product
Flow Monitors
B3000 Series
The B3000 Series flow monitor from Blancett provides a flexible, durable, easy-to-use platform for flow metering applications. The B3000 monitor makes it easy to track flow, with a crisp dot-matrix display capable of simultaneous display of flow rate and flow total. With a wide variety of enclosure options for both liquid and gas applications, from intrinsically safe and explosion-proof (flameproof) ratings, to an innovative solar-powered model, there''''s a B3000 monitor to suit your needs. Available instrinsically safe models are housed in a UV-resistant, NEMA 4X-rated enclosure available in direct, panel, pipe, DIN-rail and swivel mounts.
-
product
Face Masks Particulate Filtration Efficiency PFE Tester
GLE-20
GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. According to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow.
-
product
Water Manometers
The AC6 Manometers are available in standard or high pressure versions. The AC6-SP Manometer can be used to measure differential pressure in the range 0.5-200 KPa and the AC6-HP Manometer operates in the differential pressure range 2-600 KPa. These electronic water system commissioning test sets have in built valve and orifice plate Kv values which enables the instrument to calculate and display flow rates during commissioning.
-
product
On-board Emissions Measurement System for SPN10
OBS-ONE SPN10 Unit
The OBS-ONE SPN10 unit is an on-board emissions measurement system for analyzing the SPN10 (solid particle number emissions >10 nm) under real-world driving conditions. It meets the latest trends in particle number regulations in the future.The SPN10 unit combines with the GAS unit and the NH3/N2O unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
product
Stimulation/Fracturing
Atmospheric Rotational, Pressurized Rotational, In-Line Viscometers, Friction Flow Loop, and Formation Response.
-
product
High-Precision Fuel Flow Measurement System
It enables to keep the temperature fluctuation of the circulation flow path in the system within ±0.2 °C (for 1 minute), which achieves stable fuel flow rate measurement.
-
product
Power Quality Meter
Qualstik
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
product
Trace-Level Dilution Calibrator
Model T700U
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
product
Electronic Inspection Systems
Intego's knowhow even makes it possible to identify challenging defects that may be located under the surface. One system is the inspection of chips by means of lock-in thermography, which visually represents the IR radiation intensity signal of electronics. Special lasers and flash lamps generate a very short heat impulse (10 ms) on the chip, which generates a measurable heat flow. In most cases, a resolution of < 1 μm can be achieved.
-
product
Cement Testing Equipment
High quality cement is necessary to produce concrete and mortar that meets relevant construction industry specifications. ELE international designs and manufactures a wide range of sample preparation and cement testing equipment which complies with global standards for the assessment of fineness, consistency, setting time, workability, flow, strength, soundness, heat of hydration and chemical composition.
-
product
NIR & UV-VIS Process and Lab Analyzers
The optical or spectrum analyzer is the brain which transforms the signal collected by the sample interface into actionable information. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV-Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal light transmission for long-term reliable measurements. More information is available about specific analyzers on each product page or on the process analyzer product overview.
-
product
PCIe Gen3 4K at 500 Fps High Speed Compact Camera for Testing
CB160MG-LX-X8G3
4K at 500 Fps High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
Vane Anemometer
AM-4836V
Parameters measured: Wind speed, Flow, Beaufort Scale, Wave, Temp., wind directionRange:Wind speed: 0.4-30.0m/s1.4-108.0km/h80-5910ft/min0.8-59.3 knotsFlow: 0.004-9999 m³/min0.013-9999 ft³/minB. Scale: 0-12 forceWave: 0-14mDirection indicator: 16 ways (the resolution is 22.5º)Temp. : 0-60℃ / 32-140℉Accuracy: ±2%n+2Resolution: 0.1/1PC interface: RS232C (Cable & software are optional)Can memorize 50 group dataAuto power offPower supply: 4x1.5V AA A (UM-4) batteryBattery indicator: low battery indicatorDimensions: 156x67x28mm
-
product
Ultrasonic Flow Meters
Omega ultrasonic flow meters are ideal for liquid flow measurement as a permanently installed meter, a temporarily installed meter, or as a portable flow verification device.
-
product
Process instrumentation
Conductivity measurement
The ISL05x inductive conductivity sensor with internal temperature compensation enables precise and rapid measurements in many different applications in the pharmaceutical and food and beverage processing industry. Its reaction time is < 3 s and it is always excellent, even with very low conductivity and low levels of flow. It reliably prevents any traces being left of damaging CIP and SIP fluids, which in the worst case could get into the product.
-
product
Suitable For Frequency And Pulse Sensors
SEM1600F
The SEM1600F is a cost effective “smart” powered conditioner that accepts all common process pulse signals with a frequency range between (0.01 to 65000) Hz in standard configuration and (DC to 1000) Hz in counter mode. Typical applications would be to measure flow or batch counting.
-
product
RS-422/RS-485 Repeater
ND-6510
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Syringe Pump
500xv
The 500xv is able to pump higher viscosity material by reducing the restriction within the pump, specially designed with 3/8” ports at a 45 degree angle. Ball valves are used for automating refill and continuous flow which clear easily.The 500xv syringe pump provides precise delivery of high viscosity material up to 204 mL/min. Pulse-less flow is delivered up to 5,000 psi (345 bar) for pumping thick materials. Viscosity can be reduced by heating the pump chamber. A Temperature Control Jacket can be used to raise the temperature above ambient up to 100 ◦C.The High Temperature package allows the ability to heat up to 200 ◦C.The SyriXus controller has backlighted keypad and 4-line LCD display, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly. Control the pump remotely using driver for LabVIEW™ software, in addition to pump controller.The 500xv pump module has a single-ratio drive train with auto-lubricating gears for long life and low maintenance. Special fittings are used to prevent leaks and ensure safety at maximum pressure.
