Rack Mount Thermometer Hygrometer
H3531R
Sensor H3531R is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
HVAC/R Environmental Meter
FLIR EM54
The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.
-
product
Temperature and Humidity Regulator
H3331
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
Temperature and Humidity Regulator
H3430
Built-in relative humidity, temperature sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
temperature, humidity, bar. pressure transmitter
T7410
Built-in relative humidity, temperature, atmospheric pressure sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Thermo-Hygrometers
PeakTech Prüf- und Messtechnik GmbH
3 in 1 IR temperature / humidity meter with digital multifunctional LCD display and background lighting for simultaneous display of humidity, temperature, dew point and wet temperature. It can be used in the areas of refrigeration and air conditioning, plant construction, the construction industry and for general heat treatment processes in the metal, electrical and chemical industries.
-
product
Temperature and Humidity Bar Type Probe
T3117
Relative humidity, temperature sensors at 700mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Temperature, Humidity, CO2 Transmitter
T6440
The transmitters are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature andrelative humidity are recomputed to following humidity expression: dew point temperature, absolutehumidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Temperature, Humidity, CO2 Transmitter
H6420
The regulators are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature andrelative humidity are recomputed to following humidity expression: dew point temperature, absolutehumidity, specific humidity, mixing ratio and specific enthalpy
-
product
Temperature and Humidity Regulator
H3431
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
Dew Point Monitor
DPM-99
The NFPA99 has mandated that for Med Gas systems the "dew point for locally compressed air shall be monitored and alarmed per 4-3.1.9.8 and 4-3.1.1.2(f) to protect from line pressure dew point rise to 39 degrees F (3.9 degrees C) from a nominal design of 35 degrees F (1.7 degrees C)." This safeguard was the foundation for the new Edgetech Instruments DPM-99 Med Gas Dew Point Monitor. This specifically designed monitor exceeds the requirements set forth by the NFPA and was a collaboration with AIRVAC Technical Services who are certified by P.IP.E as medical gas inspectors in all 50 US States.
-
product
Web Sensor Hygrometer
T3511-4
Web Sensor with relative humidity and temperature probe. The device is supplied with T+RH probe on the cable.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Dewpoint Meter
319
A hand-held dewpoint meter with both manual and automatic data logging in one gaugeIntegrated magnets allow the dew point gauge to be attached to the substrate during remote loggingStores 25,000 records in up to 999 batchesDustproof and waterproof gauge with fully sealed sensors (equivalent to IP66)Gauges can be recertified at Elcometer Authorised Service CentresRobust temperature sensorsEasy to use, intuitive menu structureMeasure and record climatic parameters:Relative humidityAir temperatureSurface temperatureDewpoint temperatureTΔ (the difference between surface temperature and dewpoint)Dry Bulb temperatureWet Bulb temperatureExternal temperature correction (K-type)Specific HumidityVisual and audible indication of user defined limits for any or all parametersUSB and Bluetooth® data output to ElcoMaster® software
-
product
Compressed Air Temperature and Humidity Regulator
H3061P-2
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Web Sensor
T7511-4
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Temperature, Humidity, Pressure Regulator
H7430
Built-in relative humidity, temperature, pressure sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
Vigilant Aircraft Hygrometer
137
The Edgetech Instruments Model 137 Vigilant Aircraft Hygrometer is a rugged, shock mounted military qualified instrument used for the primary measurement of dew point in flight or in installations with existing flow, such as wind tunnels.It features a miniature remote dew point sensor employing a platinum resistance thermometer, and has 15 feet of interconnecting cable to the control unit. Precision calibration units for the linear analog outputs are included.
-
product
Hygrometer with 3 Stage Thermoelectric Cooler
CR - 4
Buck Research Instruments, LLC
The CR-4 is a chilled mirror hygrometer that uses a 3-stage thermoelectric cooler (TEC) to enable frost point measurements of as low as - 65C, under favorable ambient conditions. Depending upon ambient temperature, it can measure dew points as high as 60C.
-
product
RH+T+Tdp Outdoor, Indoor Probe
T3411
Relative humidity, temperature sensors on the cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Temperature and Humidity Regulator
H3331-4
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
Relative humidity, temperature sensors
T3111
Relative humidity, temperature sensors at probe on 1 meter cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Handheld Humidity/Temp Hygrometer
625
The Model 625 is an ideal instrument for indoor air quality (IAQ) and indoor environmental quality (IEQ) measurements of temperature and humidity. The EdgeTech 625 temp/RH probe can be used two ways: use it as an integrated unit by attaching the probe head to the instrument or connect both parts via a cable. The clear back-lit display can be switched between relative humidity, wet bulb, and dew point at the touch of a button.
-
product
Indoor Air Quality Monitor
2212
The Kanomax Indoor Air Quality Monitor – Model 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments. It simultaneously measures multiple parameters such as: CO, CO2, Temperature, and Relative Humidity. It is capable of calculating Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air. Calibration is easy and can be done by the user.
-
product
Calibration Services
for Humidity, Dew Point, Trace Moisture and Temperature Measurement Instruments
-
product
Hygrometer
UHQ-4P
Buck Research Instruments, LLC
The UHQ-4P is a chilled mirror hygrometer that is designed for measuring elevated dew points, such as those found in fuel cell and combustion applications Using technology developed for the CR-1A, CR-2 and CR-3, this instrument is unique because it does not use TE coolers to cool the mirror and thus is extremely fast and can handle very high temperatures. The UHQ-4P can measure dew point up to 150°C at pressures up to 150 psia (10 bar). It can display %RH with an optional ambient temperature sensor. The UHQ-4P is designed to measure in hydrogen, air and most non-corrosive gases at pressures ranging from near vacuum to up to 150 psia (10 bar).
-
product
Temperature and Humidity Regulator
H3431-2
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
product
Rack Mount Thermometer Hygrometer
H3531R-4
Sensor H3531R is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
All-in-One Meteo Compact Station
HDMCS-200
A ready to use and easy to set up Automatic Weather Station. The AWS measures wind speed, wind direction, humidity, dew point, temperature, barometric pressure and solar radiation.
-
product
Compressed Air Temperature and Humidity Regulator
H3021P-2
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Portable Sulphuric Acid Dewpoint Temperature Monitor
The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.