Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
Product
Integrating Spheres
-
Integrating spheres for measurement systems for light and optical radiation, transmission, reflection and absorption. For integrating sphere light sources or based material for customer integration of e.g. PTFE based integrating spheres. We as an experienced manufacturer of integrating spheres can surely implement your application ideally! Either based on standard integrating sphere systems or individually configured integrating sphere setups.
-
Product
Integrating Spheres
IS-*M
-
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
Product
Integrating Spheres With Synthetic Coating
-
Integrating spheres with synthetic ODM98 coating. Precise CNC machining. Diameter from 8 mm to 250 mm.
-
Product
Integrating Spheres For Reflection, Transmission And Absorption
-
Integrating spheres and accessories optimized for the measurement of reflection, transmission, absorption and photoluminescence.
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
Product
Integrating Spheres
-
All our spheres can be coupled to our high performance spectroradiometer systems for UV-visible-IR spectral power distribution measurements yielding full colour information including colour rendering indices, chromaticity co-ordinates, colour temperature, etc. Alternatively precision photometric detectors can be fitted for direct total lumen output measurements.
-
Product
Integrating Spheres
IP-Series
-
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
Product
Integrating Spheres For Reflection, Transmission, Absorption
-
Universal integrating spheres and accessories optimized for the measurement of reflection, transmission, absorption and photoluminescence
-
Product
Integrating Spheres & Absolute Flux Integrators
-
Photometric Solutions International Pty Ltd
PSI’s LF series integrating sphere photometers are widely regarded as excellent quality, robust equipment for industrial or laboratory applications.
-
Product
Integrating Spheres
-
Artifex Engineering GmbH & Co. KG
We offer integrating spheres made from a special polymer suitable for the wavelength range 250nm – 2.5 µm. For longer wavelengths in the range 700nm – 20 µm, a gold coating on a rough, metallic surface is used. Since lasers in this spectral range are usually also high power, we use solid copper as a thermally conductive substrate material. By choosing the size of the integrating sphere, the overall sensitivity of the system can be adjusted. In addition, the detector is independent of inhomogeneities in power density and polarization. The detector is also independent of the incidence location and angle of the laser radiation.
-
Product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
-
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
-
Product
Broadband Light Meters With Integrating Sphere
-
Broadband light meters with integrating sphere for measuring laser power (W) and luminous flux (lm).
-
Product
Precision Kelvin Holders
MH-4 Series
-
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
Product
Integrating Sphere With Holder Base
IS-*MA
-
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Integration Spheres
-
Offers a wide range of integration spheres (0.25m to 3 m diameter) and spectrometer options, application-specific modules as well.
-
Product
UDT-Series Integrating Sphere Systems
-
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
Product
*High Speed, Multifunctional Integrating Spheres
-
Multifunctional integrating spheres enable simultaneous measurement of multiple laser parameters including:*Power*Pulse Characteristics*Spectrum
-
Product
Integrating Sphere Based Spectroradiometer Systems
-
Spectroradiometer systems with integrating sphere for the measurement of UV-VIS-NIR spectral radiant flux (W/nm) and luminous flux (lm) and chromaticity metrics.
-
Product
Constant Temperature Integrating Sphere
IS-*MT
-
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Integrating Sphere
-
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
UV-VIS-NIR Spectrophotometer
UV-3600i Plus
-
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples. LabSolutions UV-Vis is a next-generation Shimadzu UV control software pursuing efficiency of analysis. LabSolutions UV-Vis software with easy-to-use is included as standard.
-
Product
UV-VIS Spectrophotometer
UV-i Selection
-
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
Integrating Sphere Solutions
-
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
Product
Integrating Spheres For UV
-
Konica Minolta Sensing Americas, Inc
Instrument Systems offers complete measurement solutions for UV-A, -B and -C radiation starting from 200 nm. The operation of the well-proven Instrument Systems spectroradiometers, e.g. CAS series, with integrating spheres made from PTFE facilitate high sensitivity measurements of UV radiant flux.
-
Product
LED Tester0.3m-2m Integrating Sphere
CX-8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Integrating Spheres - Luminous Flux Measurement For LEDs And Lamps
-
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.





























