Voltage Converters
Changes the voltage of a source.
-
product
Connect PT100/PT1000 Sensors To Output A Voltage Signal
K- PT100/1000
Our K-PT module is designed to connect up to PT100/PT1000 sensors and simply provides an output voltage signal. Thus enabling the most standard voltage measurement devices to work with PT100/PT1000 sensors. The PT100 sensors offer excellent accuracy and repeatability.
-
product
Precision Voltage and Current Sources
VI-700
The VI-700 Voltage and Current Source is a versatile precision dialable or remotely programmable voltage and current source. Its three ranges provide up to 20 V full scale (200 V with the HV option), and down to 100 mV resolution; and 20 mA full scale down to 0.1mA resolution. Both voltage and current outputs are available simultaneously. The output is set by a range selector and thumbwheel switches in the LOCAL mode, or by a digital input at the rear panel. The REMOTE mode control can be a RS232 or IEEE-488 interface.
-
product
High Voltage Instrumentation
For applications requiring high voltage isolation, Encore Electronics offers a line of DIN rail mounted instruments.
-
product
2kV, 400 MHz High Voltage Differential Probe
HVD3220
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Screwdriver Probe Voltage Tester
SD-328H
Easy and safeTests AC/DC voltage from 110-250VHandy pocket screwdriver is a fully functional voltage testerInsulated screwdriver shaftConvenient screwdriver tip and pocket clip
-
product
Analog-to-Digital Converter (A/D) and Counter-Timer Card
AD8-16 (ADA-8)
Model AD8-16 (alternate part number ADA-8) is an economical, multiplexed, eight-bit Analog-to-Digital Converter (A/D) and Counter-Timer card for ISA-bus computers. It accepts up to eight differential or 16 single-ended analog inputs (jumper configured). AD8-16 requires a full-size expansion slot. All connections are made through a standard 50-pin connector. Base I/O address selection is via dip switch.Analog inputs are multiplexed, amplified, held by a sample and hold amplifier, and then digitized by an eight-bit A/D converter. Amplifier gain is selected by software and can differ from channel to channel.
-
product
Frequency Converter Upwards
UPCONVERTER 10 GHz VXI
The UPCONVERTER 10 GHz control software is VXI Plug & Play and does not depend on the module version. The software allows for automated calibration and verification of the main characteristics of the device.
-
product
Analog to Digital Converter
7418/7419
Supports thermocouples, RTD's, strain gauges, voltage in, 4-20 mA, thermistors, and resistorsUp to 16 differential input channels plus sensor excitationEach channel is software programmable for sensor type, gain, low-pass filtering, scan rateAuto-calibration eliminates trimpotsLow power consumption
-
product
LXI High Voltage Switching - 10xSPST Plugin Module
65-233-904-HI
The 65-233-904-HI plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
High Voltage Probe
PD-28
Kusam Electrical Industries Limited
Most Digital Multimeters can measure AC Voltage up to 750 /1000V and DC Voltage upto 1000V DC. To extend the measuring range of the digital multi meter for low - power , high - voltage , high impedance circuits such as TV, Video Monitors.
-
product
Sample And Hold Converters
A critical part of most data acquisition systems, Renesas offers several sample and hold amplifiers for general purpose and military and defense applications that include precision data acquisition systems, synchronous sampling, wide bandwidth analog-to-digital (A/D) conversion, auto-zero circuits, digital-to-analog (D/A) converter deglitching, peak detection, and high-speed DC restore.
-
product
High Voltage Breakdown Tester
Model HV-55
Laxtronics Instruments & Controls Pvt. Ltd
5 Kilo Volt AC, 5 Kilo Volt DC, 30 Milli Ampere, Timer 0 To 100 Seconds, HV Prods, Start-Stop-Trip-Reset Using Single Switch On The Test Prods. Start Function Apply Test Voltage From 0 To Set Voltage Gradually.
-
product
Voltage Amplifiers
Switchable gain up to 100 dB (x 100,000)Bandwidth DC to 100 kHzDC-drift 0.6 µV/°CInput noise down to 0.4 nV/√HzSwitchable AC/DC-couplingLocal and remote controlInput impedance up to 1 TΩ
-
product
Static Frequency Converter Systems
Our software and connectivity devices incorporate all the features you need to proactively manage your systems, from basic monitoring and shutdown to predictive analysis and power management. Aplab Integration Services offer complete solutions tailored for the specific requirements of Defense Services, Telecom and Commercial markets.
