Filter Results By:
Products
Applications
Manufacturers
Thermocouple Simulators
-
product
PXI Thermocouple Simulators
Our PXI Millivolt Thermocouple Simulator modules provide 32, 24, 16 or 8 channels of accurate low sources. They are ideal for the simulation of thermocouples and can be used for sensor emulation in ECU testing. The channels can be operated with one of three voltage ranges covering most thermocouple types. We can also supply connection solutions allowing the easy integration of the Thermocouple Simulator into your test system.
-
product
PXI Millivolt Thermocouple Simulators
Series 41-760
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
PXI Millivolt Thermocouple Simulator Module - 16 Channel
41-760-003
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Millivolt Thermocouple Simulator Module - 32 Channel
41-760-001
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
16-Channel VME Analog Output/Thermocouple Simulator Module
V470
The V470 is a 6U VME module that provides sixteen independent, isolated analog outputs that may be user-programmed to operate as voltage outputs or thermocouple simulators. Users may write temperature or voltage values at VMEbus speed, and the microprocessor will transparently do all necessary calculations and update the channel electronics.
-
product
Engine Speed Control and Measurement (Test Set A)
MS 1100
*Checks the parameters such as current, voltage, speed, and turbine gas temperature of 804E and 811 engines Portable instrument*Testing of Automatic engine control system and after burner control system*Simulates the temperature signal derived from the engine TGT (Temperature Gas Turbine) thermocouples*Simulates the speed signal, NL (low pressure shaft speed signal) drive from the L.P shaft Probe*Indicates the current signal to the FCU solenoid derived from the engine control amplifier*Measure the TGT and NL simulated signal at static position*Measure the signal produced by the engine TGT thermocouples*Measure the NL signal produced by the LP shaft*Measure the NH (High-pressure shaft speed) signal produced by HP shaft*Indicates the solenoid current, produced by the engine control amplifier*Indicates the solenoid voltage, produced by the engine control amplifier*Used to test engine in both static and dynamic states
-
product
Thermocouple Calibrators
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
Compensation Block for Thermocouple Simulator Modules
40-965-912
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Simulation Modules For Sensor Simulation
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
product
Thermocouple, Contact, ITA, Chromel, Type K (°C)
610113133
Primary mating contact 610131131.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
product
Thermocouple, ITA, 36", 24 AWG Thermocouple Wire K Type, Single Ended (3 Amps)
7-409803000-036
Thermocouple, ITA, 24 AWG Thermocouple Wire K Type (3 Amps), Twisted Pair, Single Ended
-
product
PXI Battery Simulator 2.8 Amps
41-753-001
The 41-753 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals that can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
PXI RTD Simulator Module, 16 Channel, PT500
40-263-202
The 40-263-202 is a 16-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
41-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
Synchro/Resolver Simulator, Programmable
5330A
NAI's 5330A Synchro/Resolver Simulator is a rack-mount or bench-top instrument featuring integrated touch-screen controls and input terminals. This model represents a major step forward as it uses digital technology to produce Synchro and Resolver outputs. Improved flexibility is provided by two fully independent outputs that can be used to simulate two separate Synchro or Resolver signals simultaneously, or can be combined to operate as two-speed outputs. The versatility of this device has been substantially increased by incorporating dynamic modes that enable servo systems to be tested under various simulated stringent field conditions.
-
product
PXI 6-Channel Battery Simulator Module
41-752-001
The 41-752 is a 6 channel battery simulator, each channel being capable of supplying up to 7V and 300mA to the load. Each channel is fully isolated from ground and from each other allowing the channels to be connected in series to simulate batteries arranged in a stacked architecture. The 750V isolation barrier permits the 41-752 to be used to create a lower power version of a battery stack representative of those used for vehicle propulsion.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for CPCI With 2 Or 4 CAN Bus Nodes
ACC825-3U-x
ARINC825 (CAN bus) Test & Simulation module for CPCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACC825-3U-x CPCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
Thermocouple, Contact, Receiver, Alumel, Type K (°C)
610113132
Primary mating contact 610113134.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 6-Channel PT1000
40-262-102
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel
41-752A-003
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI RTD Simulator Module, 16 Channel, PT1000
40-263-203
The 40-263-203 is a 16-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
GPS Simulator
ADIVIC MP6220
Multi-channel GPS simulator for GPS receiver position fix testIndividual channel is power adjustableSingle channel mode for receiver S/N ratio testTunable power output level from -160dBm to -55dBm





























