High Definition TV
Digital broadcast television with higher resoultion than NTSC, SECAM and PAL.
-
Product
Godzilla High Current Probes, 150 Amp
HC500
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
High-Voltage Differential Probe, 100 MHz
N2790A
High Current Probe
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Brute High Current Probe
P4301-2R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
High Frequency Probe
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Digital Wattchman Monitor/Alarm Systems
Model 91091
-
The Coaxial Dynamics 'Digital Wattchman' Rack Mounted Station Monitor/Alarm is similar in function and appearance to our 81090 Series except it is designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM.
-
Product
Brute High Current Probe
P4301-2F
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Cable TV
-
Tempo Communications provides technicians with an array of test and measurement solutions to optimiz... e the installation and performance of broadband cable networks. The tried-and-true TDR from Tempo delivers all of the enhanced features required to pinpoint faults and verify performance. Like all of its test and measurement devices, the focus is on reliability, ease-of-use, and quality—empowering technicians to do their jobs and exceed customer expectations.Show less
-
Product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
High Current Probe
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
High Resistance Measurement Universal Adapter
N1414A
High Resistance Measurement Adapter
N1414A High Resistance Measurement Universal Adapter is used to simplify the connection for high resistance measurements by B2980A series electrometer.
-
Product
PXIe-7903, 28.2 Gbps, 48-Channel PXI High-Speed Serial Instrument
788917-01
High Speed Serial Instrument
The PXIe-7903 is designed for engineers who need high-performance FPGA coprocessing capabilities or who need to validate, interface through, and test serial protocols. It includes a Xilinx Virtex UltraScale+ FPGA to implement various high-speed serial protocols, and it is programmable with the LabVIEW FPGA Module for maximum application-specific customization and reuse. The PXIe-7903 takes advantage of FPGA multigigabit transceivers to deliver 48 TX and RX serial lanes.
-
Product
Wide Angle High Definition Underwater Camera
Surveyor-WAHD
-
The Surveyor-WAHD underwater camera is designed to provide a 14% increase in angle of view, from the previous WAHD camera, whilst remaining compact and very competitively priced. It is ideal for ROV inspection tasks, scientific observation and broadcast applications.Video output is available as component (Y/PbPr), utilising standard connectors or HD-SDI on hybrid 75 Ω coaxial or fibre optic connectors, a composite video output is also available.
-
Product
High Definition MWIR Science-Grade Camera
FLIR X8580™
-
The FLIR X8580 midwave IR camera is designed for scientists and engineers who need to capture detailed imagery of high-speed events, perform custom radiometric measurements, or detect points of failure in composites, solar cells, and electronics. This thermal imaging camera combines 1280 × 1024 HD resolution with fast frame rates and integration times, allowing researchers to record stop motion on fast-moving subjects or rapid temperature changes—whether in the lab or on the test range. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X8580 will provide higher quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
-
Product
Brute High Current Probe
P4301-1Z
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
High Definition Mid-Range Surveillance System
Ranger® HDC MR
-
The Ranger HDC MR sets a new standard for surveillance with its ability to detect illegal activities even in degraded weather conditions, utilizing embedded analytics and image processing to reduce the cognitive workload, enabling operators to distinguish quickly between true threats and false alarms. The HDC MR is not only a superior system in bad weather, it also provides increased uptime and reduces cyber risks -- a reliable tool that adds days of efficient surveillance and reduces risk compared to previous generations of systems.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Digital TV signal analyzer
1750QAM
-
DIGITAL TV SIGNAL ANALYZER 1750QAM? The very excellent signal analyzers of choice for field testing of QAM digital signals on your CABLE-TV SYSTEM.They demodulate and accurately measure the QAM signals carried through the cable system.They provide the measurement power the field technicians need for the latest 64-256QAM digital technologies and are very simple to use, measuring SNR(MER), EVM, Pre-BER, Post-BER, Constellation Diagram.
-
Product
68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable
156166-02
High Speed Digital Cable
The SHC68-C68-RDIO2 is designed and shielded specifically for the digital I/O connector on the USB-7855 and USB-7856 Multifunction Reconfigurable I/O Devices. This cable features digital I/O lines individually twisted with digital ground for high-signal integrity and noise immunity. The SHC68-C68-RDIO2 is available in 1 m and 2 m lengths.
-
Product
Broadcast TV Multiviewer Monitoring System
IMS120
-
The Mividi IMS120 is a broadcast transport stream monitoring system for viewing video and audio services, analyzing transport streams, logging errors, generating alarms, and recording stream. The IMS120 was developed to automate monitoring and error diagnosis at digital head-ends for broadcasters, MSOs, Telcos and online streaming video providers. It is a single Windows based system that can complete tasks previously done by several different pieces of equipment. It will pay for itself in manpower savings over a short period of time.
-
Product
K-50 Series Probes
High Frequency Probe
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
DIGITAL TV LEVEL METER
1500series
-
The optimal signal analyzers to test and measure both analog/digital signals. Especially, these models give users the capacity to measure 'C/N' very easily and correctly, which are very important measurement factors for the TV broadcasting signal.
-
Product
4 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Oscilloscope
WavePro 404HD
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector.MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms.Zone Trigger – Simple Triggering for Complex Signals.
-
Product
6 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Oscilloscope
WavePro 604HD
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events. 15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector. MAUI with OneTouch user interface for intuitive and efficient operation. Deep toolbox enables and simplifies complex analysis. Intuitive navigation to quickly find important features in long waveforms. Zone Trigger – Simple Triggering for Complex Signals.





