-
product
DC/DC Converter 3.5 W
REM3.5E-2424S/R6/A/SMD
DC/DC converter with 3.5 W from Recom | input ranges 18 - 36 VDC | output 24 V | operates in ambient temperature from -40 to +95 °C | SMT package
-
product
LXI High Voltage Switching Multiplexer
65-231-914-HI
The 65-231-914-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
Non Contact Voltage Indicator
PL107N
Contact-free audible and visual indication of AC voltages between 90 and 1000 V AC Clear, omnidirectional flashing LED Quick and accurate detection of cable breaks Detects microwave leakage Phase detection in sockets Press to test switch avoids nuisance buzzing and extends battery life Supplied complete with 1.5 V AAA batteries
-
product
Digital Clamp Current Tester For High Voltage
HCL-36UX
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Display measurement value on your smartphone through blue-tooth connecting.・Measurement value can be kept in the our cloud server.・In addition to measured values, location registration by GPS, temperature, date and time can also be saved.
-
product
DC to Synchro and Linear DC to Resolver Converters
ST-LDS & ST-LDR
Computer Conversions Corporation
ST-LDS and ST-LDR Prefix - Linear DC to Synchro and Linear DC to Resolver Converters On PCB with Mounting Track having Screw-Terminal Block for ease of wiring
-
product
DC/DC Converter 2 W
REM2-1505D
DC/DC converter 2 W from Recom | input ranges 13.5 - 16.5 VDC | outputs +/-5 V | operates in ambient temperature from -40 to +95 °C
-
product
Digital 10kV High Voltage Insulation Tester
4310 IN
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
product
Ultra-low Noise High Voltage Amplifier
WMA-200
The Falco Systems WMA-200 model is a high quality, high voltage, linear laboratory amplifier optimized for experiments requiring world-class, ultra-low output noise. The excellent noise performance, combined with the wide bandwidth and large voltage range make this amplifier the preferred choice for the most demanding precision positioning systems. The amplifier will routinely enable sub-atomic positioning resolution with piezo positioning systems and MEMS devices. Two WMA-200 amplifiers and a WMA-IB-LN phase inverter - buffer can be used to double the output voltage.
-
product
12-400V AC / 12-500V DC Universal Voltage Tester
1996A
Peaceful Thriving Enterprise Co Ltd
This is convenient for low voltage, home electricity, cars and high voltage. There is 5-stage-LED-display indicators for voltage reading 12-400VAC or 12-500VDC.
-
product
High Voltage Non-Contact Current Probe
P02-0802
The TESCO High Voltage Non-Contact Current Probe (Catalog No. P02-802) was developed using current sensor technology. It is a two-piece, True RMS ammeter with a fiber optic link between the high voltage sensor and the readout at ground potential. The sensor is mounted on a hotstick and slipped over a high voltage line.
-
product
PCI Converter
ES-200
The eSATA PCI BRACKET takes the blazing speed of eSATA outside your computer case with this external plate adapter. Simply install the PCI plate in an open PCI slot on your computer and attach the SATA cable to an available motherboard connector. Now you have an external eSATA port.
-
product
Scalable High Voltage LXI Matrix
These plug-in matrices also offer built-in scan list sequence stores with triggering capability, providing users with the ability to set a series of pre-determined sequences on an LXI instrument. The sequences can be triggered by software or one of the sixteen DIO software configurable open collector triggers. They also feature multi-bus capability for parallel testing.
-
product
Low Voltage Test & Measurement
Low voltage testing is able to catch errors such as shorts and opens by applying current to a wire and measuring the voltage. The wire will have a current affected by several factors including resistance and components. If the wire is connected correctly, the test will read low resistance. That means current is flowing through the wire as expected and reaching the required connections. If the tester reads high resistance it means something is impeding the current from reaching its destination. This could be caused by a number of causes.
-
product
PXI/PXIe High Voltage Multiplexer, Dual 23-Channel, 2-Pole
40-321-128-HI
The 40-321-128-HI (PXI) and 42-321-128-HI (PXIe) are dual 23-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Scalar Mixer / Converter Measurements
S95082B
The S95082B scalar mixer / converter measurements software provides an intuitive and easy-to-use user interface for setting up mixer and converter measurements with single or dual conversion stages. It controls the analyzer’s built-in source(s) and external signal generators for use as LO signals.
-
product
Provides 3 Wire Voltage Output
SEM1620