Filter Results By:
Products
Applications
Manufacturers
-
product
FPGA Signal Processor
372
The Model 372 is designed around the Texas Instruments ADS42LB69 16-bit ADC and the Analog Devices AD9788 DAC. The 250 MHz sample clock is supplied by either the on-board frequency synthesizer or an external source. The frequency synthesizer can be phase locked to the local 10 MHz TCXO or an external reference can be used to achieve system-wide phase coherence.
-
product
1.533 Μm Frequency-Locked Laser
Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.
-
product
2 Channels, 28-115 Vrms, 47 Hz-2.5 kHz (max. range) programmable
AC3
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
Hardy Shaker
HI-913
This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.
-
product
Comb Generator, 10 MHz to 50 GHz
U9391F
The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
Comb Generator, 10 MHz To 110 GHz
U9391M
U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
High-Speed Clocking Module
FMC407
Sundance Multiprocessor Technology Ltd.
The FMC407 is a low-noise clock generation and distribution module with eight clock outputs and eight trigger outputs that are fully synchronized. This module can either distribute an externally supplied or a locally generated clock. In the standard configuration, the FMC407 can generate any clock frequency between 34.375 MHZ and 4.4GHz and lock it to an internal or external reference.
-
product
Spectrum Analysis
S95090B
The S95090B spectrum analyzer (SA) measurement software adds high-performance microwave spectrum analysis to PXI VNAs. With fast stepped-FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The S95090B software uses the PXI network analyzer's test and reference receivers to complete simultaneous spectrum measurements. Multi-channel SA measurements leverage the PXI VNA's internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The S95090B spectrum analyzer software application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy. Optional external attenuators should be connected with the VNA’s test ports to avoid receiver compression when measuring large signals.
-
product
3-Ch 200 MHz A/D with DDC & 2-Ch 800 MHz D/A with DUC, Kintex UltraScale - XMC
Model 71821
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Exceptional dynamic range and analog signal integrity- Xilinx® Kintex® UltraScale" FPGA- Three 200 MHz 16-bit A/Ds- Three multiband DDCs (digital downconverters)- One DUC (digital upconverter)- Two 800 MHz 16-bit D/As- 5 GB of 2400 MHz DDR4 SDRAM- Programmable frequency synthesized sample clock generator- Sample clock synchronization to an external system reference- Powerful DMA controllers for moving data- PCI Express (Gen. 1, 2 & 3) interface up to x8- Multi-channel synchronization with clock/sync bus- Optional clock/sync generator for multi-board systems- Optional LVDS port for custom FPGA I/O- Optional gigabit serial links for custom FPGA I/O- Ruggedized and conduction-cooled versions available- Navigator® BSP for software development- Navigator® FDK for custom IP development- SPARK® fully-integrated development system- Free lifetime applications support- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
Intelligent Reference
TM-4D
The Intelligent Reference/TM-4D™ breaks new ground for time and frequency references. For the first time, it is possible to generate and distribute both analog and digital signals to multiple instruments and locations with just one product that fits in a single rack space. The TM-4D is three instruments in one: an Intelligent Reference/TM-4™ precise time and frequency reference, a digital signal distribution amplifier and an analog distribution amplifier. And it eliminates the need for multiple boxes.
-
product
PXI-6608, 5 V, 8-Channel, Precision Reference PXI Counter/Timer Module
777937-01
5 V, 8-Channel, Precision Reference PXI Counter/Timer Module—The PXI-6608 is a high-precision counter/timer module that performs a wide variety of counter/timer tasks, including encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features a 10 MHz oven-controlled crystal oscillator (OCXO), eight counter/timers, digital debouncing filters, and TTL/CMOS-compatible digital I/O. The PXI-6608 offers industrially rugged features for a wide array of applications such as automotive/aerospace, industrial/motion control, and manufacturing test.
-
product
MuClock
Our Muclock is the only commercially available time & frequency reference based on quantum manipulation of laser cooled atoms in the world. This unique solution is the result of more than 15 years of experience acquired by our academic partner, LNE-SYRTE, one of the major international experts in the field of time standards.
-
product
Distribution Amplifiers
A complete range of distribution amplifiers are manufactured by Precision Test Systems. A distribution amplifier is used to distribute the output of a frequency reference to many different places. Usually the frequency is 5 or 10 MHz but we manufacture distribution amps from DC to over 2000 MHz. We make some of the industries lowest phase noise products.
