Electrodes
-
Product
Handheld Water Quality Meters
LAQUA WQ-320-K
-
- Dual channel- Large colour graphic LCD screen (70 x 52 mm) with backlight - Built-in foldable meter stand- IP67 waterproof and dustproof- Battery and USB powered- Eco-friendly, shock-proof, scratch-resistant, and non-slip- Built-in sensor holders- Efficient sensor locking mechanism- Sensor's LED light as reading stability indicator- No sensor adapter needed for attaching multiple sensors together- Compatible with conventional electrodes having BNC and phono connectors and long cables- Sensor status indicator- Temperature sensor indicator- °C & °F temperature units- Sample ID setting- Detailed calibration data- Auto stable, Auto hold, and Real time measurement modes- Customizable meter kit - up to 15 meter-sensor kit combinations- Hands-free testing- Ergonomic design- Multi-language options- Versatile channel and adaptive display- Up to 2 simultaneous calibrations and measurements- Automatic sensor recognition function- Data transfer via USB or wireless communication- Printer communication- 3 years meter warranty
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission)
HP-480
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Meter With pH Electrode, ATC Probe
pH 2700
-
Oversize screen with large fonts yet compact – the new Eutech pH 2700 offers an easy to read screen that says more! View pH or ORP readings, with temperature, electrode status, calibration points, date and time all at once!
-
Product
MyoWare 2.0 Muscle Sensor
-
Using our muscles to control things is the way that most of us are accustomed to doing it. We push buttons, pull levers, move joysticks... but what if we could take the buttons, levers and joysticks out of the equation and control it with our muscles? The MyoWare® 2.0 Muscle Sensor is an Arduino-compatible, all-in-one electromyography (EMG) sensor from Advancer Technologies that allows you to do just that! The MyoWare 2.0 Muscle Sensor has been redesigned from the ground up with a new easy-to-use, compact design and upgraded with the latest and greatest chipset improving sensor performance and reliability. The innovative snap connector system eliminates the need to solder connections for the MyoWare 2.0 ecosystem. It's that easy: stick on a few electrodes (not included), read the output voltage and flex some muscles!
-
Product
Static Decay Timer
PDT-740B
-
Designed to measure the time required for a 1,000 volt charge to dissipate to less than 100, 50 or 10 volts in tenths of a second.Used to evaluate the static decay capabilities of materials, personnel, equipment and other products.Compatible with most portable CPM's and field meters having an analog output of ± 2 (10,000 volts equals 1 volt).Used in conjunction with the PFM-711A Field Meter.Can be used with the PGB-745 Decay Electrodes or PRF-911 Concentric Ring
-
Product
Solid State Relay
5200
-
The B/W 5200 Series solid state relays are offered in two basic types for use in a wide range of low and high sensitivity applications.Both 5200 solid state relays are designed to operate on either 115 or 230 volts AC at 50/60 hertz.Both models incorporate a low voltage sensing circuit.Furhtermore, both solid state relays are capable of performing control functions directly from electrodes suspended in a well or tank, the B/W Unifloat level sensing system, or various pilot devices such as pressure, flow and limit switches, thermostats and push buttons.
-
Product
Model DG-9 (Universal Voltage)
DA8-G9-UNIV
-
Designed for semi-solids; powdered, granular or textile materials; and pliable sheets in rolls or stacks. Optional needle electrodes and sensitivity modules which allow for a wide range of moisture measurements. Rechargeable NiMH batteries save hassle and money of battery replacement.
-
Product
Isolation Tester UIP
-
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.
-
Product
Bridge Decking Testing Equipment
-
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
Product
Earth Resistance Testers
-
Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
-
Product
Meter With 4-Cell Conductivity/ATC Probe
CON 2700
-
Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.
-
Product
Rectal Probe For Mice (Isolated)
RET-3 ISO
-
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - 3/4'' long, .028'' diameter. Tip diameter .065'', 5 foot lead length. Time constant 0.5 seconds.
-
Product
Electrocardiogram Logger Sensor
NUL-218
-
Identical in its use to a regular medical ECG (electrocardiogram), this is a rather simple three lead based logger sensor. It presents a heartbeat graph that allows a thorough examination of the heart's electrical activity from three different angles. Unlike most ECG devices, this unit operates with non-disposable electrodes.
-
Product
Rotating Ring Disk Electrode
RRDE-3A
-
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
Product
Biosensor isoPod
EP352
-
A compact signal conditioner for monitoring low current, two-electrode (anode and cathode) amperometric sensors.Electrical isolation ensures that readings are not influenced by nearby current sources such as conductivity, or voltammetric electrodes.
-
Product
BOMBARDING A.C. MILLIAMPERES METER
-
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
Product
Flat Carbon Sensor Conductivity meter
HE-960LF / FS-09F-1/2
-
It is effective to keep the dilution of Slurry constant. Maintaining an appropriate conductivity value contributes to process stability in the wafer polishing process. Even highly viscous sample liquids such as CMP Slurry can be measured without problems because they use a sensor structure that reduces the risk of the sample liquid sticking to the electrodes. In addition, the sensor is made of a wetted material with excellent chemical resistance, which meets the cleanliness requirements of semiconductor processes. In addition to the above, it can also be used for introduction at the semiconductor process development stage and conductivity control of special chemicals.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
AA Neon Tube Tester
-
West Coast Custom Designs, LLC
When the antenna is touched to the tubing wall or electrode wires, the tester will cause the viable tubing to illuminate in a pulsating manor. This pulsing feature is fantastic for testing neon in bright sunlight as it is easier to see the light when flashing.
-
Product
Remote Monitoring System
SuperSting
-
The AGI SuperSting Remote Monitoring System (SSRMS) is designed for unattended monitoring applications on landfills, well sites, dams and other locations where changes of resistivity conditions over time need to be recorded and analyzed. The electrodes can be installed at the surface or in bore holes.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
pH 2700 Benchtop Meters
-
Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring.
-
Product
pHTestr® 50 Waterproof Pocket pH Tester,
Premium 50 Series
-
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
Product
Ring Disk Electrode
-
This ring-disk type electrode developed by NTT Advanced Technology Corporation is a form of printed electrodes. Users can choose them from Carbon, Gold and Platinum applied versions. Available as a working electrode of radial flow cells, achieves complete reduction/oxidation on the center disk at ultra-low flow rate because of its fine coulometric electrolysis efficiency. This also enables to analyze subsequent reaction as well as identification and quantitation of the sample at the same time.
-
Product
pH Electrode Holder
PF12
-
Extension of optek sensor bodies for inline pH measurement in industrial installations of various applications. Commonly available Ø 12mm & 120 mm length pH probes can be used and are positioned at an optimum angle into the process stream.
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
Telurometer
AMRU-200
-
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
Product
Galvanic DO Electrode for DO and BOD Measurements in Laboratories
9521-10D
-
- Ideal for laboratory use- Integrated with built-in temperature sensor- Comes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer - Use magnetic stir plate during measurement- Waterproof
-
Product
Salinity Testers
-
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.