-
Product
Carbon / Sulfur Analyzer
ELEMENTRAC CHS‑r
-
The ELEMENTRAC CHS-r elemental analyzer determines the elements carbon, sulfur and hydrogen by combustion of the sample in an oxygen stream and subsequent measurement of the combustion gases CO2, SO2 and H2O in selective infrared measuring cells. A high sample weight of up to 500 mg ensures excellent reproducibility of the measurement results, even for heterogeneous samples.
-
Product
Galvanic DO Sensor
Model 20
-
The Model 20 Galvanic DO Sensor utilizes proven galvanic sensing technology – without a question the most accurate and reliable DO sensing technology ever developed. The pure platinum cathode makes the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. This sensor utilizes the only DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It is also the only sensor design that can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes.
-
Product
Intrinsically Safe In-line Hydrogen Process Analyzer
HY-OPTIMA™ 1700 Series
-
H2scan’s HY-OPTIMA™ 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60ºC. The HY-OPTIMA™ 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.
-
Product
CHNO Combustion Services
-
Carbon, Hydrogen, Nitrogen are determined using a 2400 Perkin-Elmer CHN Analyzer. This analyzer uses combustion to convert the sample elements to simple gasses, i.e. CO2, H2O, & N2. Upon entering the analyzer, the sample is combusted in pure oxygen environment at temperatures in the range of 1200-1500 F. The product gasses are separated under steady state conditions, and measured as a function of thermal conductivity.
-
Product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
-
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
Product
Hydrogen Analyzer
H‑500
-
Determination of hydrogen using the heat extraction method is a special requirement for the characterization of steel, steel alloys, copper and other metals. ELTRA’s H-500 is designed for the rapid and accurate determination of hydrogen in these materials. The H-500 analyzer uses the heat extraction technique and is equipped with a resistance furnace with quartz tube. The temperature can be set up to 1000 °C in steps of 1 °C. The usual working range of the H-500 is about 900° to 1000° C.
-
Product
Tracer Gas Leak Testers
-
At ATEQ, we understand how essential it is to detect hydrogen leaks as swiftly as possible. For this reason, we carry our own high-quality gas tracer equipment. One of popular tools is the H 6000, which is a multipurpose, handheld hydrogen leak detector designed to identify a broad spectrum of hydrogen gas concentrations. You can use this instrument for multiple applications like automotive and HVAC.
-
Product
CS/ONH-Analysis
G6 LEONARDO
-
The high-end thermal conductivity detector used for hydrogen and nitrogen analysis allows detection limits in a sub-ppm range (based on 1g sample mass)
-
Product
Inorganic Elemental Analysis
-
Elementar Analysensysteme GmbH
The elemental composition of a material determines its properties. Elemental analysis is therefore essential for the characterization and quality control of materials that need to meet certain requirements.Elementar's user-friendly inductar® series for inorganic elmental analysis uses the high-temperature combustion method to determine elemental concentrations of carbon, sulfur, oxygen, nitrogen, and hydrogen and is the ideal solution for R&D, routine, and high-throughput laboratories.
-
Product
UV Fluorescence H2S, SO2 Analyzer
Model T101
-
Teledyne Advanced Pollution Instrumentation
The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
-
Product
Gas Analyzers
-
Here you will find gas analyzers that meet industry standards relating to personal safety and that are mainly used to detect and measure levels of methane, hydrogen sulphide, carbon monoxide, oxygen and 50 other gases. The auto-calibration function allows for easy calibration. Some of them also possess the ability to store values and can later transfer data to a computer. One accessory is the manual aspirator, with this device, you can draw gas directly into the analyzer via a 2 m long tube with which you will be able to measure gas levels without having to be in direct contact to the gas source or to be able to determine the levels of gas in places that are difficult to access.
-
Product
Enhanced SCR Power Controller
Thyro-PX DC
-
The Thyro-PX DC series shapes the future of the growing hydrogen and DC heating markets. The SCR power controller series takes advantage of the existing Thyro-PX controller card architecture and is available as three-phase units, supports up to 1800 amps DC Current, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display and enable efficient system parameters, loading, and storage via an onboard SD-card. The Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.
-
Product
Gas Meters
-
At PCE Instruments you will find a professional quality gas meters for everyday use. The gas detector meets the requirements for personal safety and issued mainly for the detection of methane, hydrogen sulphide, carbon monoxide and oxygen levels (along with 50 other possible gases). The auto-calibration function allows for easy recalibration of the gas detector. Depending on the model, the gas detector has the ability to store data and later transfer recorded values to a computer.One accessory is the manual aspirator, with this device you can draw gas directly into the gas detection instrument via a 2 m long tube with which you will be able to measure gas levels without having to be in direct contact with the gas source or to be able to determine the levels of gas in places that are difficult to access. Furthermore, we have a fixed installation gas detector in many different models available.
-
Product
Organic Elemental Analysis
-
Elementar Analysensysteme GmbH
Carbon, hydrogen, nitrogen, oxygen and sulfur are the basic elements of living nature. Their quantitative determination in the most versatile combinations of substances, the elemental analysis, is the origin and essence of the Elementar product portfolio.
