CWDM OADM Module(4,8,16,18-Channel)
-
Flyin Optronics' Coarse wavelength division multiplexer (CWDM Mux/Demux) utilizes thin film coating technology and proprietary design of non-flux metal bonding micro optics packaging. It provides low insertion loss, high channel isolation, wide pass band, low temperature sensitivity and epoxy free optical path.
-
Product
Coupler Workstations
-
Workstations using pure hydrogen gas from a tabletop generator, tank supply, or oxygen, can achieve high enough temperatures to develop Fused Biconic Tapered devices, Power Combiners, Wavelength Division Multiplexers, Thermal Core Expansion devices, and many other products.
-
Product
PXI 2 Amp MUX, Single 16-Channel 4-Pole
40-635-003
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 8-slot BRIC Multiplexer, 8-Channel, 40-Pole (4 Sub-cards)
40-570A-212
Multiplexer Module
The 40-570A-212 is a 8-channel, 40-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 10-Bank 26.5GHz SMA
60-801-310
Multiplexer Module
The 60-801-310 is a 6-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 22 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-132-E
Multiplexer Module
The 40-788-132-E (PXI) and 42-788-132-E (PXIe) are dual failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 13-Bank 40GHz SMA-2.9
60-802-413
Multiplexer Module
The 60-802-413 is a 4-channel, 13-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI Very High Density Mux 10 Ch 16 Pole
40-670A-022-10/16
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI/PXIe MEMS Optical MUX, Dual 2-Channel, Multi-Mode, 62.5/125 Fiber, ST Connectors
40-855A-522-M
Multiplexer Module
The 40/42-855A-522-M is a PXI/PXIe dual 2-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 50GHz, 50Ω, SMA-2.4
60-800-608
Microwave Multiplexer
Our 60-800-608 is a 8 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 1-Bank 18GHz SMA
60-802-201
Multiplexer Module
The 60-802-201 is a 4-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI Dual SP4T MUX 6GHz 50Ω SMA
40-784-102
Multiplexer Module
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI-2584 , 12-Channel, 600 V, 1-Wire PXI Multiplexer Switch Module
778572-84
Multiplexer Module
12-Channel, 600 V, 1-Wire PXI Multiplexer Switch Module —The PXI‑2584 is a high‐voltage PXI multiplexer switch module that is ideal for fuel cell and battery stack applications. The reed relays in the PXI‑2584 ensure longer lifetimes and faster actuation times for test equipment. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PCI 2 Amp Multiplexer, Quad 8-Channel, 1-Pole
50-635A-108
Multiplexer Module
The 50-635A-108 is a quad 8-channel, 1-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 8-Bank 18GHz SMA
60-802-208
Multiplexer Module
The 60-802-208 is a 4-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 6GHz, 50Ω, SMA, Remote Mount
40-784B-002-E
Multiplexer Module
The 40-784B-002-E (PXI) and 42-784B-002-E (PXIe) are dual SP6T 6GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe RF Multiplexer, Single 8-Channel, 3GHz, 50Ω, MCX
42-874A-101
Multiplexer Module
The 40-874A-101 (PXI) and 42-874A-101 (PXIe) are 50 Ohm 8 to 1 RF multiplexers with 1 bank in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
LXI Microwave Multiplexer, SP4T, 14-Bank, 26.5GHz, 50Ω, SMA
60-803-314
Multiplexer Module
Our 60-803-314 is a 14 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 13-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-513
Microwave Multiplexer
Our 60-800-513 is a 13 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber
40-852A-118-HI
Multiplexer Module
The 40/42-852A-118-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614B-014
Multiplexer Module
This 2-bank, 4-channel, 16-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18GHz, 50Ω, SMA
40-784B-022
Multiplexer Module
The 40-784B-022 (PXI) and 42-784B-022 (PXIe) are dual SP6T 18GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 4-Channel, 32-Pole
42-614D-020
Multiplexer Module
The 40-614D-020 (PXI) and 42-614D-020 (PXIe) 1-bank, 4-channel, 32-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 18GHz, 50Ω, SMA, Remote Mount
40-784B-021-E
Multiplexer Module
The 40-784B-021-E (PXI) and 42-784B-021-E (PXIe) are single SP6T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 67 GHz, 50 Ω, SMA-1.85, Failsafe
42-785C-472
Multiplexer Module
The 40-785C-472 (PXI) and 42-785C-472 (PXIe) are dual failsafe SP4T 67 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67GHz, 50Ω, SMA-1.85
40-785C-572-E
Multiplexer Module
The 40-785C-572-E (PXI) and 42-785C-572-E (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 26.5GHz, 50Ω, SMA, Remote Mount
40-784B-033-E
Multiplexer Module
The 40-784B-033-E (PXI) and 42-784B-033-E (PXIe) are triple SP6T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI 2A Multiplexer, 2-Bank, 8-Channel 8-Pole
40-614-013
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 6 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-102-E
Multiplexer Module
The 40-784B-102-E (PXI) and 42-784B-102-E (PXIe) are dual failsafe SP4T 6 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 5-Bank 6GHz SMA
60-801-005
Multiplexer Module
The 60-801-005 is a 6-channel, 5-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.