Current Comparators
-
Product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-45NK
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Elcometer Surface Comparators
125
-
Using the Elcometer 125 surface comparators as a reference the blasted profile can be compared to the four reference profile grades in each comparator. Profiles are recorded in microns.
-
Product
Stand-Alone Current Sensors
-
The Aanderaa Current Sensors are based on the backscatter acoustic Doppler principle.
-
Product
Current Measurements of PWM or Inverter, AC/DC 25~500A, φ35mm
CTF-500DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 25~500A*Current measurements for PWM or inverter
-
Product
Automotive Fuse Current Probe
FUSE PEEKER
-
Automotive Diagnostics and Publishing
Automotive Fuse Peeker Current Probe for Testing Injectors, Coils, Solenoids and most components. The FUSE PEEKER Automotive Fuse Current Probe works with your own scope, the Auto Scope 1 or any other type of oscilloscope. It uses magnetic sensor technology, which is accurate and safe for your tool. It can detect small amounts of current as small as 5 milli-amps.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
-
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TV
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used for measurement of DCcurrent etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x8, 2-Pole, Y Loop-thru
42-514-001
Matrix Switch Module
The 40-514-001 (PXI) and 42-514-001 (PXIe) are low density matrices in 6x8 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 12-Channel, 1-Pole
40-514-107
Multiplexer Module
The 40-514-107 (PXI) and 42-514-107 (PXIe) are low density multiplexers in dual 12-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Low Current Probe 80A
695
-
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
TMR Current Sensors
-
MultiDimension Technology Co.,Ltd.
An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.
-
Product
Split type AC Current Transformer
CTF-200T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
5 Amp High Accuracy Current Probe
HA5
-
Our HA5 Current Probe covers the measurement range from 20 milliamps to 5 amps, making it the best choice for measuring very small loads and the outputs of CT (Current Transformer) step-down circuits.
-
Product
600 Amp DC / 400 Amp AC Current Probe
DC600
-
Can measure from 5 to 600 Amps DC current for most industrial DC measurement jobsNo batteries required, because power is supplied by PowerSight. This means that the probe will not stop during a long monitoring session.
-
Product
Secondary Current Injection Test Trolley
-
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
Product
Current clamps
-
Precision ammeters determine the intensity of an electric circuit without interrupting the current flow.
-
Product
Programmable DC Current Source
Model 121
-
The Model 121 programmable DC current source is a precision instrument suitable for bench-top use or panel-mounted operation in labs, test facilities, and manufacturing environments. It provides a low-noise, highly stable source of current up to 100 mA, with convenient manual selection through 13 pre-set output levels, each representing a ten-fold change in power when attached to a resistive load. A “user” setting allows the current output to be defined anywhere within the operating range of the unit, from 100 nA to 100 mA.
-
Product
Current Probe
PA-659
-
*Maximum Current Value: +/- 150ADC, 100A RMS*1mA = 5mA, 50mA (switchable)*Rising Time: 0.7uS*Bandwidth: DC ~ 500kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
SpikeSafe DC / Continuous Pulsed Current Sources
-
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Product
Eddy Current Data Acquisition Unit
MIZ-80iD
-
The MIZ-80iD is an all-in-one integrated eddy current instrument, probe pusher, and control system that has transformed the way eddy current data is obtained.
-
Product
Current Source
M151
-
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
Product
Electromagnetic Ammeters And Voltmeters Fb-1, AC Electric Current, AC Voltage
-
ELECTROMAGNETIC DEVICES FOR MEASUREMENT OF ACTIVE VOLTAGE AND ACTIVE CURRENT.





