-
Product
Mobile Gas Flare
-
Small-sized and quickly ready-for-use gas flare for safe flaring applications of natural gas,hydrogen or other combustible gases.For reduction of operational methane emissions during commissioning and decommissioningof gas service lines in the house connection area (according German DVGW worksheet G 404).Suitbale for emptying of gas tank facilities.
-
Product
Hydrogen Gas Analyzer
HyEVO
-
High-accuracy, high-resolution hydrogen gas analyzer designed to support the development of the hydrogen supply chain.Essential for the development of technologies necessary to produce, transport and use hydrogen and hydrogen related materials such as ammonia.HyEVO can be used for many applications in combination with other measurement devices.
-
Product
Gas Filters
-
WITT gas filters enable the finest filtering of impurities in technical gases such as acetylene, argon., oxygen, hydrogen, methane, carbon dioxide, helium, compressed air and ethylene. They thus protect downstream equipment and systems. Some gas filters are also referred to as gas cleaners.
-
Product
GRIDSCAN 5000
Hydrogen Series
-
The H2scan GRIDSCAN 5000 Hydrogen Sensor pairs a high performance ASIC to H2scan’s field-proven solid-state hydrogen sensor. This stand-alone sensor system has been designed to provide precision hydrogen measurement, at a lower cost for the high-volume OEM or utilities. No calibrations or maintenance is needed for up to 10 years, and the GRIDSCAN 5000 is the lowest cost by thousands to any other available hydrogen DGA system. H2scan is the only company in the industry that can state retail sales of over 15,000 sensor systems worldwide with no after sale calibrations performed since 2012.
-
Product
Toxic Gas Detector
SMC 5100-XX-IT
-
The SMC 5100-XX-IT gas detector monitors toxic gases such as Hydrogen Sulfide, Carbon Monoxide, Nitrogen Dioxide, Ammonia, Oxygen Deficiency, and others. The detector requires calibration only every six months, cutting operating costs and time.
-
Product
Oxygen Logger Sensor
NUL-205
-
This sensor can be used to make measurements of the level of free oxygen in air or dissolved oxygen in water. The free oxygen in air mode is used to measure changes in oxygen levels during combustion or in reactions that produce oxygen (hydrogen peroxide decomposition). The dissolved and free oxygen modes are very useful in the study of photosynthesis.
-
Product
H2 and Binary Gas Analyzers
-
PST offer a range of hydrogen (H2) and binary gas analyzers utilising the thermal conductivity property of gases to determine the concentration of a Target Gas (hydrogen for example) within a known Background Gas such as oxygen, nitrogen or argon.
-
Product
Elemental Analyzer
-
CHANGSHA KAIYUAN INSTRUMENTS CO., LTD.
Elemental Analyzer is used to determine carbon, hydrogen, nitrogen content in solid and liquid material, such as coal, coke, oil, petroleum, biomass, fertilizer, plastic, food, hydrocarbons and plant tissue, leaves and tobacco, which is widely applied in power plants, coal mines, metallurgy, chemical industry, commercial inspection, scientific research, food industry, education etc.
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Motive Power Gas Detection
-
Protecting your employees and facilities from dangerous gas buildup—whether through hydrogen gas detectors, carbon monoxide detectors, or other specialized monitors—is essential for preserving lives and property. Implementing a gas detection system ensures a safe working environment while maintaining productivity and meeting regulatory requirements.
-
Product
UV/IR Flame Detector for Hydrogen Apps
-
The FL500-H2 is an Ultraviolet / Infrared flame detector designed specifically to detect hydrogen (H2) fires. The FL500-H2 optical flame detector monitors for radiation emitted by a hydrogen flame in both the ultraviolet (UV) and infrared (IR) spectral ranges.
-
Product
Coupler Workstations
-
Workstations using pure hydrogen gas from a tabletop generator, tank supply, or oxygen, can achieve high enough temperatures to develop Fused Biconic Tapered devices, Power Combiners, Wavelength Division Multiplexers, Thermal Core Expansion devices, and many other products.
-
Product
Hydrogen Fluoride Gas Monitor
GASERA ONE HF
-
Hydrogen fluoride, chemical formula HF, is a colorless, highly irritating already at very low ppm levels, corrosive gas and can exist as a fuming liquid. Reaction with water is rapid, producing heat and hydrofluoric acid. Hydrogen fluoride (HF) is used in manufacturing of refrigerants, herbicides, pharmaceuticals, high-octane gasoline, aluminum, plastics, electrical components, and fluorescent light bulbs, among others. Hydrogen fluoride (HF) is very soluble in water and is readily absorbed in the upper respiratory tract.
-
Product
Clock And Timing
-
Achieving highly accurate precision timing is no easy feat from a technology perspective, so it’s important to find a resource you can trust to reduce design risk and speed your time to market. Our end-to-end timing solutions generate, distribute and apply precise time for multiple industries, including communications, aerospace and defense, IT infrastructure, financial services, power utilities and more. We provide a broad range of clock and timing solutions ranging from MEMS oscillators to active hydrogen masers. Explore our portfolio of clock and timing components and systems to find the right solution for your project.
-
Product
H2S Analyzers
-
Our portable and fixed gas analyzers measure hydrogen sulphide (H2S) in natural gas. H2S is a naturally occurring, but very toxic gas and needs to be removed before transmission to the national gas grids.





























