product
Turns Ratio Meter 3 Phase
TR-MARK III 250V
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.
-
product
Testing of Voltage Measuring Transformers
In this category you will find components for high-voltage testing as well as for testing electronic or conventional voltage measuring transformers.
-
product
Transformer Capacity Load No-load Tester
HTRS-V / 261
Wuhan Huatian Electric Power Automation Co., Ltd.
High precision instrument used in transformer capacity, no-load, load and other characteristic parameters measurement.
-
product
Ground-Fault Location Products for Ungrounded Systems
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
43-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal.
-
product
Resistive AC Load Bank
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase
SL1202A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
DC Power Supply
PW-3033R
*Toroidal Transformer*Low EMI & High EMS*Very Low Ripple & Noise*30V/3A+30V/3A+5V/3A Triple output.*Tracking operation.*<0.3m Vrms Ripple & Noise(C.V.)*<2m Arms Ripple & Noise(C.C.)*4 Display.
-
product
Autotransformer
T-1007
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
product
Milliohm Meter
Utility area: measurement of secondary transformer winding ;measurement of division switch for sufficient low-ohm value
-
product
Current Transformer
ST-30RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 1600~4000
-
product
Power Quality Testing
Weshine Electric Manufacturing Co., Ltd
Transformer K Factor, Power factors(PF)and displacement factors, Short-term voltage flicker, .Three phase unbalance (Current and Voltage), Waveform real-time display(4 channels voltage /4 channels current) True RMS values of voltages and currents
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
USB-485/4, 4-Port, USB, RS485/RS422 Serial Interface Device
778476-54
The USB‑485/4 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/4 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
product
Current Transformer Analyzer
CT Analyzer
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
product
Dielectric Insulation Analyzer
DIRANA
DIRANA uses dielectric frequency response (DFR) analysis in order to determine the condition of high-voltage insulation systems such as those in power transformers, bushings, cables and generators.
-
product
Compact Box PCs And Digital Signage Players
ADLINK industrial box PCs and digital signage players are designed to meet the diverse needs of industries such as retail, transportation, and manufacturing. These compact edge computing solutions ensure reliable performance for real-time data processing and seamless vivid content delivery. Featuring industrial-grade durability, flexible I/O configurations, and scalable options, the EMP Series helps businesses optimize operations, enhance customer engagement, and drive digital transformation in demanding environments.
-
product
Transformer Turns Ratio Meter
TTRM 101
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Coaxial Waveguide Adapter, 2.4 mm (m), 26.5 to 50 GHz
R281B
The Keysight R281B adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
Transformer Performance Tester
JYW6100
JYW6100 Transformer No-loads and On-loads tester power factor tester is suitable for loss testing of low power factory transformer such as amorphous alloy transformer, with high precision and data loc
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
12 kV Insulation Fluid Test Cell
CP TC12
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
product
Coaxial Waveguide Adapter, 2.4 mm (m), 33 to 50 GHz
Q281B
The Keysight Q281B is a 2.4 mm male to WR-22 waveguide adapter that operates in the 33 to 50 GHz frequency range. These adapters transform waveguide transmission lines into 50 ohm coaxial lines. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
L.V.D.T Products
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
product
FTIR – Fourier Transform Infrared
FTIR stands for Fourier Transform Infrared spectroscopy. It is a powerful gas measurement technology for simultaneous measurements of multiple gases. The ability to detect and measure almost any gas, combined with the robustness and reliability of the technology, makes FTIR ideal for a wide variety of applications.
-
product
Instrument Transformer Calibrators
MRL 22
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Megohmmeter Insulation Tester
AMIC-30
The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.
-
product
Inverters
Analytic Systems has been producing Pure Sinewave Inverters since 1994. Originally designed for running navigation computers on commercial and fishing vessels, the line has evolved into a range of models with power outputs from 300 to 3600 watts featuring Digital Signal Processor control. High power MosFet technology creates a low voltage Sinewave that is fed into a compact toroidal step-up transformer to produce a very clean low EMI AC output. Northrup Grumman evaluated inverters from all major manufacturers and chose the IPSi series by Analytic Systems for their Army portable command centers for precisely this reason.
-
product
Winding Resistance Meter
TRM 104
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.