Hysteresis Loop
describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
Product
AC Hysteresis Graph Test System
DX-2012SA
-
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
Product
Fluxmeter
-
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
Product
DC Hysteresis Graph
DX-2012SD
-
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.
-
Product
Vibrating Sample Magnetometer
VSM
-
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
Product
AC Hysteresis Graph Test System
DX-2012M
-
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
Product
Soft Iron Tester
WP2
-
Computer aided measuring set for automatic measurement of the hysteresis loop of soft magnetic materials. Allows measurement of workpieces with different length and cross sections.
-
Product
Material Science Laboratory Instruments
-
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
Product
Magnet Tester
MP
-
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
Product
Hysteresis Loop Tracer
MESA
-
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
Product
Automatic Hysteresis Graph Test System
DX-4DMT
-
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
Product
Hysteresis Graph
-
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic material parameters using hysteresis graphs is of utmost importance for both material manufacturers and users. Discover the hysteregraphs from MAGNET-PHYSIK in Cologne.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Single Loop Controller
1166
-
The 1166 is a powerful, single loop profile controller for complex processes. It offers profiling capability with 4 programs each of 16 free format segments making it a leader in its class.
-
Product
Loop Antennas
-
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Phase Locked Loop with Integrated VCO
-
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
Product
Dual Loop Master Controller
-
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
Product
ThePoint - Loop Powered Level Switch
-
ThePoint Loop Powered two wire level switch provides a current output and has hazardous area approvals making it a good choice for most of your point level application requirements. ThePoint level sensing device offering is suitable for most temperature, pressure, and material types.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Hysteresis Dynamometers
HD Series
-
16 Standard Models with Maximum Torque from 2.5 ozin to 500 lbin (18 mNm to 56.5 Nm)Hysteresis Braking System: Provides precise torque loading independent of shaft speedMotor Testing from No Load to Locked RotorAccuracy: 0.25% to 0.5% (Full Scale)Air Flow Sensor: For protection against overheating and operator errorStandard Torque Units: English, Metric and SIBase Plate: Available in long or short versionsCustom Dynamometers: for special torque and speed requirementsEasy Calibration
-
Product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
-
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
Product
Friction Flow Loop System
-
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
Product
Loop / PFC Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Loop A Line Products
-
Cable pair tracing and a lot more, Loop-a-Line products can remotely control a far end device (the oscillator) for up to 20km of cable. Using a Loop-a-Line allows the linesman to remotely change the state of the oscillator to any of five different states. Therefore eliminating the need for multiple journeys along the cable path.
-
Product
Active Loop Antenna
KH30935
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH30935 active loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna has a small outer diameter and light weight, which is convenient for outdoor measurement.
-
Product
Floating Power FET moduleAmp Loop
PFM1010
-
The PFM1010 Module is a precision instrument capable of measuring all common DC parameters in a power MosFet as well as many of the AC parameters. This module uses some very innovative techniques to make it possible to measure parameters like Rdson down into the sub-million-ohm range.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
-
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.




























