RTU
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
Intelligent RTU
ADAM-3600 Series
-
The ADAM-3600 is a new ADAM series for RTU application by leveraging IoT technology. They not only have high environmental adaptability to work in the far and wide remote station. But also the new form factor is very friendly for the installation in control cabinet.
-
Product
Remote Test Unit (RTU) Expert
RTU Series
-
VeEX’s Remote Test Units (RTU) are self-contained, scalable test and monitoring probes for communications networks. When used as part of the VeSion cloud-based monitoring system, these rackmount probes are optimized to work with a centralized server system. In addition, the probes can be operated in standalone mode via web browser.
-
Product
MODBUS RTU Test Software
-
MODBUS RTU Communication Test Program that helps users troubleshoot MODBUS RTU Communications. The software supports function codes, #3, #6 and #10(hex)
-
Product
Ethernet-GPIB-USB to Modbus RTU Interface
Model 9009
-
* All interfaces provide full control of the Modbus RTU slave devices.* Ethernet port supports VXI-11, raw socket and Modbus TCP/IP to Modbus RTU conversion. * GPIB port works with any IEEE-488.2 compatible GPIB controller.* USB port uses Microsoft supplied driver to prevent operating system change problems.* The 9009 uses a simple command set that is accessible from any port.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls. Works with Agilent, NI and Kikisui VISA libraries* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Ethernet interface protocol is fully VXI-11 compliant and does not require special PC drivers.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* OEM oriented board designed for integration inside the user's system with only one cable. On board regulator works with 5 to 15 Vdc power.* Support programs Include ICS's VXI-11 and VISA keyboard control programs and a NTML page utility for uploading your customer webpages.
-
Product
Remote Terminal Unit (RTU) Replacement
-
Schweitzer Engineering Laboratories, Inc.
Compared with typical RTUs, SEL automation controllers provide improved reliability, extended I/O contacts, and advanced automation and control for remote substations and field applications.
-
Product
Autonomous RTU
ADU-500
-
Infinite Industrial Informatics Lt
ADU-500 is an ultra low power, wireless RTU with data logging and alarming capabilities. The battery powered RTU incorporates three digital inputs, two analog inputs, one pulse counter input and multiple excitation options for powering measuring transducers. The device supports acquisition of up to 48 measurement channels, based on the popular SDI-12 communication protocol.
-
Product
Modbus Register Converter - Serial To Modbus RTU Interface
-
Translates Modbus registers and variable types from an older Modbus devices to a new Modbus device. The Model 2390 allows upgrading Modbus RTU devices without changing the system software. The 2390 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands strings when controlling Modbus RTU devices.
-
Product
TM Series Tiny DCON & Modbus RTU Data Acquisition Modules
-
The tM Series tiny compact modules communicate over Modbus RTU and DCON protocols and provide Analog and Digital I/O functions like isolated digital input, relay and open-collector output. They easily integrate with HMI, SCADA, PLC’s and other systems. They are equipped with two removable terminal block connectors for easy wiring.
-
Product
8DI/8DO Modbus RTU Remote I/O
ND-6150
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
Ethernet To Modbus RTU Minibox™ Interface
-
ICS's Model 9099 Ethernet to Modbus RTU Interface is a small Minibox™ Ethernet Modbus Converter that converts Modbus TCP/IP, VXI-11 and Raw Socket to control Modbus RTU Slave Devices. The Model 9099 does not require special drivers and is compatible with the following systems: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX, Windows 2K or later and Modbus capable PLCs. ICS's 9099 uses VXI-11 RPC calls for secure communication with virtually any computer. Easily programmed on a PC by making VISA calls or on a MAC/UNIX/LINUX computer with RPC calls. Special drivers are not required. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11 Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.
-
Product
M-7000 Modbus RTU Remote Data Acquisition Modules
-
M-7000 data acquisition remote I/O modules are similar to our I-7000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
Ethernet, GPIB And USB To Modbus RTU Interface Board
-
ICS's Model 9009 is a multi-interface board that allows Ethernet, GPIB or USB control of Modbus RTU devices. The Ethernet port has VXI-11 protocol for easy control by the following computer systems without special drivers: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems. VXI-11 is one of the 9009's Ethernet protocols. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.
-
Product
M-6000 Modbus RTU Remote Data Acquisition
-
M-6000 data acquisition remote I/O modules are similar to our I-6000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
Modbus RTU Based Data Acquisition
-
Modbus RTU / RS-485 based Data Acquisition Modules in analog input, digital input, digital output and analog output configurations including current, voltage, thermistor, thermocouple, RTD, and strain gauge. They can be daisy chained together over insulated copper wires.
-
Product
ANSI X3.28 To Modbus RTU - Serial To Modbus RTU Converter
-
Designed for legacy systems where there is a need to replace older X3.28 protocol Controllers and with new Modbus RTU Controllers. The Model 2399 provides ANSI X3.28 to Modbus RTU Conversion without changing the existing system software. The 2399 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands when controlling Modbus RTU devices.
