Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-708
-
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
40-788-021-T
-
The 40-788-021-T (PXI) and 42-788-021-T (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
VLF Testing and Diagnostics Unit
Viola TD
-
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated, 3GHz, 50Ω, MCX
42-873A-002
-
The 40-873A-102 (PXI) and 42-873A-102 (PXIe) are 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-785C-443-E
-
The 40-785C-443-E (PXI) and 42-785C-443-E (PXIe) are triple failsafe SP4T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 26.5GHz, 50Ω, SMA, Terminated, Remote Mount
40-785C-432-TE
-
The 40-785C-432-TE (PXI) and 42-785C-432-TE (PXIe) are dual SP4T 26.5GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI-4130, ±20 V, ±2 A DC, 40 W PXI Source Measure Unit
779647-31
-
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
Product
Dual 16 to 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-765A-002
-
The 40-765A-002 terminated dual 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 50 GHz, 50 Ω, SMA-2.4, Remote Mount, Failsafe
42-780B-551-E
-
The 40-780B-551-E (PXI) and 42-780B-551-E (PXIe) are single failsafe SPDT 50 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
Single 8 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-763-001
-
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 3 GHz, 50 Ω, N-Type, Terminated, Remote Mount, Failsafe
42-785C-562-TE
-
The 40-785C-562-TE (PXI) and 42-785C-562-TE (PXIe) are dual failsafe SP6T 3 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Remote Sensor Airborne Particle Counter
CI-3100 Trident Series
-
Remote Sensor Airborne Particle Counter1 CFM With Internal Vacuum Pump For Continuous Monitoring. Long-Term Accuracy & Unsurpassed Repeatability of Measurement. 10,080 Sample Data Buffer.
-
Product
Inertial Measurement Units
IMU
-
The Inertial Labs Inertial Measurement Units (IMU) contain three highly accurate advanced MEMS gyroscopes and three high-performance accelerometers. The IMU-P and Kernel are calibrated within their operating temperature range to achieve maximum end-user usability. This also ensures tactical grade performance regardless of the environment in which it is used.
-
Product
PXI/PXIe RF Switch, Hex SPDT, Terminated, 8GHz, 50Ω, SMA
42-880B-003
-
The 40-880B-003 (PXI) and 42-880B-003 (PXIe) are hex SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range have automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in slots or hex and octal switches in three slots.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 8 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-788-011-E
-
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40 GHz, 50 Ω, SMA-2.9, Terminated, Failsafe
42-785C-441-T
-
The 40-785C-441-T (PXI) and 42-785C-441-T (PXIe) are single failsafe SP4T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Relay, Dual SPDT, 18GHz, 50Ω, SMA, Internal Termination
40-781A-022
-
The 40-781A-022 (PXI) and 42-781A-022 (PXIe) are dual SPDT 18GHz microwave relay modules with internal terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50GHz in 50Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 22 GHz, 50 Ω, SMA, Terminated, Failsafe
40-788-131-T
-
The 40-788-131-T (PXI) and 42-788-131-T (PXIe) are single failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-785C-523-E
-
The 40-785C-523-E (PXI) and 42-785C-523-E (PXIe) are triple failsafe SP6T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Multifunction Switch / Measure Unit, Modules
34980A Series
-
The Keysight 34980A multifunction switch / measure mainframe and modules provide functionality that is easy to set up and use. The 34980A helps you lower your cost of test and accelerate your test system integration and development.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 50GHz, 50Ω, SMA-2.4, External Termination
40-781A-721
-
The 40-781A-721 (PXI) and 42-781A-721 (PXIe) are single SPDT 50GHz microwave relay modules with external terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50GHz in 50Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
Remote Cable Tester for RJ45 RJ11 USB and BNC
REMOTETEST
-
Troubleshoot your wiring problems, quickly and affordably with StarTech.com's REMOTETEST, a Specially designed network wire tester that saves valuable time and effort when testing RJ45, RJ11 and BNC cables.
-
Product
Remote Ethernet Modbus TCP I/O Modules
-
ET-7000 Modbus TCP Remote Ethernet I/O allow configuration, I/O monitoring and control through a regular web browser. Besides Web HMI function, no more programming or HTML skills are required; creating dynamic and attractive web pages for I/O monitoring. They can be easily integrated with SCADA software and other I/O. They come with EZ Data Logger Software for data logging and monitoring systems.
-
Product
ABex Terminal Module for JTAG Technologies JT 37x7 BSCAN Cards
ABex TM-JT37x7
-
The ABex TM-JT37x7 is an ABex terminal module for the JTAG Technologies Boundary Scan Controller PXI/PXIe JT 37×7. In combination with the JT 2147/ABex from JTAG Technologies it integrates the POD functionality into the module.In combination with the PXI/PXIe JT 37×7 and the JT 2147/ABex it’s possible to connect up to four JTAG/Boundary Scan TAPs. All signal wires on the PCB are impedance controlled. In addition, all signals can be switched off via relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Remote Mount
42-788-051-E
-
The 40-788-051-E (PXI) and 42-788-051-E (PXIe) are single SP8T 40 GHz unterminated microwave multiplexers with remotely mounted relays.
-
Product
PXI/PXIe Microwave Relay, Dual SPDT, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-780B-532-E
-
The 40-780B-532-E (PXI) and 42-780B-532-E (PXIe) are dual failsafe SPDT 26.5 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
PCIe Basic Protocol Multi Terminal Emulation
Sy629PCIe-BPT
-
The Sy629PCIe-BPT card provides a convenient means for transmitting and receiving data over an ARINC 629 bus in accordance with the transmit and receive programme defined by data written into the XPP and RPP memory. In particular, this product can emulate up to 120 terminals transmitting on an ARINC-629 data bus whilst correctly maintaining the approved Basic Protocol.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount
42-782B-551-E
-
The 40-782B-551-E (PXI) and 42-782B-551-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-785C-471-E
-
The 40-785C-471-E (PXI) and 42-785C-471-E (PXIe) are single failsafe SP4T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.