Pulse Current
-
Product
Split type Pulse Current Sensor
OKM-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For pulse current detection.
-
Product
Split type Pulse Current Sensor
CTF-05K
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Clamp type CT.*Open collector output.
-
Product
Split type Pulse Current Sensor
CTF-05M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Through hole type CT.*Open collector output.
-
Product
AC/DC Power Capacitors
ACF Series
-
For 70Vac~400Vac / 100Vdc~700Vdc Pulse Current requirement, please refer to our DC Pulse Current Capacitors for Power Electronic applications.For continuous and High RMS Current requirement, please refer to our High AC Current Capacitors LC series, which support continuous duty even at +105C.We manufacture AC Filter Capacitors for a wide variety of applications with different Capacitances, Voltages, Discharge Energy ranges, dv/dt, Pulse Discharge Currents, RMS Currents, frequency ranges, size restriction and even capacitor mountings.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-200B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Low Inductance BNC Cable, VOLT:DC 60V
PX0105A
Coaxial Cable
The Keysight PX0105A is suitable for narrow current pulse measurement down to 10 μs pulse width. It supports the Keysight M9602/03A.
-
Product
Condenser for General Applications
PECA1
-
Lifasa - International Capacitors, SA
These capacitors are designed for application in circuits in which they are subjected to non-sinusoidal voltages and pulsed currents, such as, for example, switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications in which a high life expectancy is required.
-
Product
Counter And Rate Meters
-
We carry a wide range of counter and rate meters including totalizers, batch controllers, and more. Available with pulse, magnetic or DC pulse, analog, voltage, current, and frequency input types.
-
Product
Power Cable Fault Locator
TM500
-
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
Product
Milliohm Meters
Chroma 16502
-
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
Product
TMR Current Sensors
-
MultiDimension Technology Co.,Ltd.
An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.3S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
Milliohm Meter
16502
-
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
Product
Condenser for General Applications
PECA2
-
Lifasa - International Capacitors, SA
These capacitors are designed for use in circuits where they are subjected to non-sinusoidal voltages and pulsed currents, such as switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications where a high life expectancy and a high RMS current are required.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20L-0.6S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
Transmission Line Pulse Testing
-
Transmission Line Pulse testing, or TLP testing, is a method for semiconductor characterization of Electrostatic Discharge (ESD) protection structures. In the Transmission Line Pulse test, high current pulses are applied to the pin under test (PUT) at successively higher levels through a coaxial cable of specified length. The applied pulses are of a current amplitude and duration representative of the Human Body Model (HBM) event (or a Charged Device Model – CDM – event in the case of Very Fast TLP, or VF-TLP).
-
Product
AMIDA VCSEL Tester
-
AMIDA VCSEL tester can be divided into three parts: LIV measurement system, Near Field measurement system and Far Field measurement system. To achieve the above three measurements, in addition to the necessary optical components and optical instruments, the core technology is to provide fast and stable current pulses to drive the VCSEL laser diode to emit light, and then to test various optical and electrical properties
-
Product
Pulsed Source Measure Unit
-
The SpikeSafe SMU is a precision pulsed source measure unit that precisely sources pulsed current and simultaneously digitizes voltage. Optimized for precise and repeatable high-power LED and laser testing, SpikeSafe™ SMU (Source Measure Unit) current sources deliver precise pulsing with low microsecond rise times, low-jitter triggering and integrated digitizer for more accurate and repeatable high-power LED and laser testing.
-
Product
High Voltage Film Capacitor
STHVF
-
We manufacture High Voltage Film Capacitors for wide variety of High Voltage power applications with different rated Capacitances, Voltages, Discharge Energy, dv/dt, Pulse Discharge Currents, RMS Currents, Frequency ranges, size restriction, temperature ranges and even capacitor configurations.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
Product
IC Side Channel Analysis
-
These probes allow you to couple fast, transient magnetic field, E-field, and current pulses into ICs.
-
Product
8 Channel Portable Data Acquisition Logger w/ 5" Touchscreen
Titan S8
-
The Titan S8 portable data acquisition logger combines industrial toughness with scientific accuracy to create a powerful, versatile standalone logger. In any environment, from the laboratory to the factory floor, the Titan S8 simplifies complex validation tasks with its eight input channels and a full-color, user-friendly touchscreen interface. No matter the task, the Titan S8 brings valuable, real-time temperature, pulse, current, and voltage data to users’ fingertips without any need for a PC. The Titan S8 is the ultimate companion for any service, equipment, or compliance engineer. Its handheld portability and shock absorbing boot empower users to bring powerful, instantaneous data acquisition wherever it is needed.
-
Product
Diode Laser Driver
D200
-
The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.
-
Product
Pulse Initialization Demo Board
TMR9112
-
MultiDimension Technology Co.,Ltd.
The TMR9112 demo board was developed to support evalution of the TMR9112 single-axis sensor. The demo board comes with the fast bipolar current pulsing circuit needed for initialising the TMR9112 sensor, and it can be powered from a USB port or any external 5V power supply. For user convenience, the demo board has an optional on-board timer clock with four selectable frequency settings. The On-board timer clock and frequency output can be enabled using the jumper pins. This demo board is divisable along the dotted line so that the sensor board can be seperated from the pulsing circuit board.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.6S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
High Current SMU Family 2000 A
AXC76xx
-
Generate very short, fully regulated current pulses from 2 ms to DC with up to 2000 A. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
High-Voltage Time-of-Flight Pulsers
-
Are high-voltage pulse generatorscapable of driving 50 (or higher) loads and operating over a wide pulse width range. The instruments include IEEE- 488.2 GPIB and RS-232 interfaces. For diode loads, thesemodels can be used to provide up to 1, 2, 4, 5 or 8 Amps of pulsed current if the diode is connected in series with 50. All models operate over a wide pulse width range of 100 nsto 100 us.
-
Product
Medium & High Voltage Pulse Generators (Rise Time > 1 ns)
-
Offer fast medium voltage pulsing with high current capability. These models are ideal for driving solenoids, pulse testing of MOSFETs, and other applications.
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Primary Cable Fault Locating
Directional Impulse Detector
-
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
Product
SpikeSafe DC / Continuous Pulsed Current Sources
-
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.





























