Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
-
product
MIPI Soundwire Total IP Solutions
Soundwire
Soundwire is suited for small, cost-sensitive audio peripherals such as modern digital class-D amplifiers and digital microphones. The Total MIPI SoundWire IP Solution from Arasan enables early adopters the fastest path to adoption of this new standard by offering a comprehensive IP package that includes the Verilog RTL source code for Master and Slave, fully validated for compliance with the standard, a comprehensive test environment with a compliance suite for verification of the IP package, a SoundWire Hardware Development Kit (“HDK”) for FPGA prototyping, a SoundWire protocol analyzer and a complete SoundWire software stack.
-
product
Modulation Distortion Up To 26.5 GHz
S930702B
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Harmonic Filter Resistors
Post Glover designs, builds and tests their harmonic filter resistors in accordance with applicable IEC and IEEE standards to guarantee their performance. With no two installations ever being the same, our experienced engineers develop the proper solution for your particular application and environment. Our low inductance designs are built using all stainless steel elements in corrosion resistant enclosures chosen for your unique specification. Request a quote for your custom harmonic filter resistor.
-
product
Total Luminous Flux Measurement System
This system enables the total luminous flux measurement of luminous intensity distribution 2 and 4 light sources based on the measurement standards of LED lightings LM-78 and LM-79 approved by IESNA (Illuminating Engineering society of North America) .
-
product
Total Organic Carbon Analyzer
Model 6700E
Teledyne Analytical Instruments
Online monitoring of total organic carbon is essential for regulatory and process control purposes among water treatment, wastewater and industrial users. Teledyne’s 6700E Series employs proven UV-Persulfate methodology to isolate only organic carbons, oxidize them into carbon dioxide and measure TOC in the gas phase using infrared absorption technology. This method conforms to EPA, DIN, CE, ASTM and NAMUR regulations as well as meeting requirements of ISO and EN directives.
-
product
Total Stations
Zoom50 Series
When you need highest performance on all levels even under most challenging conditions, the GeoMax Zoom50 series is the perfect choice for you. The longer measurement range means a wider operational coverage and significant less time lost with switching setups. The new PowerLock protection mechanism prevents use by unauthorized persons and deters theft.
-
product
Total Stations
Zipp02 Series
With vertical compensation and 2” accuracy the Zipp02 provides you with the precision required for your most demanding jobs at an affordable price without adding complexity. The Zipp02 is the tool of your choice when it comes to checking angles, alignments, grade work and short range leveling.
-
product
Digital Power Meter (High Accuracy Model)
LS2050
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
product
Total Sulfur Analyzer
Model T108
Teledyne Advanced Pollution Instrumentation
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.
-
product
Intermodulation Distortion Measurements
S96087B
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S96087B software application with the ENA
-
product
Total Organic Carbon Monitor
HT-110
The continuous online TOC-Analyzer HT-110 is suitable for the measurement ot total organic carbons in Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). The unit is operating according to USP 643. It is applicable for pharmaceutical and/or semiconductor manufacturing. The measuring principle is based on UV-Oxidation and measurement of the difference in conductivity. TOC concentration measurement (TOC concentration 500 ppbC or lower) is necessary to perform quality control according to GMP (Good Manufacturing Practice).
-
product
Total Hydrocarbon THC/VOC Monitoring System
ML661
The Teledyne ML®661 is a complete engineered CEMS designed to measure total hydrocarbons (THC/VOC) as required in environmental regulatory compliance and process control applications. Please consult our factory for more information on this product.
-
product
Waveguide Harmonic Mixer, 33 to 50 GHz
11970Q
The Keysight 11970Q waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
-
product
Digital Total Chlorine Tester
MW11
The Milwaukee MW11 Total Chlorine Photometer lets you go digital with your testing. No more hit and miss testing with strips. Great for aquariums, aquaculture & coral, labs, water conditioning , classroom and more. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
-
product
Harmonic Clam Meter
TES Electrical Electronic Corp.
Analysis for 3p4W, 3P3W, 1P2W, 1P3W. True RMS VAlue. Active Pwer. Apparent and reactive pwer. Power FActor, Phase angle.
