Display Calibrators
reference a test pattern to adjust by.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibration Short For Digital Multimeters
34172B
Calibration Short
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
25-meter (82 feet) Sensor Cable
E1739D
Calibration Cable
The E1739D 25-meter (82 feet) Sensor Cable is used to connect E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
Ambient Temperature CalPod Module, 20 GHz
85530B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
10" In-Vehicle Smart Display With Smart Display Port2.0
TREK-306P FL
Smart Display
Vehicle-grade 10" (4:3) XGA TFT LCD with projected capacitive touchscreen, SDP 2.0 port one cable connect support longer cable length and easy connect/disconnect. Wide working temperature range (-30 ~ 70 °C), Five user-programmable function keys.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
Electronic Calibration Module
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
Mechanical Calibration Kit
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
Product
【Resistive Touch】12.1" (4:3) Modular Front Display Design Compatible With TPC-Bxxx Series
FPM-D12T-RE
Smart Display
600 cd/m² luminance with 1024 x 768 resolutionHigh durability and performance with industrial-Grade LED LCD5-Wire resistive touch technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
Electronic Calibration Module
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
Electronic Calibration Module
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Display
Signals Gallery
-
Program “Signal gallery” is used for viewing and analysis of the recorded signal (whether from HD or in remote way).
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Calibration
-
ION Science recommends that your instruments are recalibrated on an annual basis to ensure they continue to provide you with accurate, reliable results and that they maintain their extended warranty. Choose the right calibration solution from our range below.





























