Filter Results By:
Products
Applications
Manufacturers
Patient Simulators
generate known values for any or all of the following medical equipment which measure: invasive blood pressure (IBP), Arrhythmias, Respiration, temperature and Fetal simulation.
-
product
Educational Patient Simulator
EasySim®
The new and improved EasySim® arrhythmia simulator fits in the palm of your hand! The ultra-portable (6.6″ x 2.4″ x .5″), ultra-lightweight (10 oz.) remote control will place you on the leading edge of medical education technology. The highly intuitive design features 48 direct-access keys in a remarkably easy to use format. No codes to memorize! No fuss to set up!
-
product
Patient Simulators
Patient Simulators - also known as physiological simulators are essential tools for biomedical personals to accurately test and verify the performance of patient monitoring systems such as cardiac monitors, ECG machines. It simulates physiological parameters such as ECG, arrhythmia waveforms, blood pressure, respiration, temperature.
-
product
Patient Simulator
PatSim200
Designed to make every patient simulation, quicker. Unlike other Patient Simulators, the PatSim uses a home and recall function to easily move between tests and store your most used sequences, no more clicking and scrolling through ‘tree style’ hierarchy to perform each test. Functions: 12 lead NSR ECG simulation, Over 40 selectable Arrhythmias, Performance waveforms, Respiration simulation on lead I & II, Universal temperature simulation, Two channel IBP simulation and Fetal simulation.
-
product
Multi-Parameter ECG Patient Simulator
SL-8 SimSlim®
The smallest, comprehensive multi-parameter patient simulator on the market. Includes ECG, Respiration, Arrhythmia, 4-IBP, YSI 400/700 Temperature, and Cardiac Output. Its patented power circuitry provides amazing battery life up to 10 years without charging or changing batteries! One button operation reduces the time for setup and completing testing. View the product manual on our User Manuals page.
-
product
Patient Simulators
Patient simulator enables you to complete preventive maintenance testing with one device in less than five minutes, reducing average test time by up to 88 %. The ProSim 8 patient simulator is also ideal for design engineers looking for a known physiological signal output.
-
product
PXI RTD Simulator Module, 20 Channel, PT500
40-263-102
The 40-263-102 is a 20-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
43-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal.
-
product
PXI Battery Simulator Module
41-750-001
The 41-750 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for PCI With 2 Or 4 CAN Bus Nodes
ACP825-x
ARINC825 (CAN bus) Test & Simulation module for PCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825-x PCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
PXI Battery Simulator 2.8 Amps
41-753-001
The 41-753 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals that can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
4, 8, 16, 32 Channel ARINC429 Test And Simulation Module For PCI
APXX429-x
ARINC429 Test and Simulation bus interface with 4, 8, 16 or 32 Software programmable Tx/Rx channels plus up to 8 Discrete I/O’s.
-
product
PXI Battery Simulator Module
41-751-001
The 41-751 is a low power battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
Single, Dual Or Quad Stream MIL-STD-1553A/BTest And Simulation Module For PCI
APXX1553-x
MIL-STD-1553 Test and Simulation Module for PCI with 1, 2 or 4 Dual Redundant channels (APXX1553-1, APXX1553-2, APXX1553-4) plus 8 programmable discrete Input/Output channels. A unique feature of AIM’s APXX1553-x module is the option for the MILScope™ capability. Models APXX1553-1-DS/APXX1553-2-DS integrate an onboard Analogue to Digital Converter (ADC) which samples, measures and stores the MIL-STD-1553 waveform. Automatic waveform validation is performed by the users Application Software or in conjunction with AIM’s PBA.pro Databus Test and Analysis Software and Test Scripts.
-
product
4, 8, 16 And 32 ChannelARINC429 Test And Simulation Modulefor PCI Express
APE429-x
ARINC429 Test and Simulation modules with 4, 8, 16 or 32 Software programmable Tx/Rx channels plus up to 8 Discrete I/O’s. The APE429-x is a functional replacement for the models API429-x/APX429-x.
-
product
PXI RTD Simulator Module, 8 Channel, PT500
40-263-402
The 40-263-402 is an 8-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 18 Channel PT100
40-262-001
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
product
P104 Synchro/Resolver Simulation Board
73DS2
NAI’s 73DS2 is a PC104-compatible Synchro/Resolver Simulation Board with three isolated channels. These channels can incorporate up to three Digital-to-Synchro/Resolver Converters with 1.2 VA drive capability in a stack-through module. With galvanic isolation, one of the outputs can be grounded without affecting performance.
-
product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
4, 8, 16 And 32 Channels ARINC429 Test & Simulation Module CompactPCI/PXI (3U)
ACXX429-3U-x
The ACXX429-3U-x is a functional replacement formodel ACX429-3U-x.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
product
Regenerative Grid Simulator
61800 series
Market demand for Distributed Resource (DR) products such as PV inverters and wind energy systems is steadily growing as the world strives for clean renewable energy sources. This demand has created a need for rigorous regulation testing to standards such IEEE 1547 / IEC 61000-3-15 / IEC 62116 ensuring proper and safe operation of on-grid products. It has become critical to manufacturers to conduct these tests to prove compliance and to relieve product liability concerns. Chroma’s new 61800 family of Grid Simulators has been designed to fulfill these test requirements by providing a full 4 quadrant, fully regenerative, grid simulator with advanced features for compliance, safety and product verification testing.
-
product
Configure Battery Pack Simulator for Battery Management System (BMS) Hardware-in-the-Loop (HIL) Testing
Customized configuration for battery pack simulator by Bloomy
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module
41-670-XYZ-AABBCC
The 41/43-670 range is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. Available with up to four banks, each bank is capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
41-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
Solar Array Simulator
62000H-S series
The latest programmable solar array simulator power supply 62000H-S Series released by Chroma provide simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000H-S provides an industry leading power density in a small 3U high package. The solar array simulator is highly stable and has a fast transient response design, which are both advantageous to MPPT performance evaluation on PV inverter devices. The 62000H-S Series have many unique advantages including high speed & precision digitizing measurement circuits with a 100kHz A/D, 25kHz D/A controlled I-V curve and a digital filter mechanism. It can simulate an I-V curve accurately and response the mains ripple effect from the PV inverter. In addition, the built-in EN50530/Sandia SAS I-V model in the standalone unit can easily program the Voc, Isc, Vmp, and Imp parameters for I-V curve simulation, without a PC controller.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for PCIe
ACPe825-x
ARINC825 (CAN bus) Test & Simulation module for PCIe with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825 PCIe card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.