-
product
USB Harmonic Comb Injector
J2150A
The USB Harmonic Comb Injector is a fast, easy-to-use, ultra-portable signal generator for interrogating your PDN to identify noise sensitivities. Quickly identify power supply related issues. Multiple modes include time and frequency jitter. Wideband harmonic comb spans 1kHz-1GHz+. Great for clock power supply EMI spectrum testing.
-
product
Analyzer for Total Sulfur in Gas Application
TRACE S- 1000
The ATOM TraceS-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.The Model TraceS-1000 with EUVF is a field proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability. The TraceS-1000 is an excellent fit for applications in the 0-1ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The TraceS-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.
-
product
Distortion Detector PLUS
DD-1+
The purpose of this tool is to enable the installer to set the gain of an audio amplifier to match the source unit's output level, accurately and quickly. It can also be useful for detecting distortion in the audio signal caused by poorly designed or malfunctioning audio equipment. Sets audio system gain overlap, continuously variable from 0.0dB - 15.0dB in 0.1dB steps Checks gain overlap of an audio system without making any adjustments to the existing settings Verifies that the gain overlap of an install hasn't been tampered with after install Features our Patent Pending Distortion Detection system plus digital microcontroller and our proprietary firmware
-
product
Third Harmonic Filter
HBF-T
Lifasa - International Capacitors, SA
HBF-T filters are designed to block the 3rd harmonic, reducing the neutral currents in three-phase installations where there are installed harmonic generating loads connected between phase and neutral. It is basically passive filters based on a parallel combination of inductance and capacitor.
-
product
Fuzz & Distortion Pedals
A fuzz pedal takes your sound and clips it extremely hard - known as square-wave clipping - thereby compressing the distortion to make an almost unrecognisable sound.
-
product
Total Halogen and Sulfur Analyzer
XPLORER-TX/TS*
The XPLORER-TX/TS is a microcoulometric combustion analyzer for the analysis of total halogens and total sulfur. The small footprint allows it to blend into every laboratory environment, whether it is in R & D, refinery, chemical, or petroleum applications. This next generation analyzer surpasses all others in its class in performance. It is robust, precise and ideal for harsh testing environments.
-
product
Solar Total Pyranometers
SK08 & SK08-E
The Middleton SK08 is an affordable pyranometer for the measurement of global solar irradiance on a plane surface. It meets the international accepted specifications for a good quality pyranometer. The SK08 incorporates a passive thermoelectric sensor. The SK08-E version has an inbuilt signal amplifier.
-
product
Waveguide Harmonic Mixer, 75 to 110 GHz
11970W
The 11970W extends the frequency range of the Keysight N9030A PXA high-performance signal analyzer to the W-band (75 to 110 GHz). It is also fully compatible with other Keysight spectrum analyzers including: the E4440A/46A/48A PSA (with Option AYZ), the E4407B ESA-E (with Option AYZ), the 856xEC, the 8566B (with a preamplifier), and the 7000 modular analyzer (with the 70907A/B external mixer interface module).
-
product
Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer
8100 C
Kusam Electrical Industries Limited
INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.
-
product
Multifunction Power & Harmonics Analyzer
KM 2100 / KM 2200
Kusam Electrical Industries Limited
Volts / Amps. / Hertz, Dips & Swell, Power / Energy. Unbalance, Monitor, Scope, Harmonic, Logger &, Interruption functions. (KM 2200). Inter Harmonics, Transient Voltage, Inrush Current, Flicker function not available in KM 2200. Frequency upto 400Hz (KM 2100); 50 / 60Hz (KM 2200). Single-phase 2W / Single-phase 3W / 3-phase 3W / 3-phase 4W. Flash memory 128MB. TF Card 8G Memory Card for long-term measuring data storage. Support USB port to connect to PC and analyze the data / screen shots copied by U-disk. Support LAN port to make the remote control available, transfer the measuring data.
-
product
Total Reflection X-ray Fluorescence (TXRF) Services
A highly surface-sensitive technique, TXRF is optimized for analyzing surface metal contamination on semiconductor wafers.
-
product
Harmonic Trap Inductors
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.