Filter Results By:
Products
Applications
Manufacturers
-
product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Electromagnetic
Promis 10
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
12 D/A Outputs (±10 VDC or ±25 mA)
DA1
The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).
-
product
Current Loop Expansion Kit
OP-SB85C
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
Signal Isolators & Converters
Devar current loop signal isolators reduce problems found in field measurements when signal transmitters or converters encounter both input and output signals that may be grounded. Current loop isolators eliminate these ground loops and are available as input loop powered or output loop powered instrumentation.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Digital LOOP/PSC/EARTH Tester
1824 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
product
4-port Serial Interface, Modular, With/without Optical Isolation, 3.3V/5V, With 9-pin Connectors
APCI-7500-3/4C
*This model has 4x 9-pin D-Sub male connectors on 2 brackets*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)
-
product
High-accuracy Dual-channel Programmable Battery Simulator
N8352 Series
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
N8352 series is specially designed for the R&D and testing of portable, battery-operated products , such as Bluetooth headsets, mobile, AR/VR smart terminals, electrical tools, etc. The current flows in both directions and can be used as either a power supply or a load. N8352 is easy for operation with touch screen and UI design. The output features are comparable to actual batteries, with fast dynamic response, no overshoot in voltage rise and fall, and stable waveform. The resolution is up to nA level, which can test the loop static power consumption, etc. N8352 can be widely used in the area of consumer electronics testing.
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
product
48 Ω HMM Pulse Force Probe
PHD-HMM-48-1
High Power Pulse Instruments GmbH
*High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability
-
product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TC
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Digital LOOP/PSC/LOAD Tester
1825 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
product
LOOP/RCD Testers
It can measure trip-out current, trip-out time, on-line voltage, loop resistance and frequency etc. It’s ideal tool for electrical inspection and repair.Comply with IEC/EN 61010-1 1000V CAT III, 600V CAT IV safety standards.Max common mode voltage: 600V AC RMS.
-
product
Hall Effect DC Current Sensor
CYHCT-L20K
ChenYang Technologies GmbH & Co. KG
The sensor CYHCT-L20K is based on open loop principle and designed with a high galvanic isolationbetween primary conductor and secondary circuit. It can be used for measurement of DC current, DCpulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
product
Multifunction Meter for Electrical Installations
AMPI-530
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
product
Multifunction Installation Testers
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Calibrator Process
VA70034
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
product
Intelligent Transmitter with Digital Indication
LEO 3
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions: