Fiber Fault Locators
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
42-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
product
LXI Single 32 Channel Fiber Multiplexer FC/APC, Single-Mode With Loop-Thru
60-850-024
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
Optical Fiber Fusion Splicer
SH-FS180H
Shenzhen Sharingtek Communication Co., LTD
This equipment takes advanced PAS technology, can be used for different fiber projects.9s quick splicing5000 sets of the latest record storage4800mAh large capacity lithium battery400X magnification
-
product
MM Fiber Test
KI-TK032
850/1300 nm source & power meter, inspection microscope, cleaning materials. Interchangeable SC & LC connectors
-
product
High-Speed Multipoint Fiber Optic Sensing
HYPERION
Luna’s HYPERION platform delivers reliable and high-performance measurement and monitoring solutions. Utilizing sensors based on Fiber Bragg Grating (FBG) or Fabry-Perot (FP) sensors, Luna’s HYPERION systems have been deployed in hundreds of challenging applications all over the world, delivering reliable, long-term monitoring with dense sensor installations.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber, ST Connectors
42-852A-518
The 40/42-852A-518 is a PXI/PXIe 8-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
NI-9861, 1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module
781962-01
1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module—The NI‑9861 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The NI‑9861 is ideal for applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. You can perform this manipulation while taking other data acquisition measurements in the same NI CompactDAQ hardware platform or while performing low-level FPGA control and embedded monitoring in the same NI CompactRIO chassis.
-
product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Single-Mode, 9/125 Fiber
40-855A-112-HI
The 40/42-855A-112-HI is a PXI/PXIe 2-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
Short Circuit Locator for Power Cables
A910
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
product
Fiber Optical Switch at Single Mode Latching 1310/1550nm 5V with LC/PC Connector
SUN-FSW-1x2H
Guilin GLsun Science and Tech Group Co., LTD
GLSUN 1×2H Mechanical Optical Switch Fiber Switch Features·Low Insertion Loss·Wide Wavelength Range·Low Crosstalk·High Stability, High Reliability·Epoxy-free on Optical Path·Latching and Non-latchingGLSUN 1×2H Mechanical Optical Switch Fiber Switch Applications·R&D in Laboratory·System Monitoring·OADM·MAN (Metropolitan Area Network)·Network Security and MonitoringGLSUN 1×2H Mechanical Optical Switch Fiber Switch SpecificationsParameters Unit SUN-FSW-1×2HWavelength Range nm 1260 ~ 1650Test Wavelength nm 1310 / 1550Insertion Loss 1, 2 dB Typ: 0.8 Max: 1.0Return Loss 1, 2 dB SM ≥ 50Crosstalk 1 dB SM ≥ 55PDL dB ≤0.05WDL dB ≤0.25Repeatability dB ≤±0.02Operating Voltage V 3.0 or 5.0Durability Cycles ≥ 10 MillionSwitching Time ms ≤8Optical Power mW ≤500Operating Temperature ℃ -20 ~ +70Storage Temperature ℃ -40 ~ +85Relative Humidity % 5 ~ 95Weight g 14Dimension mm (L )22.5×(W)11.8×(H)10.2 ±0.2Note: 1 Within operating temperature and SOP.2 Excluding Connectors.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors
42-850A-114-M62.5
The 40/42-850A-114-M62.5 is a PXI/PXIe 4-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI Dual 2 Channel Fiber MUX ST
40-855-522-M
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
Fiber Optic Sensing Instrument
RTS125+
The fully ruggedized RTS125+ fiber optic sensing instrument was created in partnership with NASA to support the test and validation of their new vehicles. It delivers the most reliable measurements for structural testing, design optimization, structural health monitoring, thermal mapping and 2D shape sensing.
-
product
Fiber light source
UV irradiation UV curing, infrared irradiation Thermal curing is possible with one unit. All-round player suitable for R & D · mass production line
-
product
Fiber Optical Cable Testers
Encompasses the processes, tools, and standards used to test fiber optic components, fiber links, and deployed fiber networks.
-
product
Fiber Optic Sensors And Amplifiers
Omron’s high-performance fiber optic sensors and amplifiers come in a wide variety of configurations to meet your specialized requirements.
