Power Factor
measures true power over apparent power.
-
Product
Automatic Power Factor Controller
-
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
Product
True RMS 1000V Wireless Multimeter w/ Power Factor
DM525
-
UEi Test & Measurement Instruments
The DM525 is a Industrial level multimeter with Wireless capability and a free App. It also has Watt/Power Factor lessening the chance of incorrect readings from ghost voltages. The increased functionality gives technicians the ability to do more.
-
Product
Automatic Power Factor Controller
-
Nippen Electrical Instruments Co.
NIPPEN Model UNO+ is used for measurement and control of PF using Reactive power compensation. Capacitor banks are suitably switched ON and OFF automatically to provide necessary compensation.An Intelligent switching algorithm (Wear leveling) ensures uniform aging of the capacitors used to achieve the Target PF. An Alarm function ensures protection of capacitor banks against abnormality in voltage, current and sets value of capacitors whenever these are beyond the higher and lower threshold limits.CT polarity is automatically sensed internally in the event of reverse connection.
-
Product
Artificial Phantom Load with Power Factor
RC-50
-
The RC-50 Artificial Phantom Load has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges. Features: Artificial Load, Light Weight, 50 Amps, 50% Power Factor.
-
Product
Power Factor Regulators
-
National Meter Industries Inc.
has been designed toenable easy, effective regulation.
-
Product
Power Factor RLC Load
3282(280V,1875W / 3700VA )
-
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
Product
GDGS Transformer Power Factor And Tan Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
Product
Power Factor Controller
R5&R8
-
DUCATI energia introduces the new and innovative R5 and R8 power factor controllers. The compactness, the latest technology and the complete range of features make the R5 and R8 models extremely adaptable to any application context in the field of power factor correction systems for both single-phase and three-phase networks of low and medium voltage with a lot of connectivity options.
-
Product
Power Factor Correction
HV/MV
-
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
Product
Clip-on Power Factor Meter & Watt Meter
-
Cambridge Instruments & Engineering Co.
Measurement of power factor in AC system on L.T. Circuits having higher current load without interrupting circuit.
-
Product
Power Quality Meter
Qualstik
-
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
Transformer Testing And Monitoring
-
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
Product
Digital Panel Meter
MPF-5A
-
Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth
-
Product
Split Core Current Transformers
-
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
Product
Mission Critical, Fault Tolerant Power Supplies
Series HSF
-
- Hot-swappable plug-in power supplies.- Designed to be combined in an N+1 fault-tolerant power system.- Front panel voltage adjustment trimmer for adjustment of output voltage.- Built-in forced current sharing and or-ing diodes.- May also be used independently as a multi-output power supply.- Designed to be sustainable - new models are backward compatible with existing racks.- Available in 1U and 3U sizes. Mounts in 19-, 23-, and 24-inch equipment racks.- All models include power factor correction (PFC).- Full service customized DC power distribution systems can match power supply output(s) with your load(s).- I/O connections via 24 pin connector that plugs into rack adapter. External connections are made via rack adapter.- Surface mount technology permits minimum mounting space.- Entire RA 19 racks populated with HSF power supplies can be connected in parallel, parallel-redundant or series.- HSF are CE Marked per per the LVD, EMC and RoHS 2 Directives. See applicable Declaration of Conformity.- Compliant with UL 8750, Standard for LED Equipment,- Watch video of NEBS GR-63-CORE earthquake and office vibration testing.
-
Product
Portable Three-Phase Phantom Load
EE-120A-3 + EE-500V-3
-
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
Product
Tap Adapter
-
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
Product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
-
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Product
Power Quality Analyzer
-
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
Product
Programmable AC Power Source
LSP-500VAC
-
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
Product
Capacitance & Tan Δ Power Factor Meter 2.5kV
CAPO 2.5
-
The measuring instrument CAPO 2.5 is a new Capacitance and tan δ / Power Factor Test Set developed by Raytech Engineers.
-
Product
3-Phase Power and Energy Analyser
PQ55A
-
* Cpmprehensive real-time monitoring, recording and analysis of 3-phase systems* Voltage measurement (true RMS)* Current measurement (true RMS)* Power factor measurement* Phase angle measurement* Power analysis (active, apparent and reactive power)* 4. Current clamp for neutral line current measurement* Suitable for use in housing construction, offices and small businesses
-
Product
3-Phase Programmable AC Source
61700
-
Chroma Systems Solutions, Inc.
Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation
-
Product
Power Analyzer
PW3390
-
The PW3390 delivers 4 input channels and ±0.04% basic accuracy for power - the top instrument in its class. Achieve more precise measurements of the power and efficiency of high efficiency equipment used in power electronics. Further, a 200 kHz measurement band and flat amplitude and phase characteristics up to high frequencies enable the precise measurement of power at top frequency levels and low power factor.
-
Product
1-phase Power Analyzers
-
PeakTech Prüf- und Messtechnik GmbH
Is a high-precision energy cost measuring device for recording the energy consumption of electrical devices and for calculating the current consumption of a device by entering the electricity price. Thanks to the integrated power factor calculation, all modern consumers such as Switching power supplies, TV sets, fluorescent lamps, LED systems and of course ohmic loads such as Electric heaters and hobs can be measured accurately. In addition, the high resolution, the low response characteristic and even very small or stand-by consumers from approx. 1 W can be measured.
-
Product
High Performance Programmable AC Power Source
61500 Series
-
Chroma 61500 Series have built in 16-bit measurement circuits and firmware utilities to measure the true RMS voltage, current, true power, apparent power, reactive power, power factor, current crest factor, and inrush current.
-
Product
AC/DC Power Clamp Tester
IBL-307
-
International Biological Laboratories
This Digital Clamp On Power Meter Model 307 can be used to measure True Power, Apparent Power and Power Factor in single phase circuits. It measures AC/DC Current and incorporates a frequency counter. It is autoranging type Digtal Clamp On Power Meter and has 3-3/4 Digits 4000 Counts with 40 segment analog bargraph LCD Display.