Hysteresis Loop
describes the induced magnetic flux density (B) in relation to the magnetizing force (H). Also known as: BH Loop
See Also: Hysteresis, Hysteresis Graphs, Hysteresis Curve, Core Loss, Flux Density, BH Curve
-
Product
Hysteresis Loop Tracer
MESA
-
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
Product
Soft Iron Tester
WP2
-
Computer aided measuring set for automatic measurement of the hysteresis loop of soft magnetic materials. Allows measurement of workpieces with different length and cross sections.
-
Product
DC Hysteresis Graph
DX-2012SD
-
Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.
-
Product
Fluxmeter
-
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
Product
Material Science Laboratory Instruments
-
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
Product
AC Hysteresis Graph Test System
DX-2012SA
-
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
Product
Automatic Hysteresis Graph Test System
DX-4DMT
-
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
Product
Magnet Tester
MP
-
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
Product
Vibrating Sample Magnetometer
VSM
-
The VSM (also named M-H CURVE Hysteresis Graph TEST SYSTEM ) can be used for the measurement of the basic magnetic properties of the magnetic materials. Such as the Hysteresis loops of the materials, Magnetization curve, Warming Curve , Warming /Cooling curve, Cooling curve and the changes of the temperature as time goes away , then we will get some Magnetic parameters such as the Saturated strength of the magnetization, the left strength of the magnetization , Coercive force, the Max of Magnetic energy product,the Curie temperature and the Magnetic conductivity(the Initial Magnetic conductivity is included ). It can also measure the magnetic materials such as the powder, the particles, the films, the liquid and the massive.
-
Product
AC Hysteresis Graph Test System
DX-2012M
-
Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
-
Product
Hysteresis Dynamometers
HD Series
-
16 Standard Models with Maximum Torque from 2.5 ozin to 500 lbin (18 mNm to 56.5 Nm)Hysteresis Braking System: Provides precise torque loading independent of shaft speedMotor Testing from No Load to Locked RotorAccuracy: 0.25% to 0.5% (Full Scale)Air Flow Sensor: For protection against overheating and operator errorStandard Torque Units: English, Metric and SIBase Plate: Available in long or short versionsCustom Dynamometers: for special torque and speed requirementsEasy Calibration
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Single Loop Controller
1462
-
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
Product
Loop / PFC Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
-
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
Product
Loop Meter
MZC-310S
-
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
Product
Loop powered Moisture Analyzer
PLMa
-
Multifunctional Multi-Purpose Cost Effective, easy-to-use dew point sensor, dew point probe
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Temperature Loop Control Setup
ULP-27
-
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
Product
Single Loop Controller
1400+
-
The 1400+ controller is an evolved product from the West N4100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
Digital Phase Locked Loop (PLL)
A6-CPS
-
The A6-CPS digital phase locked loop (PLL) can be customised to a specific application and shipped ready for use in production.
-
Product
Loop A Line Products
-
Cable pair tracing and a lot more, Loop-a-Line products can remotely control a far end device (the oscillator) for up to 20km of cable. Using a Loop-a-Line allows the linesman to remotely change the state of the oscillator to any of five different states. Therefore eliminating the need for multiple journeys along the cable path.
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.
-
Product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
Single Loop Controller
1160+
-
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
DDS Phase Locked Loop Synthesizer
DDS Series
-
*Connectorized Package *Programmable Frequencies to 1 GHz
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
U Type Glow Wire Loop
IEC60695-2-10
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.




























