Voltage
The tension of an electromotive force.
-
Product
Ruggedized Ethernet Data Acquisition Systems
Series 7000
-
The Series 7000 Ruggedized Ethernet DAS brings new capabilities and levels of performance to transducer data acquisition. The ruggedized system is designed for installation in wind tunnels, engine test stands and other facilities where it is desired to locate the DAS on or near the test article, reducing installation and cable costs while improving signal quality and reliability. Each unit is a network appliance which conditions, amplifies and digitizes outputs from transducers. Multiple units are easily combined and distributable for larger installations. Real-time temperature Compensation of gain offset and Excitation Voltage, quality signal conditioning with high gain and a 24-Bit A/D per channel provide a high accuracy and high resolution DAS that will perform across a wide operating range.
-
Product
FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ
785641-01
-
8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.
-
Product
Semiconductor Curve Tracer
CS-3000 Series
-
*Max. Peak Voltage : 3,000V(HV mode)*Max. Peak Current : 1,000A(HC mode)*Equipped all models with LEAKAGE mode (Cursor resolution 1pA)*USB port for display hardcopy, waveform data (CSV format) and measurement setup SAVE/RECALL*LAN interface for Remote Control
-
Product
Variable Gain High Speed Linear Amplifier
F30PV
-
The F30PV is a very fast general purpose linear amplifier having a variable amplification of 0-10 times and capable of bipolar voltage output of ±35V. Any functiongenerator or arbitrary waveform generatoror any othe signal source can be used as an input device. The amplifier's output is linear from DC up to ca 10 megahertz range. It can be used in a wide range of high speed applications.
-
Product
High Resolution Oscilloscopes
PicoScope® 4000 Series
-
High voltage and power electronics.Single & 3 phase voltage/current.SMPS design and test.Motor drives and inverters.Hybrid and EV design.
-
Product
Multiphase Power Analyzer
2800 Series
-
The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions. All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging. All is built into the input sections of the power analyzer, ready for measurements. It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.
-
Product
PXIe High Voltage Programmable Resistor Module, REDEL Connector
42-230-332-HI
-
The 40-230-332-HI (PXI) and 42-230-332-HI (PXIe) are programmable resistor modules with 1 channel which can be set between 3.5Ω and 26.7kΩ with 0.5Ω resolution with maximum voltage of 1.2kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
PXIe High Voltage Programmable Resistor Module, D-Type Connector
42-230-141-HI
-
The 40-230-141-HI (PXI) and 42-230-141-HI (PXIe) are programmable resistor modules with 1 channel which can be set between 4Ω and 201kΩ with 0.25Ω resolution with maximum voltage of 1kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Programmable AC Source
6500
-
Chroma Systems Solutions, Inc.
1200VA ~ 9KVADirect Digital Synthesis (DDS) waveform generationProgrammable voltage, current limit, frequency, phase, and distortion
-
Product
PXI 2 Amp MUX, Quad 4-Channel 2-Pole
40-635-109
-
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Complete Power Analysis System
PK3564-PRO+
-
PK3564-PRO+ complete Power Analysis System includes PS3550 Power Analyzer, AC charger, Quick-Start manual, deluxe voltage leads, four eFX6000 flexible current probes, SD memory card, PSM-A Software, Mini Line-to-DC Converter, Bluetooth Adapter, USB Communications Cable, CASW Weather-Resistant Carrying/Operating Case, and 2-year deluxe warranty.
-
Product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
-
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
-
Product
TimerBlox
-
Analog Devices TimerBlox parts are small, accurate, and simple timing devices designed for six basic operations: voltage controlled oscillation (VCO), low frequency clocking, pulse-width modulation (PWM), one-shot generation and signal delay, and power-on reset (POR). TimerBlox devices combine an accurate programmable oscillator with precision circuitry and logic. No capacitors, no crystals, no microcontroller, and no programming are required. A 20 mA source and sink capability enables the devices to directly drive opto-isolators and transformers for electrical isolation. An ideal solution for space-limited applications, each TimerBlox device can be placed at the point of use.