-
product
The Nortech Fiber Optic Monitors
The fiber optic signal conditioners are designed for direct, accurate and real-time temperature monitoring to manage and maximize your transformer’s performance. The Nortech temperature monitor family comes in three different classes: the EasyGrid is the most comprehensive model, the EasyGrid LT is a compact and very cost-effective model for low channel count monitoring applications, and the EasyGrid Base is and even more compact model designed for easy network integration.
-
product
Optical Fiber Identifier
X5004
Lower power indicationEasy-to-replace adaptersEasy-to-use with "ONE KEY" operationDisplays the relative core powerDurable metal housing and quality constructionEfficiently identifies the fiber transmission direction and frequency tone (270Hz, 1 KHz, 2 KHz) with audible warning
-
product
Pipe & Cable Locator
505
Split box locator, Inductive Operation, Conductive Operation, Locate Unknown Pipes, Peak Method, Null Method, Very Accurate Depth Location.
-
product
Entry-level Price Interferometer for Geometry Measurement of Single Fibers
3D SCOPE-V2
Specifically designed for use in a production environment, 3D Scope-V2 is a robust, compact and easy to use interferometer that brings speed and precision to operators. 3D Scope-V2 supports our Blink software platform. Non-compressed, real time and high quality images are transfered from the hardware to the software via a USB 2.0 link in addition to the automation and control commands.
-
product
Cable Fault Locator System
Kvtester Electronics Technology Co.,Ltd
To test the HV arcing fault of cable, earthing high &low resistance, short circuit and breakage of the cable, poor contact, etc. If equipped with fault locator, it can decide the exact broken position of the cable ,applies to power cable in various type, voltage and communication cable
-
product
Optical Fiber Cable Testing Equipment
Optical fiber consists of a core and a cladding layer, selected for total internal reflection due to the difference in the refractive index between the two. In practical fibers, the cladding is usually coated with a layer of acrylate polymer or polyimide. This coating protects the fiber from damage but does not contribute to its optical waveguide properties. Individual coated fibers then have a tough resin buffer layer and/or core tube(s) extruded around them to form the cable core. Several layers of protective sheathing, depending on the application, are added to form the cable. Rigid fiber assemblies sometimes put light-absorbing ("dark") glass between the fibers, to prevent light that leaks out of one fiber from entering another. This reduces cross-talk between the fibers, or reduces flare in fiber bundle imaging applications Optical fibers are very strong, but the strength is drastically reduced by unavoidable microscopic surface flaws inherent in the manufacturing process. The initial fiber strength, as well as its change with time, must be considered relative to the stress imposed on the fiber during handling, cabling, and installation for a given set of environmental conditions. There are three basic scenarios that can lead to strength degradation and failure by inducing flaw growth: dynamic fatigue, static fatigues, and zero-stress aging.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber, FC/APC Connectors, With Interlock
42-850A-014-M50-HI
The 40/42-850A-014-M50-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass, Single-Mode, 9/125 Fiber, SC/PC Connectors
42-860A-222
The 40/42-860A-222 is a PXI/PXIe dual insert/bypass switch with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
Fiber Patch Cables
Wuhan Sunma Technology Co., Ltd.
SunmaFiber Patchcord and Pigtails is suitable for enterprise network, telecom room, server farms, cloud storage networks, and any place fiber jumper cables or pigtails are needed. It meets RoHS compliant, and cable is optically tested for insertion loss to ensure high quality.SunmaFiber supply fiber optic patch cord, fiber optic patch cable,LC,SC/APC,ST,E2000/APC,MU,VF45,FC, MT-RJ, SC, MPO, Volition, MTP, FC/APC, ST/APC, LC/APC, E2000, DIN, D4, SMA, Escon, FDDI, RoHS compliant, LSZH, Riser, Plenum, OFNR, OFNP, simplex, duplex, single mode, 9/125, SM, multimode, MM, 50/125, 62.5/125.
-
product
Cable Fault Locator
HT-TC / 400
Wuhan Huatian Electric Power Automation Co., Ltd.
Important test tools for wireline communication and power transmission line maintenance.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, FC/APC Connectors, With Interlock
42-850A-014-M62.5-HI
The 40/42-850A-014-M62.5-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, Single Ended
7-413845000-036
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, Single Ended.





























