Resistance Meters
measure opposition to electrical current.
See Also: Resistance, Resistivity, Resistance Standards, Resistance Test, Resistivity Meters
-
Product
Transformer Winding Resistance Meters
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Circuit Breaker Contact Resistance Meters
-
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
Product
Insulation Resistance Meters
-
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meterAnalog indicator, High measurement speedTest voltage range: 10 V to 500 VSuitable for Test capacitor insulation testEasy operation
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Resistance Meter - Portable, Precision Resistance Measurement from 0.10 to 1.00 x 10^12 Ohms
PRS-812B
-
- Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 120 Data Set Internal Memory- Uses Standard USB Cable for Charging- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument
-
Product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
-
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Resistance Meter
MT8-4L
-
М-module МТ8-4Л is a mezzanine module designed to measure the resistance of resistive sensors using a four-wire measurement circuit in eight channels (eight-channel digitizer). М-module МТ8-4Л is installed on the carrier of mezzanines - module НМ-М and is connected to it via a local information highway. Up to four m-modules of various types can be installed on the NM-M module. The NM-M module, together with the m-modules installed on it, forms a VXI module of size C-1 and is used to create information measuring VXI systems.
-
Product
Ohm-Stat Ground/Circuit Tester to Test ESD Ground
-
Tests ground for all 110v electrical circuitsWill determine the status of all electrical groundsEasy to use LED lightsWarranteeProduct conforms to the ESD S.20.20 spec standardsIdentify electrical problemsUsed with the Ohm-Stat RT-1000 resistivity meter
-
Product
Syscal R1 Plus Switch
-
The SYSCAL R1 Plus resistivity meter is specifically designed for medium-depth exploration. It combines a power source, transmitter up to a 200W or 1200Vpp output voltage, and a 2 channels receiver in a single unit; its compactness makes it an effective tool for intensive resistivity surveys.
-
Product
Highly Inductive Resistance Meter
MR 8050
-
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
Product
Insulation Resistance Meter
SME1202
-
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meter Analog indicator, High measurement speed Test voltage range: 10 V to 1000 V Suitable for Testing capacitor insulation test Easy operation
-
Product
Syscal R1 Plus
-
The SYSCAL R1 Plus resistivity meter is specifically designed for medium-depth exploration. It combines a power source, transmitter up to a 200W or 800Vpp output voltage, and a 2 channels receiver in a single unit; its compactness makes it an effective tool for intensive resistivity surveys.
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
Insulation Resistance Meter
-
Changzhou Applent Instruments Inc.
Designed for measuring very high resistance and related parameters of insulation materials, electronic components, and electro-mechanical components.
-
Product
Resistance System Kit
PMK-151
-
The PMK-151 Basic Measurement Kit has all the functionality of the PMK-152, but adds computer downloading capabilities. It contains all the instruments you need to take a variety of resistance measurements.The PMK-151 includes Prostat's PRS-801 Resistance Set with modified 5 pound conductive rubber electrodes, the PRS-801 wide range resistance meter, and Prostat PRS-801 Connectivity software for computer data downloading. You can take measurements at 10 and 100 volts with accuracy within ±5%.
-
Product
Winding Resistance Meter
TRM 25
-
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Winding Resistance Meter
-
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
Product
Resistance System - Digital Surface Resistance Meter up to 200 TeraOhms
PRS-801B
-
- Accurate Wide Range Resistance Measurements: 0.01 Ω to 2.00x1014 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Variable Voltage 0.1 mv to 9.99 V for low resistance measurements- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 999 Data Set Memory- Download to Excel® in Batches or Individual Measurements with Prostat Connect 2.0- Uses Micro USB Cable for Charging and Downloading Data- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument
-
Product
Winding Resistance Meter 50Amps, 3 Channels Rack
WR50-13R
-
Raytech Digital Winding Resistance meter WR50-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)
HE-200R
-
HE-200R connects resistivity sensor (ERF Series) and measures resistivity and temperature in the sample water. It is suitable for measurement of UPW resistivity.
-
Product
5kV Insulation Resistance Tester
KV3122
-
KV Hipot Power Test Equipment Co.,Ltd
KV3122 Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit.
-
Product
Automatic Transformer Observation System
ATOS
-
Raytech – The World leader in design and manufacturing of high-quality precision measuring instruments and systems, offering flexibility and versatility. Our modular Automatic Transformer Observation System (ATOS) allow you to create a unique and custom solution for any application. ATOS is designed to drastically reduce measuring time and increase test performance, without losing accuracy compared to individual test instruments. With the choice of up to three Multiplexers (primary, secondary, and tertiary), three Winding Resistance Meters, each with three maximum current range options (up to 15A, 50A, or 100A), Turns Ratio, and Integrated power security and safety panel (ISU R), Raytech can create a system with your needs and budget in mind.
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
Product
Surface Resistivity Meter
395
-
The ACL 395 handheld meter features sophisticated circuitry that allows for the same advantages as megohmmeters, but at an economical price. Utilizing color-coded zones, the LED scale is easy to read and evaluate. Half decades indicate where the measurement value falls within the decade giving a closer indication to actual value. Unlike other pocket-sized meters, the ACL 395 features rubber rails which provide the best possible contact.