Resistivity
the amount which keeps current from flowing freely.
See Also: Resistance, Resistance Standards, Resistance Meters, Resistance Test, Resistivity Meters, Current, Polarization
-
Product
Thick Film Divider
GBR-391
-
GBR-391 series high-voltage resistive dividers are made in a thick film technology on ceramic substrates (Al2O3 - 96%) with leads for through-hole mounting. Dividers are characterized by very high maximum voltage, and standard voltage division.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20J
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
High Precision Digital 10A Mirco-Ohmmeter
DRM-10A™
-
The DRM-10A™ is a lightweight and portable micro-ohmmeter designed to measure very low resistances from 0.01 μΩ to 200 Ω. It is the most accurate in its category.
-
Product
Handheld Clamp Meter, 3 ½ Digit
U1213A
Digital Multimeter
Handle large currents up to 1000 A safely with 2-inch large jaw opening. Wider range DCV, ACV and resistance. Keysight Remote Link Solution allows datalogging wirelessly via Bluetooth.
-
Product
Syscal Kid
-
Specifically designed for very shallow, high resolution resistivity and induced polarization sounding and profiling, the Kid is the most compactof the Syscal range whilst retaining the well-known reliability and measurement accuracy of its counter parts.
-
Product
AC/DC Digital Clamp Tester (CE)
M-260
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
Product
Multimeter
МЦММ1
-
The mezzanine module (mezzanine) МЦММ1 is designed to measure AC and DC voltage, AC and DC current, DC resistance and frequency of a periodic signal.
-
Product
Incline Impact Tester
KRD100 series
-
KRD100 series incline impact tester simulates the ability of product packaging to resist shock damage in the actual environment, such as handling, stacking of shelves, sliding of motors, loading and unloading of locomotives, product transportation, etc. This machine can also be used as a common test equipment for scientific research institutions, colleges and universities, packaging technology test centers, packaging materials manufacturing plants, and foreign trade, transportation and other departments to conduct incline impact test.
-
Product
High 0.75 (21.00) - 8.00 (227.00) Long Travel Bead Probe
BPLT-25F-8
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Test System
ITC57300
-
The ITC57300 Dynamic Parametric Test System mainframe accepts Test Heads that perform nondestructive transient measurements on semiconductor devices such as Insulated Gate Bipolar Transistors (IGBT), power MOSFETs, diodes, and other bipolar devices(requires additional optional bias power supplies and custom personality boards). Included in the mainframe are all test equipment and software necessary to analyze and perform resistive and inductive switching time, switching losses, gate charge, Trr/Qrr, and other transient tests.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Load Bank
-
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
Product
Mini Power, Contact, ITA, 65 Amp, 8 AWG
610115124
Power Contact (ITA)
Primary mating contact 610116112. (May mate with other Receiver contacts, as well.)Mini Power contacts carry up to 65 amps continuous current, 480 VAC. Maximum resistance is 1 Milliohms.Specifications Operating Voltage & Current 65 Amps Max. Continuous – 8 AWG40 Amp Max. Continuous – 12 AWG30 Amp Max. Continuous – 14 AWG25 Amp Max. Continuous – 16 AWGContact Resistance 1 mOhms Max.Dielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 1000 MOhms Min.Contact Body BeCuContact Plating 50µ" Au over 100µ" NiContact Termination SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 3.37
-
Product
Precision Capacitance Meter
TH2638B
-
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Electrical Standards
-
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
Product
PXI 10W Programmable Resistor Module, 2-Channel, 1Ω to 470Ω
40-253-014
Programmable Resistor Module
The 40-253-014 is a programmable resistor module with 2 channels which can be set between 1Ω and 470Ω with 2Ω resolution The 40-253 range provides a simple solution for applications requiring up to 10W of power handling per channel. The 40-253 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Product
Clamp Meters
-
Omega Clamp Meters provide True RMS Current and Voltage measurements and also include additional measurements typically found in Multimeters such as AC/DC voltage, current, resistance and others.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-9
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Single 16x16 1-Pole High-Density PXI Matrix Module
40-520-001
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI Dual 16x8 Matrix, 1 Pole Switching
40-532-021
Matrix Switch Module
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
Limit Switches
-
With its choice of casings, wide range of actuators, variety of connections and high degree of resistance to impact and splashes, Crouzet Switches offers limit switches available in the following ranges: Metal body, Plastic body, Special products and Products for severe environments. Their main characteristics are: IP6x seal, a wide range of actuators (plungers and rollers), rotary heads with momentary action, positive break contacts, compact size, etc. They also offer the option of having special levers, prewiring, connection via ISO cable glands, etc.
-
Product
Circuit Breaker Test Equipment
-
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
Product
Cryogenic Temperature Sensors
Ultra-low temperature Rox™
-
With the amazing progress made by dilution refrigerator manufacturers to push base temperatures well below 10 mK, the need for accurate, simplified temperature measurements continues to grow. The RX-102B-RS meets this need as a resistive temperature device (RTD) that maintains sensitivity well below 10 mK.
-
Product
PXI 2.5W Programmable Resistor Module, 4-Channel, 1.5Ω to 1.81kΩ
40-251-022
Programmable Resistor Module
The 40-251-022 is a programmable resistor module with 4 channels which can be set between 1.5Ω and 1.81kΩ with 0.5Ω resolution The 40-251 range provides a simple solution for applications requiring up to 2.5W of power handling per channel. The 40-251 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-W
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
L Terminal Shunt Resistor
LT
-
LT shunts are highly accurate manganin resistance D.C. shunts. These shunts are designed for standard current measurement of electric equipment.