-
Product
PXIe High Voltage Programmable Resistor Module, D-Type Connector
42-230-050-HI
-
The 40-230-050-HI (PXI) and 42-230-050-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 4.5Ω and 1.5MΩ with 0.125Ω resolution with maximum voltage of 1kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Fast Digital Integrator
FDI2056
-
The Fast Digital Integrator FDI2056 is the world's fastest and most sensitive voltage integrator. Simply plug in a sense coil and measure fast, low-level magnetic field disturbances such as eddy currents in a switched magnet.Equipped with a high-speed Analog-to-Digital Converter (ADC), high-resolution clock, and highly optimized digital integrator, the FDI2056 boasts a maximum of 500 000 partial integrals per second and provides resolutions down to 10-14 Vs with an accuracy of 10 ppm. Magnetometer Fluxmeter
-
Product
AC/DC Digital Clamp Tester (CE)
M-260
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
Product
Power Meters
-
The new range of Hobut multifunction panel meters feature 96 x 96mm sizes complete with unique blue LED screen, which can be seen in direct sunlight. The range is easy to use, features user-programmable CT & VT ratios, and can be used on any single or 3 phase system with any input voltage without re-programming.
-
Product
Source Measurement Unit
DPS16
-
The DPS16 offers high voltage DPS in a compact, 3U PXI form factor. The DPS16 supports 0V to +4V 0.3A or 0V to 12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 16 channel can be ganged to support high current driving.
-
Product
Multichannel Recorder-Analyzer
-
Portable measuring complex for control, registration and analysis of parameters of electrical devices of the subway and railway.The measuring unit of the portable recorder of electrical devices is based on the measuring equipment of the NI CompactRIO platform manufactured by National Instruments (USA, www.ni.com ), which is placed in a special case for transporting the Pelican-Storm iM2450 with an instrument front panel and connectors for connecting a source (s ) power supply, user's workstation computer and sources of measured voltage current signals.
-
Product
High Density, Low Noise, Floating Low Voltage Power Supply System
PL500 Series
-
The WIENER PL500 is a high density, low noise, floating low voltage power supply system. The PL500-Series has been designed to power lowest noise electronics with medium to high currents (10A to 500A current/channel range) over long distances in voltage or current controlled mode. Operating in either un-sensed or sensed mode the dynamic behavior can be set internally or by software for short, medium or long distances.
-
Product
PXI High Voltage Power Multiplexer, Octal 3:1 (SP3T)
40-331A-005
-
The 40-331A-005 octal 3:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
Product
Dielectric Withstand Tester
-
Weshine Electric Manufacturing Co., Ltd
The induction withstand voltage test of transformers and transformers is an important test to ensure that the quality of transformers conforms to national standards. The longitudinal insulation induction withstand voltage test of the inter-turn, inter-layer, inter-section and inter-phase insulation of the transformer winding is an important item in the transformer insulation test.
-
Product
AC Power Source
LSP-500VAR
-
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
Product
Clamp type AC Current Sensor/with DC Voltage Output
ACT-50H
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For current measurements of the control board*AC 1A~50A*DC 5V full scale output
-
Product
200-Pin LFH Connector, PCB Mount, Right Angle Female
40-963-200-RF
-
Accessory allows a user to create their own PCB based termination solution mounted directly on the front of the product or on the end of a cable. It is suitable for use with a variety of products. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires.
-
Product
HV Coupling Capacitors
-
Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.
-
Product
PXI 16x SPST High Voltage Reed Relays
40-310-101
-
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
Product
PCI Daughter Boards
DB-24SSR/D/DIN (DB-24SSR/D with DIN-Rail Mounting)
-
The DB-24SSR/DB-24SSRDC includes 24 normally open, or form A, solid-state relays The board interface to filed logic signals, eliminating ground-loop problems and isolating the host computer from damaging voltages. The user can use the DB-24SSR/DB-24SSRDC to switch high voltage load, up to 240 VAC/50 VDC and up to 4 A. The relay is energized by applying a 5-voltage signal to the appropriate relay channel on the 50-pin header or 37-pin D-sub connector. Twenty-four enunciator LEDs, one for each relay, light when their associated relay is activated. Because there is a D-sub 37-pin connector on the board, the user may use it to interface to any TTL output board. In other words, the user may use it as a general purpose solid state relay output board.
-
Product
Supercapacitor Test
-
The CT3001A/C battery test systems are upgraded from CT2001A/C with higher precision and data logging rate. The tester can be used to run precision tests for coin cells, pouch cells, prismatic cells, and especially supercapacitors (ultra-capacitors). Each tester has 8 independent channel which can be programmed to run constant current charge/discharge, constant voltage charge, constant power discharge, constant resistant discharge, and direct current internal resistance (DCIR) tests.
-
Product
Dual Channel HV Amplifier with Phase Inverter
A400DI
-
This unit contains two independent A400 amplifiers that share common ground reference and power supply. Please see A400 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase. Connecting a load between the outputs effectively doubles the amplitude range. Please note that the load cannot have any connection to ground.