Standard Transformers
-
Product
Transformer Regulation
-
Transformer Parallel Control System is designed to monitor & control the tap changers of up to four (4) transformers connected on a common bus & operating in a MASTER FOLLOWER control configuration.
-
Product
Split type AC Current Transformer
CTF-400T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
Synchro Control Transformer
SCT-RCT
-
Computer Conversions Corporation
The SCT Series are low cost, miniature, solid state control transformers designed for military and industrial control applications. They will directly replace conventional electromechanical control transformers & thus provide digital control to existing analog servo systems.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1A-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
-
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
Product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1V-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Instruments Transformers Tester
Calport 100 Plus
-
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T20-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Radius, Straight Shaft Bullet Nose, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0J
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Transformer Performance Tester
JYW6100
-
JYW6100 Transformer No-loads and On-loads tester power factor tester is suitable for loss testing of low power factory transformer such as amorphous alloy transformer, with high precision and data loc
-
Product
Standard Type
FD-10
-
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74E
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standards
7X
-
WENS series Frequency / Voltage / Wave / Carrier Standards is an ideal and smart solution for distributing signals from Quartz or GPS receivers. Designed to multiple output for multiple applications.
-
Product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
-
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
Product
Standard Voltage 9 Pin D-Type Cables - Connector to Unterminated for Pickering Products
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
CPSI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from a Backplane Connector P1
MIC-3811
-
It is a dual mini-PCIe carrier board with two onboard SIM card holders and mini-PCIe connectors, routed by PCIe and USB2.0 interface. It allows connection with different types of Mini PCIe form factor add on cards like Wi-Fi/3G/4G LTE/GPS/DIO/CAN/ and MVB modules, either full- or half-size style.
-
Product
Standard RF Power Sensors
-
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-R
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74A
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Current Transformer
ST-9RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
Product
Power Transformer Monitoring
-
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.