Compensators
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0104
-
The AWS-0104 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and single beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain during transmit mode, 21dB gain in receive mode, +15 dBm output power during transmit, and 3.4 dB NF during receive. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 QFN for easy installation in planar phased array antennas.
-
Product
Infrared Thermometer
DITH 120
-
Infrared Thermometer is also known as laser thermometerInfrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.Laser is used to help aim the thermometer or non-contact thermometers or temperature guns, to describe the device's ability to measure temperature from a distance. By knowing the amount of infrared energy emitted by the object and its emissivity, the object's temperature can often be determined. Infrared thermometers are a subset of devices known as "thermal radiation thermometers".The design essentially consists of a lens to focus the infrared thermal radiation on to a detector, which converts the radiant power to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature. This permits temperature measurement from a distance without contact with the object to be measured. A non-contact infrared thermometer is useful for measuring temperature under circumstances where thermocouples or other probe-type sensors cannot be used or do not produce accurate data for a variety of reasons.
-
Product
High performance multisensor
Werth StentCheck®
-
High performance multisensor CMM with Integrated Werth Zoom® optic with magnification 0.7x – 6.8xRotary/Tilt Axis with high speed air bearing rotary axisRotary OnTheFly for fast measurementsContour image processing for fully automatic measurements of complex geometrical elements with sub-micron repeatabilityIntegrated goniometer (tilting axis) allows for the measurement of non-cylindrical geometriesUnique lighting design optimized for measurement of stentsTemperature compensation included
-
Product
EIS Battery Analyzer
BA8100
-
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
Product
CO2 Concentration
H5524
-
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
-
Product
Isocratic Pumps - Single Headed, Positive Displacement Piston Pumps
ReaXus MX Class
-
The economical MX Class consists of single-headed, positive displacement piston pumps incorporating additional features for challenging applications. With pressure capability up to 5,000 psi, the MX Class can be used in both analytical and smallscale preparative HPLC separations. Further applications include demanding metering and dispensing, as well as Sample Injection, Infusion, or Cone Wash for Mass Spectrometers. Standard fluid path material is Stainless Steel.Features include available pressure monitoring with automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232 and Micro USB 2.0 ports. Requiring minimal bench space for the performance, the MX Class will easily integrate into most workspaces.
-
Product
Search Receiver
KMF 1
-
Cable fault location with the BAUR KMF 1. The KMF 1 search receiver is used according to the step voltage method. The cable line is scanned with two measurement probes that can be dismantled during transport. The battery-operated device is also suitable for locating multiple consecutive sheath faults.* Battery mode* Zero point compensation* accurate location of cable sheath faults* battery test
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
TAP Extender
JT 2135
-
The JT 2135 allows TAP signals to be extended away from the base JT 2137 (classic pod) by up to 1 meter and retain full pod’s frequency specifications. The active circuitry inside the JT 2135 compensates for the TDO signal return time of the longer interface cable. Multiple JT 2135s can be implemented if a longer extension is required.
-
Product
Ultrafast Laser Pulse Measurement
FROG Scan
-
Our FROG Scan system is versatile, adaptable and easy to use. With our FROG Scan, you can tweak a laser system or measure highly chirped pulses to calculate the amount of dispersion compensation you might need for recompression. Measure a short pulse that has been chirped out to several picoseconds, or measure pulses as short as 12 fs in real-time.
-
Product
Current Transformers & Bushings
-
Measurements International Ltd.
AC Current Transformer, Reference Standard for the Calibration of Precision CTs, Currents as high as 10,000 A, Portable with carrying handle for smaller CTs, Wheels on heavier CTs, Passive or Electronically Aided Compensation.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
High Power DC Power Supply
-
*Low ripple and low noise*High resolution and accuracy (0.1mV/0.01mA)*Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter*Supporting high-accuracy and dynamic programming output*High-luminance VFD screen with two lines& four channels display*Intellegent fan system fan will be automatically initiated according to the temperature*Supporting remote voltage compensation and multidata storage*Supporting external trigger input and output*Power-on-self-test, software calibration and standard rack mount*Using standard SCPI protocol*Communication mode: RS232/RS485/USB.
-
Product
Isocratic Pumps - Single Piston, Positive Displacement Piston Pumps
ReaXus LS Class
-
The reliable ReaXus LS Class consists of single-headed, positive displacement piston pumps incorporating advanced cam designs for very low pulsation.The pumps are ideal for a wide variety of applications, Semi-Prep LC, metering & dispensing, and general laboratory use. Standard fluid path materials are Stainless Steel with PEEK options. Other available features include jacketed heads for temperature controlled processes. With 5 mL/min, 10 mL/min, and 40 mL/min versions available, and pressure capability up to 6,000 psi, these versatile pumps will meet the most demanding applications.Features include automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232 and Micro USB 2.0 ports. The unique LS Class provides the highest performance/cost ratio in a compact package.
-
Product
HVDC Power Filter Characteristic Test Set
FT3000
-
FT3000 Power Filter Characteristic Testing equipment has the functions of automatic sweep harmonic signal output, A-F and P-F characteristic measurement/display etc. It can perform HVDC Power Filter Testing and is mainly used in AC filter of DC convertor station, DC filter tuning characteristics test and parameter test of R, L and C. It is also used in electrified railway HV filter, passive power filter client and conventional AC substation reactive compensation device.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
SparkFun Breakout
HMC6343
-
The HMC6343 is a fully integrated high end electronic compass module that can compute and give you a heading direction that’s accurate within a couple degrees. It is tilt compensated and is calibrated to handle magnetic distortions. This breakout board allows for easy use of the HMC6343. All that is required is power and I2C connections to a microcontroller so that the module can receive commands and send data back to the user.
-
Product
Battery Chargers
-
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Bluetooth® Enabled PH And Temperature Pen
UltrapenX2™ PTBT2
-
*Accuracy of ± 0.01 pH*1, 2 and 3 Point Calibration*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type battery (Included)*Waterproof
-
Product
EDFA Amplifier
-
A line of Gain Flattening Erbium-Doped Fiber Amplifiers are designed for in-line amplification of DWDM networks. When a standard EDFA is used to amplify multi-channel DWDM signals, the output power level of various channels will vary according to the gain profile of the erbium fiber. This gain variation can be as great as 6 dB in magnitude. The EDFA-GB-R is unique in its dual-stage amplification and internal Gain Flattening Filter (GFF) to compensate the erbium fiber gain variation.
-
Product
Personal Dose Alarm Meter
DP802i
-
DP802i type X - gamma radiation detector - as a super humanized design and enhanced personal dose monitoring is mainly used for X, gamma rays and hard beta rays of radiation protection monitoring, suitable for nuclear power station, the accelerator, isotope applications, industrial X, gamma NDT, radiation source treatment, medical treatment, cobalt gamma irradiation, radioactive laboratory, nuclear facilities around environmental monitoring field, timely, ensure to my warning safety of staff; The instrument can be also measured dose rate and cumulative dose. It USES reactive new single chip microcomputer, the compensation for the probe, the instrument GM counting pipe has a wide measurement range, better energy response characteristics, and with overload directives and protection function.
-
Product
Barometers
-
Ideal for recording ambient changes in lab, monitoring conditions affecting sample analysis, and assisting in prediction of weather changesUnit includes a barometer, thermometer, clock, altitude adjustment, and weather symbol forecasting symbolsAdjustable altitude compensation from –900 to 3600 feet (–300 to 1200 meters)Barometric trend shows current reading, previous 1, 3, 6, and 12-hour readings in bar chart f
-
Product
Industrial Resistivity Meter
HE-480R(W)
-
The HE-480R industrial resistivity meter features the high-precision temperature compensation function.Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields, including the areas of electrical goods, foods and medicines. The measurement range is from 0 to 100.0 MΩ・cm.
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
HDG and OBS Track Select Panel
TA-260
-
Universal Heading and Track Selector Panel This panel provides a synchro transmitter for Heading and a synchro resolver for Nav converter alignment. The synchros are mounted on industry standard 18:1 dual speed drives for maximum accuracy and repeatability. This unit can be used to calibrate both manual and automatic converters. This panel provides a rear mounted interface connector as well as front mounted tip jacks for independent breakout if so desired. The TA-260 also provides two discrete switches associated with the resolver configuration. The 30Hz/400Hz switch is provided to allow the resolver to be properly compensated for the type of Nav converter to be aligned. The second switch allows you to open or short the resolver rotor lead as may be required by some newer GPS equipment. This panel is lightweight enough for portable use or may be rack mounted.
-
Product
pH 5+ Handheld pH Meters
-
These meters are perfect for fast, accurate results. Automatic temperature compensation (ATC) ensures accuracy from 0 to 80°C. Meters include a protective rubber boot that also acts as a meter stand.
-
Product
Thyristor Switches
SC Series
-
SC Series Thyristor Switches are used in systems which contain fastswitching inductive loads. The capacitors, which will be used to provide capacitive power to the system, can be switched on and off with a switching time shorter than 20 ms (1 period) by using SC Series Static Contactors, thereby providing a more effective compensation for fast-switching loads such as tack welding machines, cranes and arc furnaces.




























