Oscilloscope Calibrators
-
product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
product
Resistor Calibration Boxes
RCB-3
Standard Electric Works Co., Ltd
● The RCB-3 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
-
product
Resistor Calibration Boxes
RCB-1
Standard Electric Works Co., Ltd
● The RCB-1 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
-
product
Multifunction Voltage and Current Calibrator
MC140i
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
product
Relative Humidity Calibration Services
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
product
Calibration Modules and Kits
Keysight Calibration Modules achieve more precise and accurate measurements for your testing needs. Regular calibration is required to ensure your high-performance measurement equipment is operating to its specified performance, and our Calibration Modules and Kits make the calibration of your equipment fast, easy, and accurate.
-
product
Vibration Calibrators
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra is a leading manufacturer of vibration sources for the calibration of accelerometers, velocity and displacement sensors. Metra's vibration calibrators have some unique features such as a very high payload and variable vibration frequencies.
-
product
Ice Point Calibrators
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
product
Pressure Calibrator
30
AMETEK Sensors, Test & Calibration
The 30 Series is a wide range digital pressure calibrator that fits easily into your shirt pocket. Its internal sensors give you 0.05% of reading accuracy and resist damage from overpressure.
-
product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
product
Acoustic Calibrators
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
product
Calibration Kit
F7511
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
product
Digital Load Calibrator
HS 2000
Jinan Testing Equipment IE Corporation
The load cell calibrator is used to calibrate the load of testing machine and hardness tester, and also can be used for force measuring. It is digital display type with high accuracy of less than +0.3%, and easy to operate
-
product
Oscilloscope & Data Recorder
DL350 ScopeCorder
A ScopeCorder combines the transient signal capturing capabilities of an oscilloscope with the long-term datalogging capabilities of a data recorder. For “quick and easy” troubleshooting or sophisticated mixed-signal datalogging, the DL350 is a portable, powerful, and usable engineering tool that makes complete measurements completely portable.
-
product
SP200B, 200 MHz, ±60 V, 1X or 10X Attenuation, Single-Ended Passive Oscilloscope Probe
780284-01
The SP200B is a standard switchable passive probe for oscilloscopes that provide 1 MΩ input impedance. Depending on the attenuation ratio, the probe has an analog bandwidth of 6 MHz in the 1x attenuation setting or 200 MHz in the 10x attenuation setting.
-
product
Oscilloscopes
Berkeley Nucleonics Corporation
Is a type of electronic test instrument that graphically displays varying voltages of one or more signals as a function of time. Their main purpose is capturing information on electrical signals for debugging, analysis, or characterization.
-
product
Oscilloscopes
PicoScope 9000 Series
Up to 25 GHz bandwidth9.5 GHz optical input40 ps Differential TDR / TDT sourceSequential sampling Oscilloscope
-
product
Auto Calibration for Load & Extensiometer
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
product
Hand-helds, Calibrators
Hand-helds pressure indicators are portable calibration instruments for mobile use for the accurate measurement and recording of pressure profiles. There are interchangeable pressure sensors with measuring ranges of up to 8,000 bar available for the instruments. Through this, hand-held indicators, and multifunction calibrators, are particularly suitable as test instruments for a large variety of applications in the widest range of industries.
-
product
UV/VIS/NIR Spectrophotometer Calibration Standards
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
product
Crossover Calibrator
CC-1
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
product
Torque Calibration
Calibration capabilities for torque applications range from 15 inch-ounces to 2,000 foot-pounds with electronically converted readings in every common unit of measure. NIST traceable weights and torsion arms provide traceability on all Process Instruments'' Torque Calibrations. Force gauges and torque transducers can also be calibrated with this system.
-
product
Calibration Services
WTG's calibration package is more than just verification of performance specs. It is a complete package of services including inspection and maintenance. Our services uphold the value of the instrument and extend its lifetime.
-
product
Calibration
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
product
4 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Oscilloscope
WavePro 404HD
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s.Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector.MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms.Zone Trigger – Simple Triggering for Complex Signals.
-
product
Liquid Calibration Baths
Designed for calibration of temperature control devices that contain hazardous or corrosive fluids. Meets Class 1, Division 1 requirements for operation in a hazardous environment. CSZ explosion proof liquid calibration baths are designed to calibrate a large number of temperature sensors which contain a variety of different types of hazardous fluids. The sensors are typically calibrated in the same fluid used in the sensing element of the control devices per specification.
-
product
FlexRes® Oscilloscopes
PicoScope® 5000 Series
High speed and high resolution. Breakthrough ADC technology switches from 8 to 16 bits in the same oscilloscope.
-
product
PAT Calibration Checkboxes
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
product
PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope
778756-02
100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.