-
product
Measurement System For Testing & Binning Of Back-End LEDs
TP121-TH
The photometric specifications of LEDs must meet very high tolerance requirements regardless of whether they are to be used in general, automotive or other specialist lighting applications. This is often a problem since the manufacturing tolerances of LEDs can be higher than those permitted in the end-use applications. Also, LED binning by LED manufacturers in order to classify LEDs based on their tolerances is performed with flash mode testing using pulsed current flow. However, end-use applications of the LEDs often operate in constant current mode and with significant thermal effects. The sophisticated LED processing industry therefore requires measurement devices that can be used for both manufacturer-compliant pulsed mode, as well as constant current operation mode. When the LEDs are run in constant current mode, the junction temperature has significant influence on the performance and lifetime of the LED. Therefore, test systems should be able to test the LEDs at specific junction temperatures.
-
product
CEMS
FMD 09
IMR Environmental Equipment, Inc.
The continuous measurement of velocity and temperature of gas flows is much important at operation of a system with flowing gases (e.g. hall outlet air, exhaust etc.).
-
product
LGA 1200 Intel® Xeon® W & 10th Gen. Core™ ATX Server Board with 4 x DDR4, 5 x PCIe, 2 x PCI, 6 x USB 3.2, 5 x SATA 3, Quad/Dual LANs, and IPMI
ASMB-787
- LGA 1200 Intel® Xeon® W & 10th Gen. Core™ i9/i7/i5/i3 processors with W480E chipset- DDR4 2933/2666/2400 MHz ECC/Non-ECC UDIMM up to 128 GB- One PCIe x16 link (or two x8 link), two PCIe x4, and one PCIe x1 slots- Triple displays - DVI-D, VGA, and HDMI 2.0 ports- Five SATA 3 ports and six USB 3.2 ports- One M.2 2280/2242 (SATA / PCIe compatible)- Rackmount optimized placement with positive air flow design- 0 ~ 60 °C (32 ~ 140 °F) ambient operating temperature range
-
product
PCIe Gen3 High speed, compact Camera for Testing
CB013MG-LX-X8G3
High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
Integrated Display Type Digital Flow Sensor
FM-200
Panasonic Industrial Devices Sales Company of America
Panasonic offers a Digital Flow Sensor with integrated display for a wide range of applications. The FM-200 Series can control and effectively manage flows using a variety of output modes.
-
product
Melt Flow Indexer
MFI-01
Jinan Leading Instruments Co., Ltd.
MFI-01 MELT FLOW INDEXER is usedto test the thermoplastic polymer flow properties in the viscous flow state. Itis used to determine the melt flow rate of thermoplastic resin(MFR)and Melt volume flow rate (MVR). It is not only applicable for the material such aspolyethylene, polystyrene, polypropylene, ABS resin and lowmolten emperature, but for polycarbonate, poly-oxide, fluorine plastic, nylonwith high molten temperature.
-
product
Detailed Hydrocarbon Analysis
The purpose of detailed hydrocarbon analysis (DHA) is to determine the bulk hydrocarbon group type composition (PONA: Paraffins, Olefins, Naphthenes and Aromatics) of gasoline and other spark-ignition engine fuels that contain oxygenate blends (Methanol, ethanol, MTBE, ETBE, and TAME) according to ASTM-D6730. PONA analyte identification is conducted by matching retention indices with normal hydrocarbon paraffins. However, chromatograms obtained in PONA analyses have an extremely large number of peaks and their analytes may be mislabeled. Without accurate and reproducible retention indices, this may result in erroneous PONA ratios. The GC-2030 incorporates an Advanced Flow Controller that enables highly precise flow control, and makes it easy to analyze and identify detailed hydrocarbons. Shimadzu offers DHA analysis conforming to the following methods: ASTM-D5134, ASTM-D6729, ASTM-D6730, and ASTM-D6733.
-
product
5G NR Automation Test Tool
IQfact5G
IQfact5G ensures quality device characterization and facilitates easy customization of test flow, thus significantly reducing engineering effort.
-
product
Gas Flow Standards
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
product
Multiple-Input Multiple-Output (MIMO) FRF Testing
EDM Modal MIMO FRF Testing includes a dedicated test setup and operation process flow using multiple simultaneous shakers to acquire FRF signals. Using a large channel count data acquisition system (i.e., Spider- 80X or Spider-80Xi), this shaker excitation method provides much higher efficiency and accuracy for the FRF measurements while minimizing local stresses on the test article.
-
product
Flow Cytometry
The iQue® Advanced Flow Cytometer allows researchers to acquire and analyze high content, multiplexed assays needed to assess immune cell function by combining cell immuno-phenotyping, cell health, and secreted protein (cytokine) analysis in every well of a microtiter plate. Accelerate your research by resolving complex cellular research questions via multiplexed analysis in a single well.