Winding Resistance
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Transformer Winding Resistance Testers / TRT ? 27
TRT-27 series
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 2.5A to 20A, Digital display of resistance and test current.
-
Product
Winding Resistance Meter 100Amps, 2 Channels
WR100-12R
-
Raytech Digital Winding Resistance meter WR100-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Meter 50Amps, 2 Channels Rack
WR50-12R
-
Raytech Digital Winding Resistance meter WR50-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Meter
-
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
Transformer Winding Resistance Testers / TRT ? 2
TRT-2
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 0.02A to 2A DC, Digital display of resistance and test current.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Winding Resistance Meter
TRM 50+
-
SCOPE introduces 50 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 50 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Winding Resistance Meter 15Amps, 2 Channels
WR14
-
Raytech's Digital Winding Resistance meter WR14 is the battery powered version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy measurement of very low resistance of any inductive loads.
-
Product
Transformer Winding Resistance Meters
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
Product
Resistance Measuring Equipment
-
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
Product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
-
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
Product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
-
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Portable Winding Resistance Tester
-
1. Handheld winding resistance meter2. Conversion function for standard temperature resistance.3. 500 test data can be saved and download by flash disk.4. Temperature testing function.
-
Product
DC Resistance Tester
GDZRS-20A
-
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
Product
Passive Component ATS
-
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Micro-Ohmmeters
-
Micro-Ohmmeter is an affordable 7 range, 4-Wire Kelvin based product that is used to test electrical resistance on a wide variety of applications including winding resistance, contact resistance, and component testing. The 720A micro-ohmmeter has an autorange feature (available with NSN package) and is compatible with an RS232C interface (OP-232). Thanks to its wide-range capabilities, ease of use, and CE mark, this micro-ohmmeter is used commonly across the globe.
-
Product
Microohmmeter
MMR-6700
-
The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
Product
Switch Module
STCS
-
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.