Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Integrating Spheres
Artifex Engineering GmbH & Co. KG
We offer integrating spheres made from a special polymer suitable for the wavelength range 250nm – 2.5 µm. For longer wavelengths in the range 700nm – 20 µm, a gold coating on a rough, metallic surface is used. Since lasers in this spectral range are usually also high power, we use solid copper as a thermally conductive substrate material. By choosing the size of the integrating sphere, the overall sensitivity of the system can be adjusted. In addition, the detector is independent of inhomogeneities in power density and polarization. The detector is also independent of the incidence location and angle of the laser radiation.
-
product
Integrating Spheres
All our spheres can be coupled to our high performance spectroradiometer systems for UV-visible-IR spectral power distribution measurements yielding full colour information including colour rendering indices, chromaticity co-ordinates, colour temperature, etc. Alternatively precision photometric detectors can be fitted for direct total lumen output measurements.
-
product
Integrating Spheres
IS-*M
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
Integrating Spheres & Absolute Flux Integrators
Photometric Solutions International Pty Ltd
PSI’s LF series integrating sphere photometers are widely regarded as excellent quality, robust equipment for industrial or laboratory applications.
-
product
Integrating Spheres With Synthetic Coating
Integrating spheres with synthetic ODM98 coating. Precise CNC machining. Diameter from 8 mm to 250 mm.
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
product
IR/Visible Target Projectors
Santa Barbara Infrared’s reflective infrared and visible target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) and visible imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies, Infinity VSX Integrating Spheres and 300 Series Target Wheels.
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
Integration Spheres
Offers a wide range of integration spheres (0.25m to 3 m diameter) and spectrometer options, application-specific modules as well.
-
product
Broadband Light Meters With Integrating Sphere
Broadband light meters with integrating sphere for measuring laser power (W) and luminous flux (lm).
-
product
New Design 3m Electric Integrating Sphere
IS-3.0MA
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
Uniformity Calibration Standards
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Integrating Sphere Construction Kit
A universal kit for the custom configuration of integrating spheres and integrating sphere light sources. The use of standard components provides cost effective and timely implementation. Complete solutions for measuring systems and integrating sphere light sources.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
product
UV-VIS Spectrophotometer
UV-i Selection
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Integrating Sphere Light Sources
Integrating sphere light sources with LED based or continuous broadband emission spectrum for use as luminance standards for camera calibration, for the determination of veiling glare, for the adjustment of night vision devices and much more. Diameters in the range from 50 mm to 500 mm with options like monitor detector, signal output control by manual and remote apertures and much more.
-
product
Integrating Spheres For Reflection, Transmission, Absorption
Universal integrating spheres and accessories optimized for the measurement of reflection, transmission, absorption and photoluminescence
-
product
Integrating Spheres
Integrating spheres are used especially for measuring divergent light sources such as LEDs. The light is introduced through the input port, then reflected many times by the highly reflective interior of the sphere until it illuminates the inner surface uniformly. A detector samples a small fraction of this light to measure the total power input. Ophir integrating spheres have a highly reflective diffuse white coating for measurements independent of beam size, position and divergence. There are several sphere sizes, apertures and wavelength regions available. The large IS6 series has 2 configurations for measuring divergent or parallel beams.
-
product
High Power Optical Head With Integrating Sphere
81628C
The 81628C High-Power Optical Head features an integrated sphere that enables it to handle power levels up to +40 dBm (with heat sink), across 800 nm to 1700 nm wavelength range. It provides the highest accuracy at high power within the family.
-
product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.