Phase Standards
verify Phase Meters, Vector Voltmeters, Broadband Wattmeters and Power Analyzers, Resolvers and other Phase Sensitive Instruments.
See Also: Phase, Phasing, Phase Meters, Phase Angle, 3 Phase
-
Product
Standard Amplifiers
-
Teledyne RF & Microwave, a Business Unit of Teledyne Microwave Solutions (TMS), supplies catalog and custom RF and microwave amplifier designs for aerospace, defense, and industrial applications. These standard amplifiers, originally designed by Teledyne Cougar, provide both excellent stability and cascadability.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1F-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Voltage Controlled Phase Shifters To 3200 MHz
-
Pulsar's Voltage Controlled Phase shifters utilize a DC voltage to control the phase of the RF signal applied. These phase shifters utilize varactor diodes to produce the necessary phase requirements. Phase of the 180 and 360 degree designs are available, and phase can be controlled with a DC voltage 0-20 Vdc. Modulation of these phase shifters is typically 100 kHz, and maximum input power is +5 dBm.A wide variety of package styles are available, such as plug-in, flatpack, TO-cans, and connectorized housings, though the most popular are the miniature surface mount packages. Surface mount packages are available on tape and reel, for automated assembly techniques.
-
Product
GPS Time and Frequency Standards
-
Our range of GPS disciplined Rubidium Oscillator, OCXO and TCXO, low cost and stable, time and frequency references in a variety of rack mount and desktop sizes to suit all applications. For a technical discussion of GPS go here or select a link below for product information.
-
Product
Standard C23 20x30 Mm Photoelectric Sensors
-
Contrinex Standard C23 20x30 Mm Photoelectric Sensors
-
Product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
-
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.
-
Product
Standard Shackle Load Cell
SS-3.0
-
The DLM Standard Shackle Load Cell is a high strength marine grade cable connected Load Cell. Manufactured from industry leading Crosby or GN Shackles along with a stainless steel load pin.
-
Product
Hydrogen Frequency & Time Standard
CH1-1007
-
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Single Phase Energy Meter Test Bench Type KP-S1000-A
-
Bofa Instrument & Equipment Co., Ltd
Single phase test bench, type KP-S1000-A, is a new generation, high precision energy meter calibration equipment. It can test mechanical energy meter and electronic energy meter, in spite of open or closed test link (I-P link). It is an ideal testing equipment for energy meter factory or R&D institute. All the testing procedures can be automatically operated by PC or by Keyboard manually.
-
Product
Standard 1.27 (36.00) - 2.94 (83.35) Battery Probe
CCA-003
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 670Overall Length (mm): 17.02
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard Control and Alarm Panel
8040
-
From our range of B/W Controls products we can supply the 8040 Series control panel with control relay, wired terminal block, motor starter, or a panel for just the external connections.Included in the 8040 Series standard control and alarm panel is the B/W system wiring diagram which assures quick and easy installation and the confidence that the system will work right the first time.
-
Product
Low Phase Noise Amplifier
-
RF Lambda’s lower phase noise amplifier offerings include special power supply conditioning and utilize technology to reduce the phase noise addition from amplifying the signal. Hermetically sealed options are available upon request.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HF-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
NanoCD Standards (NCD)
-
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
Product
Standard Modal Analysis
-
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4S
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Rail Wheel Testing Using Phased Array System
ECHOMAC® PA Wheel Tester
-
MAC introduces two versions of Rail Wheel Testers using ECHOMAC® PA platform based on customer requirements. One is a semi-automated solution using local immersion technique. Used for tread inspection of new and/or reprofiled wheels. This solution meets or exceeds EN13262, ISO5948 or AAR M-107/M-208 standards for tread inspection. The second solution is a fully automated immersion tank. Performs tread and face inspection of rail wheels using two phased array probes simultaneously. This solution meets or exceeds EN13262, ISO5948 or AAR M-107/M-208 standards for tread and face inspection, while monitoring the backwall on the face side per EN 13262.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Spectral Phase Measurement
Avoca SPIDER System
-
Spectral phase interferometry for direct electric-field reconstruction (SPIDER) is one technique that can recover the spectral phase of an input pulse, without needing any reference pulse. SPIDER interferes two pulses which areseparated in time and in frequency, and the resultantinterferogram is read by a spectrometer.
-
Product
Two Channel Phase and Amplitude Noise Analyzer
DCNTS -190
-
The DCNTS is a two channel Phase and Amplitude noise analyzer. Its dual demodulator architecture allows the system to use cross-correlation to cancel its internal noise and limitation; it is like comparing the outputs of 2 systems and only display the similarities while rejecting differences. Its main extension is the Residual Noise measurement front-end which includes all necessary hardware to automatically measure residual noise on 2-ports devices either in RF frequencies or microwave. It could be a frequency multiplier or divider, an amplifier or any other phase coherent input to output device.
-
Product
Analog Phase Shifter
-
Analog Devices analog phase shifters change the phase of RF, microwave, and millimeter wave signals. Our technology features consistent insertion loss vs. phase shift, monotonic phase shift, low insertion loss, and a compact size that makes it ideal for multiple applications, including:• Fiber optics• Military• Test equipment
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76