Mixers
-
Product
Mixers
-
Teledyne Microwave Solutions (TMS) offer a wide range of both double & triple balanced mixers for many different applications from commercial test equipment to space qualified units. Low conversion loss and wide bandwidths are the hallmark of the product line. The incorporation of Schottky diodes on some designs offers significant performance benefits.
-
Product
Harmonic Mixers
-
These waveguide bandwidth harmonic mixers are designed for use with spectrum analzyers with diplexers, such as the Tektronix 492 and 494 and the Hewlett-Packard 8555A, 8565A and 8569A. They are also used as phase locking and receiver mixers for antenna measurement systems such as the Scientific Atlanta wide range receivers. When used with an external diplexer*, these harmonicmixers can be used to phase lock millimeter wave sources.
-
Product
Smart Harmonic Mixers
-
These smart mixers use a simple USB plug-and-play connection which can automatically configure the signal analyzer for the specific mixer connected, including downloading conversion loss data and automatically compensate for local oscillator path loss. Therefore, it provides you with the most efficient test setup, shortening the overall start up operations with better performance with its embedded smart features when used with Keysight EXA, PXA, MXA, and UXA signal analyzers.
-
Product
Emulsion Mixers
4818
-
Parker Conflow’s Code 4818 is a unique emulsion mixer which supplies a constant, accurate mix ratio of soluble oil and water to provide fire-resistant hydraulic fluid to power roof supports on the coal face.
-
Product
Mixers
FS-Z
-
RPG offers broadband harmonic mixers with an integrated isolator (50 – 220 GHz) for optimum RF matching. Hence standing waves, usually degrading RF power measurement accuracy, are suppressed.
-
Product
RF Mixers with Integrated LO
-
Analog Devices RF mixers/multipliers include both active and passive, as well as broadband and narrowband, products. These devices promise high performance and flexibility to help designers achieve their target specifications, reduce design time, and optimize costs. With leading specifications including speed, dynamic range, noise figure under blocking, SFDR, and ESD performance, ADI RF mixers and multipliers help to raise the bar within RF systems.
-
Product
Mixers
EHM and SHM
-
VDI offers subharmonically-pumped mixers (SHM) and even-harmonic mixers (EHM) for a variety of applications between 50 GHz and 1700 GHz. These mixers use only planar and/or integrated diodes and provide state-of-the-art performance.
-
Product
Mixers
-
Applied Research and Technolgy
USB mixers, rackmount zone mixers, and compact solutions for studio recording and live performance.
-
Product
Waveguide Harmonic Mixers (smart mixer), 60 to 90 GHz
M1970E
Harmonic Mixer
The Keysight M1970E 60 to 90 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of the N9030A PXA, N9020A MXA,and N9010A EXA signal analyzers up to 90 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
Gas Mixers / Gas Blenders
-
WITT offers high-quality gas mixers and gas dosing systems for two or more gases, especially for high and strongly fluctuating gas mixture flow rates.
-
Product
RF Mixers & Frequency Converters Overview
-
Up and down conversion is often used because waveform generation in a transmitter is less expensive at lower frequencies and the dynamic range of analogue-to-digital converters in the receiver is higher at lower frequency.
-
Product
Hot Electron Bolometer (HEB) Mixers/ Receivers In Terahertz Range
-
Insight Product Company offers Hot Electron Bolometer (HEB) mixers, receivers, and chips made from NbN or NbTiN thin film. The HEB mixers can operate at frequencies of up to several terahertz.
-
Product
Image Reject Mixers To 16 GHz
-
Image Reject Mixers incorporate a 2-way 0° divider, two 90° hybrids and two mixers. They produce an IF signal when driven by an LO and RF signal while rejecting unwanted sidebands that are very close in frequency.
-
Product
Single, Double & Triple Balanced Mixers
-
Analog Devices portfolio of single, double, and triple balanced mixers offers the most fundamental and versatile frequency mixing components to meet the varied needs of RF, microwave, and millimeter wave applications. This product family helps designers meet their specific design objectives, and ADI offers a wide range of mixers with both die and packaged options available.
-
Product
Waveguide Harmonic Mixers (smart mixer), 75 to 110 GHz
M1970W
Harmonic Mixer
The Keysight M1970W 75 to 110 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of N9030A PXA, N9020A MXA,and N9010A EXAsignal analyzers up to 110 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve your DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
Components - Subharmonic Mixers (SPM)
SPM Series
-
Farran offers fundamental (RF ≈ LO), sub-harmonic (RF ≈ 2xLO) and harmonic mixers (RF≈NxLO, where N=2, 4, 6 …) for a wide variety of applications from 26.5 GHz to 500 GHz. All mixers use planar Schottky diodes and provide state of the art performance in a small and lightweight package.High-performance sub harmonically pumped mixers are available in frequencies from 50 to 350 GHz and beyond.
-
Product
RF Mixers
-
An RF mixer is a three-port passive or active device that can modulate or demodulate a signal.
-
Product
Triple Balanced Mixers From 0.05 To 4200 MHz
-
A triple balanced mixer uses two well matched quad-diode rings. Because of this, they offer wider LO/RF bandwidths than DBM designs. But more importantly, the TBM offers a higher dynamic range and lower distortion.
-
Product
Waveguide Harmonic Mixers (Smart Mixers), 55/60 to 90 GHz
M1971E
Harmonic Mixer
Keysight M1971E 55/60 to 90 GHz waveguide harmonic mixers is an un-preselected mixer provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
In-line Plastic Mixers
-
Ideal for one-use fluid dispensing, Nordson EFD’s disposable static mixers eliminate the need to worry about premature curing of materials.
-
Product
Mixers
-
Teledyne RF & Microwave offers a wide range of both double & triple balanced mixers for many different applications from commercial test equipment to space qualified units. Low conversion loss and wide bandwidths are the hallmark of the product line. The incorporation of Schottky diodes on some designs offers significant performance benefits.TWe have many packaging options and with over 400 ITAR-free designs, we are able to offer the right mixer for your demanding application.
-
Product
I/Q and Image Reject Mixers
-
In-phase quadrature (I/Q) mixers and image reject mixers (IRM) offer a robust frequency mixing solution for applications that require high image rejection or sideband suppression. These mixers can be used as an upconverter or downcoverter. I/Q or IRM mixers use two double-balanced mixers with a 90° hybrid. The inherent architecture of I/Q mixers eliminates the resulting product due to image frequency during downconversion and allows the selection of desired sideband during upconversion.
-
Product
Spectrum Analysis For E5081A Up To 44 GHz
S960907B
-
The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.





























