester, also known as on-off tester and life tester, is used to perform the life test of the unit. The Endurance Tester, switches on the unit for a set time and then turns it off for a set time. This entire cycle is repeated multiple times, to simulate the behavior of the unit under extended use
-
product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4J-2
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
PXI Programmable Step Attenuator Module, DC to 50 GHz
M9168E
The M9168E is a programmable step attenuator module based on PXI hybrid platform. The M9168E operates from DC to 50 GHz with a guaranteed 0.03 dB insertion loss repeatability for each section throughout the 5 million cycles operating life. Superior attenuation accuracy across a wide operating temperature range ensures precise measurements.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I8-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Low PIM Coaxial Switch, DC to 20 GHz, Matrix
87606Q
Low passive intermodulation (PIM) is crucial for applications where two or more transmitted signals share a common antenna or whenever the transmitter signal is too high or the receiver is sensitive to high intermodulation. The Keysight 87606Q is a low PIM matrix coaxial switch, operating from DC to 20 GHz, which can help to keep the system PIM level low. A guaranteed 0.03 dB insertion loss repeatability and 3 million cycles of operating life ensures signal integrity, improves testing efficiency, and ultimately maximizes test throughput.
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I8-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1I-2-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Probe Systems
Mini-PS4L
The mini-PS4L series of probe systems are built using a similar concept as our patented Probe System for Life (PS4L) Architecture. The base system is built on a 300 mm x 300 mm metric breadboard and that allows the user to configure the system to meet the application and budget.
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Brahmos Checkout
Data Patterns designed and built the BrahMos Missile Checkout Equipment based on the requirements and support of DRDO and BrahMos. This unit validates the complete performance of the Missile through interfacing with it's umbilical and maintenance connections. The shelter mounted checkout equipment is utilized to test the articles on the field during it's life cycle, thus ensuring readiness for launch on demand.





