-
Product
Ethernet to Modbus RTU Interface
Model 9099
-
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
Product
Modbus RTU Rs486/232/422
-
It provides client/server communication between devices connected to different types of buses or networks. Modbus-RTU (Remote Terminal Unit) means that the Modbus protocol is used on top of a serial line with an RS-232, RS-485 or similar physical interface.
-
Product
TM Series Tiny DCON & Modbus RTU Data Acquisition Modules
-
The tM Series tiny compact modules communicate over Modbus RTU and DCON protocols and provide Analog and Digital I/O functions like isolated digital input, relay and open-collector output. They easily integrate with HMI, SCADA, PLC’s and other systems. They are equipped with two removable terminal block connectors for easy wiring.
-
Product
4 2/3 Digit Potentiometer Meter (1/32 DIN)
CS3-PM
-
CS3-PM Potentiometer Indicator has been designed with high accuracy, display, controller, remote communicationsA compact body design for small equipment, laboratory instrument, and others.Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.
-
Product
6 Digit Weighing Controller
A6-SG
-
A6-SG weighing controller has been designed with high accuracy measurement (24bit A/D), 6 digital display, flexible I/O functions and communication port for general weighing application.They are also build in 4 Relay outputs, 4 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.They was designed the tracking zero and tracking stable function in programming level. According to the system, user can set the function to get the suitable reading.According the purpose, the 4 relays can be selected individual for feeder, discharge, peak, or alarm in 7 control modes.
-
Product
8AI Modbus RS-485 Remote I/O
ADAM-4017+
-
8ch analog input(current or voltage)Protocols:Modbus RTU,ASCIIWatchdog timer to recover the system3000VDC isolation protection
-
Product
Free Modbus Device Tester Software
-
Global Multimedia Private Ltd.
This software was developed to test Information Displays made by Global Multimedia for modbus protocol compliance. It can be used to test your firmware on a serial device for Modbus RTU conformance.
-
Product
6RTD Modbus RS-485 Remote I/O
ADAM-4015
-
6ch RTDProtocols:Modbus RTU,ASCIIWatch dog to recover the system3000VDC isolation protectionWiring burned-out detection function
-
Product
Ethernet To Modbus RTU Interfaces
-
ICS's Ethernet to Modbus Interfaces provide Modbus TCP/IP to Modbus RTU serial conversion and Raw Socket (Telnet) to control Modbus RTU Slave Devices. Available in small Minibox™ and OEM board formats. OEM board has Ethernet, GPIB and USB interface ports. All Interfaces include the VXI-11 protocol for use with: LINUX, UNIX, SunOS, Apple OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems.
-
Product
Meter Test System
MTS-122
-
Kongter Test & Measurement Co., Limited
This rugged Meter Test System is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 36A). This system is particularly designed with modular structure for calibration and test of analog meter, digital meter, RTU, electrical transducer, energy meter and so on. It is operated under high functionality with user friendly interface.
-
Product
Low Power Wireless Gas Detector
CX
-
Teledyne Gas & Flame Detection
Model CX sensors are equipped with standard analog 4-20mA, and Modbus™ RTU RS-485 outputs and can be used with SmartWireless Site Sentinel CX/CXT controllers. The CX is a very low power device making it an ideal choice for a battery powered detector (optional) in applications where power is unavailable or not economically feasible.CX gas detection sensors are easily and economically deployable in both permanent and temporary installations. These low power sensor assemblies utilize electrochemical technology for a long list of toxic gases.
-
Product
OEM Sensors For Liquid Analytical Measurements
-
*Connect Sensors Directly to the OEM’s control or monitoring system*Connect Sensors via MODBUS RTU*Connect Sensors via USB*Intelligent Sensor: Stores Identity and Calibration Information*Replaceable Electrode Cartridges: Application Specific Solution*Replaceable Electrode Cartridges: Low cost of Ownership*Insertion/Submersion with adjustable gland fittings and Valve *Retractable Designs*Wide Variety of Materials of Construction for Industrial Applications
-
Product
Temperature & Humidity Transmitter
HTO
-
- CO2 measuring element: NDIR Sensor 2- CO measuring element: Electrochemical sensor- Temperature/Humidity sensing element : CMOS sensor- Analog output option:4~20mA or 0~10V- Communication output option:RS485 Modbus RTU- Configured by PC with free software via USB cable (option)- Present value offset adjustable- Inside buttons for adjust output parameters- LCD backlight color to Indicated CO/CO concentration 2- Temperature measuring range can be -50~100℃ via USB console port to setting
-
Product
5 Digit Frequency Meter
CS1-F
-
CS1-F economic type Frequency Meter is designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~100KHz(option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
Product
5 Digit Preset Counter
CS2-CT
-
The CS2-CT provides high speed and multifunction, counting, control and communication (Modbus RTU mode) of Pulse from flow meter or encoder, proximity switch, photo switch for length control.There are 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue,and RS485 port available. They are also support N, R, C mode for totalizer control.