Cable Fault Locators
Use time domain reflectometry to locate signal loss or a Murray loop bridge.
See Also: Cable TDR, Cable Sheath
-
Product
Universal Locator
UL 30
-
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
Product
Cable Route Tracing and Identification
-
Cable pinpointers and fault locators from Megger make the process of cable route tracing and identification quicker and more accurate. These pinpointing systems are portable for everyday fieldwork and provide services from power and telecoms to water, rail and gas utilities. HV and LV buried cables can be traced to a depth of up to 5m.
-
Product
Time-Domain Reflectometer
TDR-410
-
*Location damaged power cables.*Fault location copper telecom cables.*Coaxial cable fault location.*Fault location wiring infrastructure.*Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.*Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.
-
Product
Cable Fault Locator
FaultCaster
-
Low Cost Full specification Professional Digital TDR Measures Distances to Open or Short Circuit Faults Extended Measuring Range to 2000m (6000ft) on all cable types Fast-Edge Step TDR technology for improved range & Resolution
-
Product
Software Package
System Software 3
-
The BAUR system software is a cable testing, cable diagnostics and cable fault location package. It enables efficient monitoring of the condition of cable networks in combination with BAUR cable fault location, testing and diagnostics systems.
-
Product
Burn Down Transformer
ATG 6000
-
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
Product
Tool, Locator, TriPaddle, Receiver
910104146
Locator Tool
Tool, Locator, TriPaddle, Receiver (only for contact p/n #'s 610110128 Rev C+ and 610110177)
-
Product
Audio Frequency Generator
TM530
-
TM530 Audio Frequency Generator is provided with Pinpoint Fault Locator for pinpointing the low resistance fault and detecting cable route. When detecting, TM530 will inject a signal current of 1kHz audio frequency into the cable, and accordingly a magnetic wave of the corresponding frequency will be generated on the cable. Pinpoint Fault Locator will collect this magnetic signal, thus obtains the information of the cable fault and the route.
-
Product
Surge Voltage Generator
SSG 1100
-
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Surge Voltage Generator
SSG 500
-
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Tool, Locator, Thermocouple, ITA
910104135
Locator Tool
Used with Crimp Tool p/n # 910101102 to crimp thermocouple ITA contacts.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Tool, Locator, Micro Coax, Receiver
910101135
Locator Tool
Included with Crimp tool kit p/n 910101132 and kit p/n 910101131.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.