-
product
Hydrophone
RESON TC 4040
The TC4040 is an ideal standard reference hydrophone for calibration of transducers, hydrophones and underwater acoustic measurement systems.The TC4040 offers flat frequency receiving response over a wide frequency range and the relatively high transmitting sensitivity makes it very useful within many areas of underwater acoustic research, tests and measurements.
-
product
Timing Modules
Quartzlock provides Timing Modules for network timing, reference disciplining to various input references such as 1PPS, GPS receiver and Frequency References.
-
product
FMC Module
FMC1831
Sundance Multiprocessor Technology Ltd.
The FMC1831 is an FMC module designed to be compatible with AMC, VPX, PCI, PCIe, CompactPCI and PC/104 carriers. The module has two dual channel AD9361 transceivers with a maximum sampling frequency of 122.8 MHz over a bandwidth of 200 KHz to 56 MHz. A reference clock can be either externally supplied or be generated from an internal PLL. All input and output signals are connected via SSMC connectors for secure connectivity and signal integrity.
-
product
Comb Generator, 10 MHz to 26.5 GHz
U9391C
The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
Multi-Channel Clock Generator
XCLK1
Curtiss-Wright Defense Solutions
High-speed analog IO acquisition systems need a high quality master reference sample clock.Accurate synchronization in the 100MHz and up frequency domains is not easy and it’s a critical performance limiting factor if not done well. The XCLK1 multi-channel clock generator solves these problems.
-
product
Balance Thermocouple Power Sensor, DC To 50 GHz
N8487S
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
product
High Frequency RF and Microwave USB Programmable Signal Generators
LMS Series
The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.
-
product
Comb Generator
CG118
The main application of comb generator is to quickly verify 1GHz above radiated emission and conducted emission test setup.And the most important application is 3m chamber and 10m chamber 1GHz above to18GHz with 250MHz frequency spacing for site validation,shielding efficiency. reference signal source Noise Generators Signal Generators
-
product
10 GHz Signal Source
YIG Series
The SC5503B and SC5502A are designed to meet demanding low phase noise applications. This is accomplished by employing a multiple phase-locked loop architecture as well as a YIG oscillator as the heart of its synthesizer. Frequency accuracy is provided by an onboard 10 MHz temperature compensated crystal oscillator (TCXO) which can be phase locked to an external reference source if required. These modules can be used as standalone CW signal sources or as LO sources for frequency conversion systems such as the SignalCore IQ modulators and demodulators. They are designed to meet the requirements of many modern applications such as wireless device testing, software-defined radio research, point-to-point radio, multi-channel coherent systems, and other academic and military programs.
-
product
Mezzanine System
5174
The 5174 provides two major functions, serving as a precision Voltage Controlled oscillator board and a variable frequency source board. These features can be use together or independently. As a variable frequency source, the 5174 provides a high-resolution variable clock source that is based upon a reference clock supplied by the ECM carrier.
-
product
Spectrum Analysis For E5081A Up To 44 GHz
S960907B
The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
-
product
3-Slot Data Acquisition Mainframe With GPIB, Two 20-Channel Switch Modules, And One 20-Channel Multiplexer Module
DAQ973SB
The DAQ973SB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, two 20-channel DAQM903A Actuator / GP switch modules, and one 20-channel DAQM901A multiplexer module. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junction20-channel actuator / general-purpose switch with independent single-pole, double-throw (SPDT) relaysbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
product
PXIe Vector Signal Generator: 1 MHz to 3 GHz or 6 GHz
M9381A
Choose your RF modulation bandwidth, 40, 100, or 160 MHz, and easily upgrade as test needs change Increase throughput with fastest RF frequency tuning and amplitude switching for high-speed automated test Save space with a compact solution for up to 8x8 MIMO with phase coherence Get up and running quickly with validated application-specific reference solutions Simplify signal creation with Keysight's Signal Studio and Waveform Creator
-
product
RF One Power Meter
The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
-
product
Embedded Local Oscillator Capability
S93084B
The S93084B tunes the network analyzer’s receivers to the output frequency of the converter under test without having to access internal LOs or a common reference signals. For converters with embedded LOs, this enables measurements of match-corrected conversion loss/gain and absolute group delay (requires S93082B and S93083B), gain compression versus frequency (requires S93086B), intermodulation distortion (requires S93087B), and noise figure (requires S93029B).
-
product
Embedded LO Capability
S97084B
The S97084B tunes the analyzer’s receivers to the output frequency of the converter under test without the need for access to internal LOs or a common reference signal
-
product
Frequency Reference
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.